SMC Corporation of America
Elite Part Number Search
Search Results "LVM11-5A-1-10-Q"

blank plate assy, SY5000 SOL/VALVE, RUBBER SEAL*** $3.81 + Add to Quote Add To Cart Add to Cart SMC SY5000-GS-1 gasket set (1 pkg = 10 gaskets, SY5000 SOL/VALVE, RUBBER SEAL*** $6.07

+ Add to Quote Add To Cart Add to Cart SMC SY5000-GS-1 gasket set (1 pkg = 10 gaskets, SY5000 SOL/VALVE, RUBBER SEAL*** $6.07 + Add to Quote Add To Cart

Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: L (Out 1: IO-Link: Switch Output, N/P, Out 2: None; Temperature Sensor ), Temperature Sensor: T (Temperature Sensor), Lead Wire: Q (w/M12-M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket

OTo reuse the lubing, cut off the previously lodged portion of lhe lubeOThen pull it back gently to make sure that il has a positive seal. o Rectangular Multi-Connector Series KDI/t Dimensions ..) q E a 6 L 7 4 1 . = z a 3i' -l _*r>'L ;l ann , l:i Panel mount cutout 5/32" l4mm) KDM20 .9 g 7.64" (194) | Panel mount cutout 3-hexagonal screws 5/32" l4mm) Rectangular Multi-Connector Series

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display

12316 123156 12314PA Sight dome 3 1 Lubrication plug assembly 4 1 123528A Standard Bumper assembly 5 1 Note 1) -2, -8 123528-1A Note 1) Needle stud assembly 6 1 123128PA 124232A 123321-1A 123321-4A 12318 123111 113136 KA00466 Standard -8 -1 Siphon tube assembly 7 1 Sight dome seal Siphon nut seal O-ring O-ring 8 9 10 11 12 13 Urethane rubber 1 1 1 1 1 1 Urethane rubber NBR NBR Bumper retainer

Conforms to ISO 15407-2 Standard 5 Port Solenoid Valve/Plug-in Type Series VS 8-2/VS 8-4 S R S R [Option] How to Order Manifold 03 SD6Q VV8 01 N 1 1 N 5 W1 Size 01 02 Size 26 mm Size 18 mm CE compliant Nil Q CE compliant Stations 1 1 station Option Nil None 16 16 stations Special wiring specifications (Except double wiring) K Cylinder port size Direct exhaust with built-in silencer S Symbol

NCmRO-OT NCI|RO-OS H3 ).250 | r-24 o.75 |.0010.621 r2s6;; 093t0.22 t0-32 uNFl0.8l L00 1 . 1 20.12 t10-32 UNF $-m 0.62 0.34 0.880.38 3.22 2.66 2.35 1.69 t.312tyt -24 003t025 O-32UNF .12 r25 1.47 0.2,1 llG32 UtlF 1A-20 0.s10.47 1.22 o.62 3.75 3.34 2-93 1.81 ).137 t%^-20 r.25 1.m).12510-38 | r. -20 UNC 't.75 1.93 0.25 t|l-20 LhrC x.-18 1 . 1 20.38 1.57 0.88 4 . 1 9 3.49 3,692.O0 slrc' Air Cvlinder

Symbol: 105R (Base Mounted, 3 Port, Universal), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 105R (Base Mounted, 3 Port, Universal), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 102R (Body Ported, 3 Port, Universal, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R1 (Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R2 (Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R2 (Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 10 (1000mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 10 (1000mm)