Cylinder: Auto Switch/Housing Mount, Model: Air-hydro Style, Except Ø10, Bore Size: 25mm, Port Thread: Rc (M ø10, ø15), Stroke: 200mm, Cushion: 2 Adjuster Bolts, Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder: Auto Switch/Housing Mount, Model: Air-hydro Style, Except Ø10, Bore Size: 25mm, Port Thread: Rc (M ø10, ø15), Stroke: 50mm, Cushion: 2 Adjuster Bolts, Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 35mm, Body Option: Rubber Bumper, Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Type: Standard, Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: C+M, Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Type: Standard, Bore Size: 80mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: Rubber Bumper, Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 50mm, Water Resistant: -, Port Thread: NPT, Stroke: 30mm, Action: Double Acting, Rod End: Chamfered, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<200, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Foot, Type: -, Bore Size: 25mm, Stroke: 30mm, Body Option: Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Mounting: Through-hole/Both Ends Tapped Common, Basic, Bore Size: Ø40 mm, Port Thread: NPT, Clamp Stroke: 20 mm, Rotary Direction: Clockwise, Body Option: w/Arm, Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -
Mounting: Through-hole/Both Ends Tapped Common, Basic, Bore Size: Ø63 mm, Port Thread: NPT, Clamp Stroke: 20 mm, Rotary Direction: Counterclockwise, Body Option: w/Arm, Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -
Mounting: Through-hole/Both Ends Tapped Common, Basic, Bore Size: Ø63 mm, Port Thread: NPT, Clamp Stroke: 20 mm, Rotary Direction: Clockwise, Body Option: w/Arm, Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -
Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary
Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCY2S GUIDED CYLINDER, GE, 15MM NCY2S DBL-ACT AUTO-SW
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCY2S GUIDED CYLINDER, ME, 40MM NCY2S DBL-ACT AUTO-SW
Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCY2S GUIDED CYLINDER, ME, 40MM NCY2S DBL-ACT AUTO-SW, 37.9195 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCY2S GUIDED CYLINDER, GE, 15MM NCY2S DBL-ACT AUTO-SW
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCY2S GUIDED CYLINDER, IE, 25MM NCY2S DBL-ACT AUTO-SW, 5.43807 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCY2S GUIDED CYLINDER, GE, 15MM NCY2S DBL-ACT AUTO-SW
Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy