M12 x 1.75 M10 x 1.5 M8 x 1.25 M Bore size Standard stroke (mm) 170 140 10 10 38 38 36.5 E B F KC GB D A 11 11 8.7 120 X T V M6 M6 M5 18.5 KA KB 46 46 38 PP 70 50 M12 x 1.75 M10 x 1.5 M8 x 1.25 N H GA C 1/4 1/4 1/8 40 P 100 63 30, 50,75, 100 40 78 73 58 66.5 61.5 48.5 4 4 3.5 8 100 90 120 160 1/8 1/8 1/8 7.5 200 160 20 20 11.5 11.5 9.5 96 Guide table10-MGF Air cylinder Rotary actuator Air
Thermo-chiller with exhaust from the side: Body space: W15.7in (400 mm) x D 33.3 in (845 mm) Ventilation space: 3.9 in (100 mm) 15.0 (380) HRW008-H : Body space: W15.0 in (380 mm) x D 26.2 in (665 mm) Ventilation space: 0 15.7 (400) 3.9 (100) 33.3 (845) 26.2 (665) 10.0 ft2 (0.93 m2) 5.5 ft2 (0.51m2) 98 High Performance Easy Maintenance Temperature stability: 0.54F (when a load is stable)
8.7 120 X T V 1/4 1/4 1/8 40 P 46 46 38 PP 70 50 M12 x 1.75 M10 x 1.5 M8 x 1.25 N H GA C M6 M6 M5 18.5 KA KB 100 63 30, 50, 75, 100 40 78 73 58 66.5 61.5 48.5 4 4 3.5 8 100 90 120 160 1/8 1/8 1/8 8 200 160 20 20 11.5 11.5 9.5 846 Guide Table 10-MGF Specific Product Precautions Be sure to read this before handling.
The tightening torque should be approximately 0.05 to 0.1 Nm. 8-17-11 11 Series CYP Specific Product Precautions 1 Be sure to read before handing. Operation Handling Caution Caution 1. Open the inner package of the double packaged clean series inside a clean room or other clean environment. 2.
N) 99(4) 100(4) AC DC AC/DC 60 40 1 80 60 10(1) 60 40 40 60 Maximum Minimum 10 5(2) Note 1) Dew point: 10C or less Note 2) 50 cSt or less Note 3) D, E, N, P etc. in parentheses are option symbols.
Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 VMG1-R02-300 VMG1-R02-350 VMG1-R02-400 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 01 02 03 04 05 06 07 11 12 13 21 22 23 24 1 1.5 2 2.5 3 3.5 4 1 1.5 2 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 Connection size Piping connection method Symbol Size and model no.
Without nozzle KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 VMG1-R02-300 VMG1-R02-350 VMG1-R02-400 KNH-R02-100 KNH-R02-150 KNH-R02-200 KNS-R02-075-4 KNS-R02-090-8 KNS-R02-100-4 KNS-R02-110-8 Nozzle size Nil 01 02 03 04 05 06 07 11 12 13 21 22 23 24 1 1.5 2 2.5 3 3.5 4 1 1.5 2 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 Connection size Piping connection method Symbol Size and model no.
Supply pressure: 0.7 MPa Set pressure: 0.2 MPa Flow rate: 0 l/min (ANR) Back pressure: 0.5 MPa Supply pressure: 0.5 MPa IR2000-02 IR2000-02 IR2000-02 0.204 0.5 0.2 Set pressure (MPa) Set pressure (MPa) Set pressure P2 (MPa) 0.4 0.202 Set point 0.15 0.3 0.200 0.1 0.2 0.198 0.05 0.1 0.196 0 0.2 0.1 0.4 0.3 0.6 0.5 0.8 0.7 0.9 1.0 0 100 200 300 400 0 100 200 300 400 500 600 700 Flow rate (l
HECR002: 100 to 240VAC HECR004: 100 to 240VAC HECR006: 100 to 240VAC HECR008: 100 to 240VAC HECR010: 200 to 240VAC DC output voltage of product is reduced. 2) Confirm that the heat sink and panel are free from dust.
No.EX-OMY0021 PRODUCT NAME SI unit ( device) MODEL / Series / Product Number EX430-SIL1 Table of Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product elements 9 Summary of product function 10 Installation and Wiring 11 Installation 11 Wiring 12 LED Indication, Settings and Status Monitoring 13 LED indication 13 Switch setting (Data transmission rate setting
Wiring 1) Pass them through the cable (7) in the order of cable ground (4), washer (5), rubber seal (6), and then insert into the housing (2). 2) From the terminal block (3), loosen the screw (11), then pass the lead wire (10) through, then again tighten the screw (11). Note 1) Tighten within the tightening torque of 0.5 Nm +/-15%.
12-5-4 5 2 Finger Rotary Actuated Air Gripper Series MHR2/MDHR2 30 Model/Specifications Nominal size 10 15 20 Action Double acting Gripping force (N) (1) External grip 12 24 33 58 (Effective value) at 0.5 MPa Internal grip 12 34 59 25 Finger closing width (mm) Finger opening width (mm) 10 16 19 14 Opening/ Closing stroke (Both sides) 16 28 37 22 6 12 18 8 Stroke (mm) MHZ Weight (g) (2) 100
Example) M9NL 5 m Z (Example) M9NZ MA D491 Series MHR2/MDHR2 Model/Specifications Nominal size 20 10 15 30 Double acting Action Gripping force (N) (1) External grip 33 12 58 24 (Effective value) at 0.5 MPa Internal grip 34 12 59 25 Finger closing width (mm) Finger opening width (mm) 16 10 19 14 Opening/ Closing stroke (Both sides) 28 16 37 22 Stroke (mm) 12 6 18 8 Mass (g) (2) 390 (380) 100
Nil S n Rc NPT Nil TN TF 21 22 Relief type Vacuum suction type G Cylinder stroke (mm) Rubber bumper only Model Cushion Auto switch mounting Bore size (mm) 20 25 32 40 20 25 32 40 Action Standard stroke (mm) Port size Lubrication Model Rubber Air 10-/21-CM220 10-/21-CM225 10-/21-CM232 10-/21-CM240 11-/22-CM220 11-/22-CM225 11-/22-CM232 11-/22-CM240 Relief type Vacuum suction type 1/8 25,
Nil S n Rc NPT Nil TN TF 21 22 Relief type Vacuum suction type G Cylinder stroke (mm) Rubber bumper only Model Cushion Auto switch mounting Bore size (mm) 20 25 32 40 20 25 32 40 Action Standard stroke (mm) Port size Lubrication Model Rubber Air 10-/21-CM220 10-/21-CM225 10-/21-CM232 10-/21-CM240 11-/22-CM220 11-/22-CM225 11-/22-CM232 11-/22-CM240 Relief type Vacuum suction type 1/8 25,
70 66 90 3.2 13 66 65.8 11 70 90 3.2 Note 1) The total length of B dimension is the length when the filter regulator knob is unlocked.
Note 11) Without a valve function Note 12) Metal bowl: The combination of 2 and 8 is not possible. Note 13) For thread type: M5 and NPT. This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) The digital pressure switch will be equipped with the unit conversion function, setting to psi initially.
No.5 No.6 -77No.PS-OMV0008CN-E No.7 No.8 No.8 No.9 No.10 No.11 No.12 No.13 No.14 -78No.PS-OMV0008CN-E No.
Default settings Function Default settings Page [rEF] Reference condition [Anr] Standard condition [F 0] [rEF] page 29 [Uni] Unit selection function 1 [ L] L/min [oU1] Output mode of OUT1 [HYS] Hysteresis mode [1ot] Switch operation of OUT1 [1_P] Normal output [P_1] Set value of OUT1 [100] 100 L/min [F 1] [oU1] page 31 [H_1] Hysteresis of OUT1 [ 10] 10 L/min [CoL] Display colour of OUT1
Rc(NPT)11/4 40 to 42 Nm [ oUt2] Output mode (OUT2) [ HYS] Hysteresis mode Element Description Rc(NPT)11/2 48 to 50 Nm [ 2ot] Switch operation (OUT2) [ 2_P] Normal output The switch turns on within a set flow range (from P1L to P1H) during window comparator mode. Set P1L (switch lower limit) and P1H (switch upper limit) using the setting procedure above.