10 17 39 24 30.6 22 D Applicable tube 46 19 12 18.6 60 81 113 10 24.9 22 M A L 10 12 33.2 29.4 16 24.6 20.8 Connection thread (with sealant) Reference dimensions after installation of R thread Note 1) D is maximum diameter.
92 108 10 10 14 14 5 5 6 6 Note) Floating brackets are shipped as a set of left and right brackets.
MXQ12-10 MXQ12-10 MXQ12-10 MXQ12-10 0.01 0.02 0.004 0 0 0 160 40 80 120 20 40 60 80 100 20 40 60 80 100 Load (N) Load (N) Load (N) 8-5-12 13 Air Slide Table Series MXQ Table Displacement due to Pitch Moment Load Table Displacement due to Yaw Moment Load Table Displacement due to Roll Moment Load Displacement at A when a load is applied to F with the slide table retracted.
B-1 A-1 B-2 A-2 B-3 A-3 B-4 A-4 Connector D terminal no. 12 13 7 6 9 8 11 10 3 Circuit Cable color Shield Vcc GND A A B B Z Z Brown Black Red Black Orange Black Yellow Black Connector B terminal no.
23.5 28 ( ): Single acting, spring return 16 Series CUJ Auto Switch: Proper Mounting Position (Detection at Stroke End) D-F8 D-M9/M9W When detecting extended stroke end When detecting retracted stroke end 10 mm or more 10 mm or more Note 2) A B A B Stroke A + Stroke B D-F8 D-M9/M9W Bore size (mm) Double acting Single acting A B Single acting Double acting A B A B A B 6 8 10 12 16 20 1
Connector C Actuator side (8) (Terminal no.) 1 2 5 6 (14) (18) A1 B1 (13.5) Cable length (L)[m] 1 3 5 8 A B C (17.7) (17.7) 1 2 1.5 3 5 8 A6 B6 (30.7) Connector A 15 16 (14.7) Connector D L (11) (10) 10 8 A B C LE-CP/Cable length: 8 m, 10 m, 15 m, 20 m ( Produced upon receipt of order) Controller side 15 (14.2) Connector C (Terminal no.) 1 2 5 6 20 (5.5) (6.3) Actuator side (14) (18) (Terminal
Never mount a switch in a place that will be used as a step stool during piping. Damage may occur if an excessive load is applied to the switch. 10. Be sure to allow straight pipe length that is minimum 8 times the port size upstream and downstream of the switch piping.
Connector C Actuator side (8) (Terminal no.) 1 2 5 6 (14) (18) A1 B1 (13.5) (17.7) (17.7) Cable length(L)[m] 1 3 5 8 A B C 1 2 1.5 3 5 8 A6 B6 (30.7) Connector A 15 16 (14.7) Connector D L (11) (10) 8 A B C LE-CP/Cable length: 8 m, 10 m, 15 m, 20 m (Produced upon receipt of order) Controller side 10 (14.2) Connector C (Terminal no.) 1 2 5 6 15 (5.5) (6.3) Actuator side (14) (18) (Terminal
Cover (Option) Port A size No. of Port A Porting Port A Port B Model Port B size 10 tube 12 tube Rc Rc 6 tube 8 tube 6 tube 8 tube KRM11 One-touch fitting One-touch fitting 6, 10 1 4 3 8 KRM12 One-touch fitting Rc female thread 6, 10 Applicable Tubing Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800)
N 7 7 Pad diameter ZX Material 12 12 Y Y 10 N 10 NBR ZR 13 S 13 Silicon rubber A A 16 U 16 Urethane rubber B B ZM F Fluoro rubber GN ZPUT ZPCT Conductive NBR Pad type ZH GS Conductive silicon rubber UT Thin flat Dimensions (mm) Dimensions (mm) CT Thin flat with ribs ZU A A B B Y Y Model Model ZP10UT ZP10CT 10 10 11 11 1 0.8 ZL ZP13UT ZP13CT 13 13 14 14 1.5 1 ZP16UT ZP16CT 16 16 17 17 ZY ZQ
For example, in the case of ITV2050 (0.9 MPa), a 50% input (0.45 MPa) creates a detectable range of 0.36 to 0.54 MPa. Set pressure ITV ITV 10% IC 5 sec. ITVX ON OFF Alarm output PVQ 0 100 Input signal (% F.S.) VEF VEP Figure 1. Alarm output range Figure 2.
less 24 VDC (10 to 28 VDC) Load current 40 mA or less 2.5 to 40 mA Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less 100 A or less at 24 VDC Current leakage 0.8 mA or less Operating position .
During Auto tuning Auto tuning failure A T 1 E R R 1 9 P V < 2 3 . 0 C # 1 A T F a i l u r e A u t o T u n i n g M O D E S h u t O f f C a n c e l : A T k e y <4> External sensor sampling cycle setting: Mode indication External Sensor Sampling Cycle. Default value: 180 sec. Setting range 10 to 999 sec.
is required. 7.5 40 Work load [kg] Work load [kg] 30 5 LEJS40;A LEJS40;A 20 AC Servo Motor Specific Product 2.5 10 0 0 0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200 Speed [mm/s] Speed [mm/s] LEJS63/Ball Screw Drive Horizontal Vertical 90 20 LEJS63;B LEJS63;B 80 70 Precautions LECS; 15 60 Work load [kg] Work load [kg] 50 10 40 LEJS63;A LEJS63;A 30 5 20 10 0 0 0 1200 200 400 600
RESET button 3.6(Mounting hole) SET button 18.7 19 10 1 22.6 ZMA 2 x R1.8 3.6 2 x R1.8 (Mounting hole) (Mounting hole) (Mounting hole) 17.8 1 10 ZQ 19 Pilot valve for supply Release valve ZH Adsorption confirmation switch ZU Release flow rate 2 x 3.3 (Mounting hole) Interface plate adjusting needle A Vacuum port (V) ZL A Vacuum port (V) M5 (or M6) ZY Pitch = 10 M2.5 x 63 Philips screw Air
M6 X 1 thread 6.5 deep 5H9 5 deep +0.030 0 MGP 5H9 5 deep +0.030 0 HA GA NN-M6 X 1 thread 12 deep MGQ 6 A B MGG 1.5 30 MGC 11 11 5.1 9.5 MGF A B 29 11.5 29 11.5 CY1 H (NN-1) X H G Cross section AA Cross section BB MY1 (mm) Model F 50 50 50 60 35 60 70 70 80 Z 81.5 81.5 81.5 91.5 106.5 145.5 198.5 252.5 304.5 K 31 41 51 61 71 96 121 146 171 J 44 44 44 54 69 108 113 155 190 I 10 10 10 10 10
DB, E MLGPM (slide bearing)/Dimensions A, DB, E (mm) (mm) A E A E Bore size (mm) Bore size (mm) DB DB st50 50
DB, E MLGPM (slide bearing)/Dimensions A, DB, E (mm) (mm) A E A E Bore size (mm) Bore size (mm) DB DB st50 50
0.05 0.05 MK(2) Standard Stroke RS Q G Bore size (mm) Standard stroke (mm) RS H A 10, 16 5, 10, 15, 20, 25, 30 20, 25, 32 5, 10, 15, 20, 25, 30, 40, 50 RZQ Precautions MI W S CEP1 Be sure to read before handling.