This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 1X, IFW OTHER SIZE(MISC./OTHER), .57320 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM71192%8%2 to 100 l/min2 to 105 l/min0 to 105 l/min5.00 V20.0 mA
SMC's PFM dual color digital flow switch was?developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.? The series is incredibly compact and lightweight compared to existing flow sensors.??The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 1X, IFW OTHER SIZE(MISC./OTHER), .60626 lb, ModelGas ratioRated flow rangeDisplayable rangeSettable rangeMax. analog output ArCO2Voltage (Vmax)Current (Imax)PFM75092%8%1.0 to 50.0 l/min1.0 to 52.5 l/min0 to 52.5 l/min5.00 V20.0 mA
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 1X, IFW OTHER SIZE(MISC./OTHER), 0.33069 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DA, IFW/PFW 1/4INCH PT VERSION, 0.3765 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CA, IFW/PFW 1/8INCH PT VERSION, 0.48905 lb
SMCs new PFMB dual color digital flow switch allows for a wide range of flow measurement with one product.? The PFMB is suitable for use with air and nitrogen.? Its compact and space saving with an integrated flow adjustment valve.? The bypass structure?limits the contact of moist air with the sensor, reducing degradation?of the sensor and helps maintain accuracy.? 2-color display improves
SMC's PFM dual color digital flow switch was?developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.? The series is incredibly compact and lightweight compared to existing flow sensors.??The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Body Size: 30, Thread: Rc, Port: 03 (3/8), Option: D [Float Type Auto Drain (N.O.)], Attachment: V1 (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: Standard, Semi-Standard 2: R (Flow Direction: Right->Left)
Body Size: 30, Back Flow: w/o Backflow, Thread: Rc, Port Size: 03 (3/8), Options: D (N.O., Normally Opened), Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: Polycarbonate Bowl, Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: R (Flow Direction: Right to Left), Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa, °C; Pressure Gauge: MPa
Model: 10S (Side Ported), SI Unit Specification: VB (CC-Link, 16 Outputs, M12 Connector), SI Unit Output Polarity: N (Negative Common), Valve Stations: 3 Stations, P, E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A, B Port Size: C6 (ø6 One-touch Fitting)
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: 0 (w/o SI Unit), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 3 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting), Mounting: Direct Mounting, DIN Rail Option: DIN Rail Mounting, w/DIN Rail, Combination Manifold:
Series: 3 (JSY3000), Type: 10S (Side-Ported, Serial Interface, EX260), SI Unit: QA (DeviceNetâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: NPN, Positive Common, Valve Stations: 3 Stations, P,E Port Location: D (D Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A,B Port Size: C6 (ø6 One-touch Fitting), Mounting: D (DIN Rail Mounting), DIN Rail Option: DIN Rail Mounting
The SV series employs a multi-connector instead of the conventional lead wires for internal manifold wiring. By connecting each block with a connector, changes to manifold stations are greatly simplified. Cassette base type manifolds offer the ultimate in flexibility. Manifold sections can be added using a simple release mechanism. Conventional tie-rod base type manifolds are also available
SI Unit: QW (DeviceNet), Input Block Stations: 33 (3 Stations/M8: 4 Inputs 3 Pins), Input Block COM: N (-COM), Stations: 3 Stations, SUP/EXH Block Mounting: D (D Side 2~10 Stations), Pilot: Internal Pilot, A, B Port: C4 (ø4 One-touch Fitting), Mounting Method: None, US Option: X160US (Preferred US Option for DeviceNet Type)