Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: KST (K + S + T), Semi-Standard 1: 8 (Metal Bowl with Level Gauge), Semi-Standard 2: Standard
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: S (Pressure Switch), Semi-Standard 1: 8 (Metal Bowl with Level Gauge), Semi-Standard 2: Standard
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: 2J (2 + J), Semi-Standard 2: Standard
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: S (Pressure Switch), Semi-Standard 1: 3 (Lubricator w/Drain Cock, Exhaust Port), Semi-Standard 2: Standard
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: KSTV (K + S + T + V), Semi-Standard 1: 12J (1 + 2 + J ), Semi-Standard 2: Standard
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 04 (1/2), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release), Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40A, Thread: Rc (Rc: for Sizes 20, 30, 40; M5: for Size 10), Port Size: 04 (1/2), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 40A, Thread: Rc (Rc: for Sizes 20, 30, 40; M5: for Size 10), Port Size: 04 (1/2), Option: G (for Sizes 20, 25, 30, 40 Round Type Pressure Gauge w/Limit Indicator; for Size10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: 8 (Metal Bowl with Level Gauge), Semi-Standard 2: Standard
1 Thread size M5 01 02 03 04 M5 x 0.8 R R R R 1 8 1 4 3 8 1 2 M5 port only Note 1) AS221: Electroless nickel plated Note 2) AS221: Steel Note 3) Meter-in type: Black zinc chromated 15-9-8 2 Speed Controller with One-touch Fitting Elbow Type (Metal Body) Series AS Flow Rate and Effective Area AS321-03 AS421-04 AS221-01 AS221-02 AS121-M5 Model Tubing O.D. 12 10 10 8 6 8 4, 6 6, 8 Controlled
ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R1/8, M5 x 0.8 NPT1/8, M5 x 0.8 Rc 1/8 Symbol NPT 1/8 4 One-touch fitting R1/8, M5 x 0.8 2 1 6 One-touch fitting 5/32" One-touch fitting NPT1/8, M5 x 0.8 1/4" One-touch fitting M5 x 0.8 female thread is cut inside the pipe.
AIRLINE EQUIPMENT, AF MASS PRO, AA, AF MASS PRO M5 MODULAR (PT), 0.63137 lb
Options include a mounting bracket and set nuts for panel mounting, and a pressure gauge.? The modular design of the AR series connects with other SMC air preparation equipment., REGULATOR, MODULAR, M5, AIRLINE EQUIPMENT, AR MASS PRO, AA, AR MASS PRO M5 MODULAR (PT), 2.39253 lb
-04 AS121F-M5-03 5/32" M5 x 0.8 M5 x 0.8 8 17.3 22.2 7 9.3 22.1 9.6 4 25 25.8 22.1 28.6 9.3 17.3 AS121F-U10/32-04 AS121F-U10/32-03 5/32" 10-32UNF 10-32UNF AS121F-M5-06 AS121F-M5-05 3/16" M5 x 0.8 M5 x 0.8 11.4 21.3 26.1 7 16.5 13.5 11.7 22.9 11.6 18.1 6 AS121F-U10/32-06 AS121F-U10/32-05 3/16" 10-32UNF 10-32UNF 8 11.7 28.6 25.8 22.2 25 9.6 AS221F-01-23 AS2 1F-M5-07 20.4 16 9.3 27.5 3.2 1/4
Customers looking for a compact, light-weight, high flow valve for piloting process valves or actuator applications, need search no longer. SMC's series V100 is one of the most advanced solenoid valves in today's market. The standard V100 uses only 0.35w, which is 76% less than comparable valves.
Customers looking for a compact, light-weight, high flow valve for piloting process valves or actuator applications, need search no longer. SMC's series V100 is one of the most advanced solenoid valves in today's market. The standard V100 uses only 0.35w, which is 76% less than comparable valves.
Customers looking for a compact, light-weight, high flow valve for piloting process valves or actuator applications, need search no longer.? SMC's?series V100?is one of the most advanced solenoid valves in today's market.??The standard V100 uses only 0.35w, which is 76% less than comparable valves.??
VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the VQD1000 valves that are in contact with fluid are all copper free. The VQD series offers a remarkably quick and stable response time.
Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal heat generation. This improves performance, decreases operating costs, and allows for direct control by PLC output relays.
Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal heat generation. This improves performance, decreases operating costs, and allows for direct control by PLC output relays.