Function: 3 (3 Position Closed Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 2 (200VAC 50/60HZ), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping)
Function: 4 (3 Position Exhaust Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: R (External Pilot), Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping)
Function: 3 (3 Position Closed Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping), Thread: N (NPT)
Function: 3 (3 Position Closed Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping)
Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Stations: 3 Stations, Passage: 3 [P(SUP): Common, E(EXH): Individual, Port A,B(CYL): Side], Port Size: 02 (1/4), Thread: N (NPT), Control Unit: E (Air Release Valve), Voltage Air Release Valve: 1 (100VAC 50/60HZ)
Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Stations: 3 Stations, Passage: 3 [P(SUP): Common, E(EXH): Individual, Port A,B(CYL): Side], Port Size: 02 (1/4), Thread: T (NPTF), Control Unit: E (Air Release Valve), Voltage Air Release Valve: 1 (100VAC 50/60HZ)
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: 2 (90°), Thread: G (G), Port Size: 02 (1/4), Applicable Tubing O.D.: 10 (ø10)
Speed controller with residual pressure release valve with one-touch fittings, Body sizes: 1/8, 1/4, 3/8, 1/2, Elbow or universal style, Meter-in or meter-out control, Port sizes: 01, 02, 03, 04, Tube sizes O.D. (mm): 4, 6, 8, 10, 12, SPEED CNTL W/EXHAUST, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, EB, AS***F 3/8INCHSTANDARD (PT), .14237 lb
Speed controller with residual pressure release valve with one-touch fittings, Body sizes: 1/8, 1/4, 3/8, 1/2, Elbow or universal style, Meter-in or meter-out control, Port sizes: 01, 02, 03, 04, Tube sizes O.D. (mm): 4, 6, 8, 10, 12, FLOW CONTROL W/FITTING, AIRLINE EQUIPMENT, AMH MICRO MIST SEPARATOR, ED, AMH 3/8INCH STANDARD (NPT), 0.11342 lb
Speed controller with residual pressure release valve with one-touch fittings, Body sizes: 1/8, 1/4, 3/8, 1/2, Elbow or universal style, Meter-in or meter-out control, Port sizes: 01, 02, 03, 04, Tube sizes O.D. (mm): 4, 6, 8, 10, 12, FLOW CONTROL W/FITTING, AIRLINE EQUIPMENT, AMH MICRO MIST SEPARATOR, ED, AMH 3/8INCH STANDARD (NPT), 0.11342 lb
Speed controller with residual pressure release valve with one-touch fittings, Body sizes: 1/8, 1/4, 3/8, 1/2, Elbow or universal style, Meter-in or meter-out control, Port sizes: 01, 02, 03, 04, Tube sizes O.D. (mm): 4, 6, 8, 10, 12, FLOW CONTROL W/FITTING, AIRLINE EQUIPMENT, AMH MICRO MIST SEPARATOR, ED, AMH 3/8INCH STANDARD (NPT), 0.15615 lb
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, MUFFLER 3/4 PT, AIRLINE EQUIPMENT, AN SILENCER, GX, AN 3/4INCH (MISC./OTHER), .43422 lb, ModelEffective area mm2Sonic conductance C [dm3/(s?
(Standard), 10 ft. (Optional) Min. Auto Switch Mountable Strokc Relay, Sequence Parts No. of Auto Switch Mounting Band 5 150mA 3V or less 1mA Au to Sw it c h/ C ircuit Diagram D.864 -fffi^9 Bbck LFad swirch rummouEdoonce qeo r.
XRAY Page 3 xRAY-450-50/150 Note: Elght T.l.{ut. (6mnj are supplled to nDunt gdppr.
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: None (0°), Thread: R, Port Size: 02 (1/4), Width Across Flats: 9mm, Tubing: 10 (ø10)
Body Size: 2 (1/8, 14), Type: 3 (Universal), Control Type: 1 (Meter-in), Model: 1FSG, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 10 (ø10), Seal: S (with Sealant)
Function: 3 (3 Position Closed Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping)
Function: 3 (3 Position Closed Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping), Thread: N (NPT)
Function: 3 (3 Position Closed Center), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 02 (Base Mounted w/Sub-plate 1/4 Side Piping), Thread: T (NPTF)
Model: 2 (10-SV2000), Actuation: 3 (3 Position Closed Center), Pilot Type: R (External Pilot), Rated Voltage: 5 (24 VDC), M12 Waterproof Connector: W1 (300mm), Light/Surge Voltage Suppressor: U (With Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: N (NPT)