SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-08-DO-00N"

Note) Do not apply rotational torque to the piston rod. q MK/MK2 RSQ/RSG Connect the shield wire to FG (frame ground).

Do not apply torque directly to the rod. Carbon steel Nickel plated Rod end nut !0 * NBR Rod seal !1 * NBR Piston seal !2 * NBR Tube gasket !3 Note 1) 12: Aluminum bearing alloy. Replacement Parts: Seal Kits Bore size (mm) Kit No. Contents CQSKB12-PS 12 CQSKB16-PS 16 Kits include items !1, !2 and !3 from the table above. CQSKB20-PS 20 CQSKB25-PS 25 *Seal kits consist of items !1, !

Caution Aluminum alloy cast (Steel tubing: Cast iron) Chromated (In case of aluminum alloy cast iron) Non-lube Piston Chromated (In case of aluminum alloy cast iron) Aluminum alloy cast (Steel tubing: Cast iron) Air-hydro Weight/Aluminum tube: Lube style (Non-lube style, Air-hydro style) (kg) Do not open the cushion valve excessively.

Adjust the opening/closing speed of the fingers with a speed controller so that they do not operate any faster than necessary. When fingers open and close faster than necessary, impact on the fingers and other parts increases, causing poor repeatability when gripping workpieces and danger of an adverse effect on the product's life. MRHQ25C P408080-3C 2.

Do NOT make upward piping. qFloat style auto drain (N.O.) 1)Use compressor with capacity more than 3.7kw{400L/min (ANR)}. 2)Set pressure more than 0.1MPa wFloat style auto drain (N.C.) 1)Compressor can be used even if energy is under 3.7kw. 2)Set pressure more than 0.15MPa wFloat style auto drain (N.C.) DO NOT pipe upwards. 1.4-13

The switches shown DO NOT come with Yoke Clips attached.

W With locking at head side With locking at rod side q Do not use a 3 position solenoid valve. Avoid using circuit with 3 position solenoid valve (especially closed center). When pressure is trapped in the port with locking mechanism, end lock is free.

The resulting impact cannot be absorbed easily, the stroke position cannot be maintained, and faulty operation may result. t Lubrication The bearing can be used in an oilless state, but when you are going to oil the bearings, do so by using a ball-cup so that no foreign matter will be mixed.

Do not over tighten the lock nut. 4.7-7 Series ML1 Basic Style Bottom side piping port size Mounting side should be processed according to the dimensions below.

Do not plug or tighten it. (P port) (A port) (R port) 5-5-11 2 Series VGA342 Made to Order Specifications: Please contact SMC for detailed specifications, dimensions and delivery.

Do not service machinery/equipment or attempt to remove component until safety is confirmed. 1) Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 4-17-4

Coil rated voltage 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 1 2 3 Electrical entry 110 to 120 VAC, 50/60 Hz T E H G Grommet (Lead wire: 300 mm) Grommet (Lead wire: 600 mm) 4 220 VAC, 50/60 Hz 5 6 24 VDC 12 VDC Grommet terminal Conduit terminal D With connector DO Without connector L With lead wire LN Without lead wire LO Without connector M With lead wire MN Without lead wire 7 240 VAC, 50/60

Make sure that dust and/or other foreign materials do not enter the valve from the unused port (e.g. exhaust port). Also, since there is a breathing port for the armature in the manual override part, do not allow accumulation of dust and/or other foreign materials to block bleed port.

Also, since there is a bleed port for the armature in the manual override, do not allow accumulation of dust and/or other foreign materials to block bleed port. Change of Electrical Entry Angle 1. Series VT317 can change electrical entry angle. (4 positions) 2.

Confirm that the sockets do not protrude from the windows on the side of the receptacle housings. Mounting screw Socket Mounting bolt VQ7-6: M5 VQ7-8: M6 Proper tightening torque (Nm) 0.08 to 0.12 Coil Receptacle Window 3-10-2 3 Series VQ7-6/7-8 Precautions 2 Be sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page 3-13-2.

Do not use any sealing agent other than seal tape. Design Warning 1. Please contact SMC when fluids other than air are used. 2. Do not supply air pressure from 2(A) port. The air will leak out from 1(P) port. 3. Since the valve allows a small volume of air leakage, it may not be suitable for holding pressure in a pressure vessel.

Do not use the plug-in KQ Series with the KJ Series, it will not hold. 2. For combinations other than the plug-in KQs, they are interchangeable. Caution Installing of tube Cut the tube perpendicularly, using caution not to damage its surface. (Use tube cutter TK-1, TK-2 or TK-3. Do not cut the tube with cutting pliers, nippers, scissors, etc.)

Single vane Adjustment range of adjustment bolt (B) Adjustment range of adjustment bolt (A) 90 162 1 25 (S): 10 (S): 10 180 161 90 90 262 3 30 180 260 90 440 7 50 180 436 22.5 90 675 20 60 180 671 Positioning pin hole Allowable Load Adjustment bolt (A) Adjustment bolt (B) Do not permit the load and moment applied to the table to exceed the allowable values shown in the table below.

Adjust the opening/closing speed of the fingers with a speed controller so that they do not operate any faster than necessary. When fingers open and close faster than necessary, impact on the fingers and other parts increases, causing poor repeatability when gripping workpieces and danger of an adverse effect on the product's life.

Do not scratch or gouge the sliding portion of the piston rod and the guide rod. Damaged seals, etc. will result in leakage or malfunction. 2. Do not dent or scratch the mounting surface of a body and a plate. The flatness of the mounting surface may not be maintained, which would cause the sliding resistance to increase. 3.