Lock keys (refer to P9) Minimum pressure (F_1) adjusting range Maximum pressure (F_2) adjusting range 120% 100% 100% 90% 10% 0% 0% 4 0 0 0 12 10 20mA 20mA 4 0 0 0 12 10 20mA 20mA 2.5 5V 2.5 5V 5 10V 5 10V (Note1) F_1 is adjustable in a range from 0% to 90% of the rated value. (Default value : 0%0.00MPa) (Note2) F_2 is adjustable in a range from 10 to 120% of the rated value.
Heater specifications Itemsymbol XLG-25-2 XLG-40-2 XLG-50-2 XLG-63-2 XLG-80-2 Rated voltage of the heater 90 to 240 ACV Heater assembly number XL1A25-60S-1 XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-3 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc.
NOTE 1) Make the protruding parts horizontal 2) As the ejector assembly uses three O-rings, resistance will be felt for three times. (5) Insert the protruding parts of the silencer body so that they fit in the cutouts of the ejector body. (6) Rotate the silencer assembly clockwise approx. 90 degrees. 18 - 10.4 Silencer Assembly Replacement A 5 Silencer assembly 1 2 6 Refer to (1), (2), (5
. -18No.PS-OMF0007-E Manual operation Slotted locking type (Tool required) Valve opening: Turn the screw 90 clockwise using a slotted screwdriver. The valve remains open even when the screwdriver is removed. Valve closing: Turn the screw 90 anticlockwise from a valve open position to its original position.
Spanner flat 26 flat 38 43 Mounting flange Do not At the directional control equipment end of the motor output No.LZ-OM00301 B (3/3) For the emission noise reduction, ground to the protection ground If required SMC can also supply the motor output terminal cable by the The P-clip and the motor output terminal cable to be supplied by the (44) 1908-56 38 88 Hungary (36) 1-371 1343 Turkey (90
B C D 44 Mounting J ig to the piston 43 Mounting to workpiece Fem ale thread type Male thread type D o No.LZ-OM00401 B (3/3) (44) 1908-56 38 88 Hungary (36) 1-371 1343 Turkey (90) 212 221 15 12 Finland (358) 9-859 580 Portugal (351) 22 610 89 22 Denmark (45) 70 25 29 00 Poland (48) 22-548 50 85 Greece (30) 1-342 60 76 Switzerland (41) 52-396 31 31 France (33) 1-64 76 10 00 Spain (34) 945-
or less (No condensation) 10 to 60 (No freezing) 90 or less (No condensation) Between the housing and SG terminal: 50 (500 VDC) 130 (Screw mounting), 150 (DIN rail mounting) Note 1) Do not use the power supply of inrush current prevention type for the controller input power supply.
maximum offset (A + 2 x S) S F DB DA C X114 X115, X116 U B W A H T H Q PB E PA PD P (Unlocking port) PE P (Locking port) P (Relief port) (Option V only) MACM4, MACM6 MACM2, MACM10 PC PC PC PC PE P (Relief port) (Option V only) PD [mm] Dimensions Model A B C D DA DB E F H P PA PB PC PD PE Q S T U W MACM2 X114 68 74 76 10 27.4 12 34 X115 52 6 62 X116 50 4 30 46 60 64 22.5 MACM4 X114 86 90
The graphs below show the response time when the workpiece is approached at 90% distance and 0% distance (close contact). (*: The switch point is 100% distance.) (Example: When the switch point is set to 0.1 mm, the response time when the workpiece is at 0.09 mm and 0 mm are measured.)
For models without this function, only MPa or kPa is available for the ISE70G/ISE75G, and only MPa is available for the ISE76G/ISE77G. *4 The response time indicates when the set value is 90% in relation to the step input. *5 The configuration file can be downloaded from the SMC website, http://www.smcworld.com * Products with tiny scratches, marks, or display color or brightness variations
IZN IZF ZVB IZD IZE IZH Removal of emitter cartridge 1) Rotate the cartridge 90 degrees in the counter-clockwise direction. 2) Pull to remove.
113 136 158 IN 170 34 51 68 85 102 119 20 (16 x 2) 8 OUT 402 80 121 161 201 241 281 IN 302 60 90 121 151 181 211 25 (20 x 2) 10 OUT 628 126 188 251 314 377 440 IN 471 94 141 188 236 283 330 32 (25 x 2) 12 OUT 982 196 295 393 491 589 687 IN 756 151 227 302 378 453 529 40 (32 x 2) 16 OUT 1608 322 483 643 804 965 1126 IN 1206 241 362 483 603 724 844 50 (40 x 2) 18 OUT 2513 503 754 1005 1257
113 136 158 IN 170 34 51 68 85 102 119 20 (16 x 2) 8 OUT 402 80 121 161 201 241 281 IN 302 60 90 121 151 181 211 25 (20 x 2) 10 OUT 628 126 188 251 314 377 440 IN 471 94 141 188 236 283 330 32 (25 x 2) 12 OUT 982 196 295 393 491 589 687 IN 756 151 227 302 378 453 529 40 (32 x 2) 16 OUT 1608 322 483 643 804 965 1126 IN 1206 241 362 483 603 724 844 50 (40 x 2) 18 OUT 2513 503 754 1005 1257
-20 FAX: 67-12-90-21 NEW ZEALAND SMC Pneumatics (New Zealand) Ltd. 8C Sylvia Park Road Mt.Wellington Auckland, New Zealand TEL: 09-573-7007 FAX: 09-573-7002 BELGIUM (Distributor) SMC Pneumatics N.V.
-20 FAX: 67-12-90-21 NEW ZEALAND SMC Pneumatics (New Zealand) Ltd. 8C Sylvia Park Road Mt.Wellington Auckland, New Zealand TEL: 09-573-7007 FAX: 09-573-7002 BELGIUM (Distributor) SMC Pneumatics N.V.
FGF-OP05 Hexagon nut d FGF1-20 16 40 71 31.5 400 R d1 FGF3-40 AI-3S M20 20 50 90 40 500 FGF5-60 S Note) 3 foundation bolts are required per filter unit. If ordering only foundation bolts, order 3 bolts using the above part number.
The dust retention amount of the 0.2 m version is 90 g.
HOW Replacement Element Part No. 74 m (200 mesh) 105 m (150 mesh) 149 m (100 mesh) Element size Port size (Nominal size) 04 (1/2B) 06 (3/4B), 08 (1B) 10 (1 1/4B), 12 (1 1/2B) 16 (2B) 20 (2 1/2B), 24 (3B) 28 (3 1/2B), 32 (4B) 65 x 90 85 x 110 100 x 160 120 x 180 140 x 200 180 x 260 EM001H-074N EM101H-074N EM201H-074N EM301H-074N EM401H-074N EM501H-074N EM001H-105N EM101H-105N EM201H-105N EM301H
Peltier-type Chiller Thermo-con/Rack Mount Type Air-cooled Water-cooled Reduced by approx. 90% (UL Standards) Exhaust heat 2500 W The water-cooled type has been added. (800 W, 1.2 kW) Exhaust heat 250 W RoHS Reduces the amount of exhaust heat by 90% Suppresses rises in the ambient temperature 1.2 kW type Water-cooled 1 kW type Air-cooled Space-saving design with reduced height 267 mm 221
the library HEF002 Noise level range External unit of a home air conditioner (close distance) or in a quiet office 50 dB Normal In a moving car, normal conversation, or in a department store 60 dB In a car driving at high speed, in a noisy office, or the sound of cicadas (close distance) 70 dB Noisy On a running train, ambulance siren (close distance), or inside a pachinko parlor 80 dB 90