The resulting impact cannot be absorbed easily, the stroke position cannot be maintained, and faulty operation may result. t Lubrication The bearing can be used in an oilless state, but when you are going to oil the bearings, do so by using a ball-cup so that no foreign matter will be mixed.

Do not over tighten the lock nut. 4.7-7 Series ML1 Basic Style Bottom side piping port size Mounting side should be processed according to the dimensions below.

Do not service machinery/equipment or attempt to remove component until safety is confirmed. 1) Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 4-17-4

Make sure that dust and/or other foreign materials do not enter the valve from the unused port (e.g. exhaust port). Also, since there is a breathing port for the armature in the manual override part, do not allow accumulation of dust and/or other foreign materials to block bleed port.

Also, since there is a bleed port for the armature in the manual override, do not allow accumulation of dust and/or other foreign materials to block bleed port. Change of Electrical Entry Angle 1. Series VT317 can change electrical entry angle. (4 positions) 2.

Do not use any sealing agent other than seal tape. Design Warning 1. Please contact SMC when fluids other than air are used. 2. Do not supply air pressure from 2(A) port. The air will leak out from 1(P) port. 3. Since the valve allows a small volume of air leakage, it may not be suitable for holding pressure in a pressure vessel.

Single vane Adjustment range of adjustment bolt (B) Adjustment range of adjustment bolt (A) 90 162 1 25 (S): 10 (S): 10 180 161 90 90 262 3 30 180 260 90 440 7 50 180 436 22.5 90 675 20 60 180 671 Positioning pin hole Allowable Load Adjustment bolt (A) Adjustment bolt (B) Do not permit the load and moment applied to the table to exceed the allowable values shown in the table below.

Adjust the opening/closing speed of the fingers with a speed controller so that they do not operate any faster than necessary. When fingers open and close faster than necessary, impact on the fingers and other parts increases, causing poor repeatability when gripping workpieces and danger of an adverse effect on the product's life.

Do not scratch or gouge the sliding portion of the piston rod and the guide rod. Damaged seals, etc. will result in leakage or malfunction. 2. Do not dent or scratch the mounting surface of a body and a plate. The flatness of the mounting surface may not be maintained, which would cause the sliding resistance to increase. 3.

for mounting attachment) 46 58 45 45 42 26H9 + 0.052 depth1.5 0 30 Positioning pin hole 60 18 5 86 30 107 Auto Switch Mounting Groove Dimensions M5 x 0.8 (Finger opening port) 14 24 M5 x 0.8 (Finger closing port) 42 8 3 4 3 MHY2-25D2 Opening/Closing direction through-hole type 4 x 5.5 through (Hole for mounting attachment) 12 -0.005 -0.025 6 12 22.5 (Limted area for mounting attachment) Do

Do not place your fingers in the clearance between the non-rotating plate and the cylinder tube. Your fingers could get caught between the table and the cylinder tube when the piston rod retracts. If fingers are caught in a cylinder, there is a danger of injury due to the strong cylinder output, and therefore caution must be exercised. Max. 0.15 mm 2.

Do NOT make upward piping. 2. Float type auto-drain (N.C.) DO NOT pipe upwards. (ANR)}. 2) Set pressure more than 0.1 MPa. 2. Float type auto-drain (N.C.) 1) Compressor can be used even if energy is under 3.7 kw. 2) Set pressure more than 0.15 MP 14-3-14

N Nil Rc 3 1 0 14 to 60 l/min 20 to 1500 l/min 36 to 2600 l/min NPT Specifications Water/Non corrosive liquid Copper alloy Fluid Stainless steel 304 Liquid, which do not corrode stainless steel 304. Max. pressure 1 MPa 1.75 MPa Water resistance Insulation resistance 100 M (500 DC by megameter) 1500 VAC for one min.

Do not use a screwdriver with a large grip or with a tip that does not fit into the trimmer groove because this could strip the groove.

Do not use any other agent except a seal tape. q Contact SMC if using fluids other than air. w Do not supply air pressure from 2(A) port. The air will leak to 1(P) port. e Since the valve may have slight air leakage, it may not be suitable for holding pressure in a pressure vessel.

Definition of Symbols Mounting SlA Warning aConditions for mechanical operation Do not move the mechanical operation beyond the operating limit position, as this could damage the mechanical valve itself and lead to equipment malfunction. OActuator Stroke Operate the mechanism within the stroke range that has been obtained through the formula given below.

Before piping and screwing in couplings, please make sure that sludge trom pipe threading and sealing materials do not go into the pipe. When seal tape is used, tape winding should be done so that 2 threads are left untaDed on the end.

NCf,IW NCDMW 'Noie: lf ordered do rubber bumper, orcrall length docreases .25 inches. o svE' Stainless Steel Cylinder Air Cylinder Series NCM Specifications 250 PSt(17.5 kgf/cm') 8 PSI (0.5 kgf/cm'?)

Do not use fluid which corrode the wetted parts material. 2. Do not use the products for medical or food applications. 3. The applicability may vary depending on additives. Take note also of additives. 4. The applicability may vary depending on impurities. Take note also of impurities. 5. Examples of transfer liquids are shown in the table on the left.

Do not service machinery/equipment or attempt to remove component until safety is confirmed. 1) Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 3-12-6 A