sub plate None With surge voltage suppressor With light/surge voltage suppressor (D type only) Nil S W Z E Please inquire separately regarding applicable voltage.
Bracket (ZS-33-M) Bracket (ZS-33-MS) -37No.PF-OMJ0016-J Lead wire and connector (ZS-33-D) Connector cover (ZS-33-F) -38No.PF-OMJ0016-J Revision history A: Contents revised in several places. B: Contents revised in several places. C: Modified errors in text. D: Contents are added. E: Contents revised in several places. F: Contents revised in several places.
Output specifications ZSE ISE 21 NPN open collector 2 outputs without analog output ZSP 22 NPN open collector 2 outputs with analog output (1 to 5 V) PS Positive pressure ISE3 ISA PSE Vacuum ZSE3 IS ISG Suffix Nil None ZSM D For replacement with ZX series Note 3) Compliant with piping specifications OX and OXY only.
Description Material Model Bore size (Nominal size B) FNR100 N V-10 FNR101 N V-10 1 2 3 Stainless steel SUS304 Cover 194 (257) Rc 1 Stainless steel SUS304 Bowl 332 (385) Stainless steel SUS304 V-band Note Parts list Note Replacement parts No. Description Material No.
V O Speed max 10ms ON OFF BUSY BUSY ON OFF max 60ms V O Speed Response time with respect to controller input signals Timing for alarm reset The following requisites exist for delay of response with respect to controller input signals.
K M H 2-4.5 mounting hole D N-FA Applicable tubing O.D. MS T VMG Applicable tubing O.D.
V O Speed Max. 10ms ON OFF BUSY ON OFF BUSY Max. 30ms Max. 60ms V O Speed Timing for alarm reset Response time with respect to controller input signals ON OFF ALARM -RESET Max. 5ms The following factors exist for delay of response with respect to controller input signals.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-15 Connection of RS-232C HRS Series 3.3Installation 3-27 HRX-OM-S004 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
Auto switch Auto Switch Specifications D-M9N-5(With indicator light) Auto switch model D-M9N-5 Electrical entry direction In-line Wiring 3-wire Output NPN type Applicable load IC circuit,Relay,PLC Power supply voltage 5 , 12 , 24 VDC (4.5 to 28 V) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less
D-X Individual -X 261
Lead wire Hook Caution Plug Connector Lead Wire Length Gently operate locking manual override styles B, D using small screwdriver. [Torque: 0.1Nm or less] Standard length is 300mm, but the following lengths are also available.
D-A9V/M9V/M9WV/D-M9A(V)L types cannot be mounted. Do not indicate suffix N for no lead wire on D-A3/A44/G39/K39 models. -X Lead wire length symbols: 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN Individual -X Since there are other applicable auto switches than listed, refer to page 1214 for details.
SYJ3000T Series Q 12, 24DC Coil rated voltage V Q Starting 0.55 Power consumption W Electrical circuit (For power saving type) Holding 0.22 Red (+) Specifications other than above are the same as standard models.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-17 Connection of RS-232C HRS090 Series 3.3Installation 3-27 HRX-OMT002 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
(With NPN output) 1 V or less (With load current of 80 mA) 1 s (0.25, 0.5, 2, 3) Yes 1% F.S.
(With NPN output) 1 V or less (With load current of 80 mA) 1 s (0.25, 0.5, 2, 3) Yes 1% F.S.
EX120-SMJ1 EX121-SMJ1 -32No.EX-OMB0014-H EX122-SMJ1 EX124D/U-SMJ1 -33No.EX-OMB0014-H EX126D-SMJ1 -34No.EX-OMB0014-H Revision history C: Complete revision D: Terminal screw change Switch cover change (EX124U/D, EX126D) E: Modified errors in text.
Signal name Details 1 L+ 24 V (Control and input) 2 P24 24 V (Output) 3 L0 V (Control and input) 4 C/Q IO-Link communication, Digital input (PNP) or Digital output (PNP) 1 5 N24 0 V (Output) 1: Can be changed with parameters. Digital output power supply is used for control / input. The relationship between connector No. and IO-Link port is shown below. Connector No.
Point for measure Point for measure Offset voltage (V) Discharge Offset voltage(V) Discharge time (s) time (s) ment ment (1) 1.3 0.20 (1) 0.0 0.19 (2) 2.5 0.34 (2) 0.6 0.40 Notes: When additional air flow pressure is set to 0.2MPa and supply pressure to the dust collector to 0.3MPa.