25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case.10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller. (de-energized)490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case.10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller. (de-energized)490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case.10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller. (de-energized)490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case.10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller. (de-energized)490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns
25 to 85C (with no freezing and condensation)1000 VAC for 1 min. between external terminal and case50M or more (500 VDC Mega) between external terminal and case.10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller. (de-energized)490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns
0 0 100 300 400 200 500 Flow rate [L/min(ANR)] Flow rate [L/min (ANR)] IW215 Flow rate characteristics IW222 Flow rate characteristics Supply pressure: 0.7 MPa 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 0 100 300 400 200 600 500 Supply pressure: 0.5 MPa 0.25 0.2 Set pressure [MPa] Set pressure [MPa] 0.15 0.1 IP 0.05 IW IW 0 0 100 300 400 200 500 Flow rate [L/min(ANR)] Flow rate [L/min
Heat exchanger Radiating method W Water-cooled Temperature controller 007 B HED C 2 Cooling capacity Communication 003 005 007 A B RS-485 RS-232C 300 W 500 W 750 W Temperature controller Power supply 2 Single-phase 180 to 242 VAC 50/60 Hz 176 ChemicalThermo-con Series HED Main Specifications (For details, please consult our Product Specifications information.)
EX500-DX B Install the product using 2 M5 screws x 20 mm minimum with a head 9 to 11. NOTE Refer to the product catalog or SMC website (URL http://www.smcworld.com) to obtain more detailed information about product specifications. 1 3 5 7 9 11 13 15 The direct current power supply to combine should be UL1310 Class 2 power supply when conformity to UL is necessary.
If the minimum setting unit is 1 L/min, the display will change in 1 L/min steps, e.g. 10..11..12 L/min. M Minimum setting unit O Operating fluid temperature Range of fluid temperature that can be used by the product.
IZN10 IZN10 IZN10 IZN10 01 01 01 01 P P P P 06 06 06 06 Z Z Z Z B1 B1 B1 B1 IZN10 AC 01 02 11 Rc1/8 NPN P PNP 06 6 07 6.351/4) 16 6 ( 17 6.351/4() (3m) Z (10m) N IZN10-NT L DIN IZN10A002 IZN10B1 L B2 B3 DIN 01 06 ES 2 01 ES 17mm 2 2 02 3 3 11 Rc1/8 4 4 /IZS30 /IZS30 /IZS30 /IZS30-M2 M2 M2 M2 06 6: 07 6.351/4: 16 6 :( 17 6.35(1/4):() IZN10-CP(3m) IZN10-CPZ(10m) IZN10A003 NPN
Detection range.11 6-3. Cautions on installation .11 6-4. Timing chart .12 7. Exterior dimensions.12 1 1. Safety Instruction These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard by labeling "Caution", "Warning", and "Danger".
Take measures to ensure that water droplets from condensation are not splashed onto any electric parts or equipment. 11. Condensation and freezing of the directional control valve Condensation and freezing may occur in the directional control valve due to the same cause as 10. Condensation and freezing of the pilot port.
Take measures to ensure that water droplets from condensation are not splashed onto any electric parts or equipment. 11. Condensation and freezing of the directional control valve Condensation and freezing may occur in the directional control valve due to the same cause as 10. Condensation and freezing of the pilot port.
ON/OFF signal Ball valve Pressure regulator PB1313A Filter FLUID OUT Air supply source FLUID IN Solenoid Meter-out valve Circuit example 11 7.
Fig. 9 Normal output OFFt0 Fig. 10 Sequence OFF0 Fig. 11 Sequence 6. Cascade connection There are only outputs up to 10 points (6 points in the case of VXFC06A) on a single board. However, it is possible to increase the output points by cascading (multiple board connection).
Fig. 9 Normal output OFFt0 Fig. 10 Sequence OFF0 Fig. 11 Sequence 6. Cascade connection There are only outputs up to 10 points (6 points in the case of VXFC06A) on a single board. However, it is possible to increase the output points by cascading (multiple board connection).
(Take care not to scratch the O ring groove. > Step 3 O-ring Installation surface of the O-ring Body Remove the outer seal O-ring from the Body (Take care to prevent the mounting surface of O ring from being damaged ) 11 XL-OMO0001-A 6-3. Assembly Procedure Step 1 Step 2 O ring groove Clean cloth Valve Ethanol Assemble parts eliminating any dust or debris.
For detailed description of the signals, refer to the following pages. 15 (2) Internal circuit (Numbers in brackets indicates the pin numbers) (5) PWR_DC24V LF (6) PWR_GND Output signal GND (9) CTR (10) CYL (11) VAL (16) RF (17) PWR Max.
AF AR 4 - 1) 5 2) 3) 5 4) 1 ISO VG-32 2-2. 1) 2) 3) 4) 5) 6 7) 5 - 8 9) , 10) 11) 3 1) P10 [2-6.] 2) 3) 4) 5) 6) 7) (40) 6 - 2-3. 1) 1 P10 [2-6.] fR Ft N () mm 1. (MPa)=(MPa)+{(kg) 2)} X /(mm ,, 2) 3) 4) 7 - 5) 6) 7) 8) 9) 24. 1) 2) 3) 8 - 1) 2) 1.52 2 2. 2-5. ,AS 9 - 2-6. P7.1. 1.
PTFE X446 GR-F-005(5g) 1) 25 2) () 5. 11. 26 6. 12. 27 Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2012 SMC Corporation All Rights Reserved