Rated Pressure Range: 1 to -101 kPa, Piping: NPT1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Initial Value PSI, Option 2: w/Bracket Rear Ported Only, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: NPT1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: 1 to -101 kPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: Initial Value PSI, Option 2: w/Bracket Rear Ported Only, Option 3: -, X Options: -
IP40 050 -1070 () 3585% RH() AC1000 V50/60Hz1 5 M(DC500 V) 2%F.S.(25 ) 3 2.7 3 m / 2 0.15 mm 0.8 mm CERoHS M5 R06 R07 M50.8 6 1/4 inch ONBR SUS304 PBT (3 m) 41 g 38 g 7 g 3.8 g -12No.PS-OME0003CN-F [V] A B C 0-101kPa 0 -101 kPa 10.1 kPa -101101kPa -100 kPa 101 kPa 0101kPa 0 101 kPa -10.1 kPa -01MPa 0 1 MPa -0.1 MPa -13No.PS-OME0003CN-F PSE53-M5 PSE53R06 R07 (D) PSE53-
Type: 101 (Smart Rotary Type), Pressure Gauge: 3 (1.0 MPa), Specifications: 3 (w/ HART Transmission Function), Accessories: None (Standard), External Scale Plate: H (w/External Scale Plate), LCD Window: None, Connection, Air - Electric: 3 (NPT1/4 - NPT1/2)
Type: 101 (Smart Rotary Type), Pressure Gauge: 3 (1.0 MPa), Specifications: 3 (w/ HART Transmission Function), Accessories: None (Standard), External Scale Plate: None, LCD Window: W (Body w/LCD Window), Connection, Air - Electric: 3 (NPT1/4 - NPT1/2)
Type: 101 (Smart Rotary Type), Pressure Gauge: 3 (1.0 MPa), Specifications: 3 (w/ HART Transmission Function), Accessories: D (Fork Lever-type Fitting S), External Scale Plate: H (w/External Scale Plate), LCD Window: W (Body w/LCD Window)
Type: 101 (Smart Rotary Type), Pressure Gauge: 3 (1.0 MPa), Specifications: 3 (w/ HART Transmission Function), Accessories: None (Standard), External Scale Plate: None, LCD Window: W (Body w/LCD Window), Connection, Air - Electric: N (Rc1/4 - NPT1/2)
Type: 101 (Smart Rotary Type), Pressure Gauge: 3 (1.0 MPa), Specifications: 0 (Basic), Accessories: D (Fork Lever-type Fitting S), External Scale Plate: None, LCD Window: W (Body w/LCD Window), Connection, Air - Electric: 2 (NPT1/4 - M20x1.5)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Connector Type: S (M12 Connector Type)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)