Driver Type: AN (Pulse Input Type, NPN), I/O Cable Length, m: 1 (1.5), Driver Mounting: Screw Mounting, Type: Y (Miniature Rod), Size: 6, Motor Size: Standard, Lead Screw Type: K (Size 6: 4; Size 10: 5), Stroke: 25mm

A 60% ethylene glycol aqueous solution (10 L) can be ordered using the part number “HRZ-BR001.”
When using with an HRS series thermo-chiller, use tap water to create a 4:1 ratio of water to solution.

Table Accuracy: Basic, Size: 10, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: 2 (External Stopper: 180°), Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: 1 (1.5), Controller Type - LEC, JXC: AN (LECPA, Pulse Input Type, NPN), I/O Cable Length for LEC: 1 (1.5)

Table Accuracy: Basic, Size: 10, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: 2 (External Stopper: 180°), Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5), Controller Type - LEC, JXC: AN (LECPA, Pulse Input Type, NPN), I/O Cable Length for LEC: 1 (1.5)

Size: 10, Motor Size: Standard, Lead Screw Type, mm: J (LEPS6: 8; LEPS10: 10), Stroke: 50mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: S (Standard Cable), Actuator Cable Length, m: 1 (1.5), Controller Type - LEC, JXC: AN (LECPA, Pulse Input Type, NPN), I/O Cable Length for LEC: 1 (1.5), Controller Mounting: D (DIN Rail Mounting, DIN Rail not Included)

Size: 10, Motor Size: L (Compact Type), Lead Screw Type, mm: J (LEPS6: 8; LEPS10: 10), Stroke: 50mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: None, Actuator Cable Length, m: No Cable, Controller Type - LEC, JXC: AN (LECPA, Pulse Input Type, NPN), I/O Cable Length for LEC: 1 (1.5), Controller Mounting: D (DIN Rail Mounting, DIN Rail not Included)

SMCs horizontal type LEHF, 2-finger electric grippers are structured to maintain workpiece gripping force in the event of an emergency stop or restart.á An encoder makes it possible to confirm positioning and to output length measurements.á The LEHF series is available in standard or long stroke models.2-finger type, Body size: 10, 20, 32, 40, Manual override adjustment screw on both sides

SMCs horizontal type LEHF, 2-finger electric grippers are structured to maintain workpiece gripping force in the event of an emergency stop or restart. An encoder makes it possible to confirm positioning and to output length measurements.

Stations: 10, Systems, Port Combinations: AN [Ejector System, ø5/16" (Common PV)], Exhaust: 1 (Complex Exhaust), Wiring: F (D-sub Connector), Bracket: B (w/DIN Rail Mounting Bracket), Common Release Pressure Supply: w/o Option, Manifold Individual Supply: w/o Option

Stations: 10, Systems, Port Combinations: AN [Ejector System, ø5/16" (Common PV)], Exhaust: 2 (Individual Exhaust), Wiring: F (D-sub Connector), Bracket: B (w/DIN Rail Mounting Bracket), Common Release Pressure Supply: w/o Option, Manifold Individual Supply: w/o Option

Stations: 10, Systems, Port Combinations: AN [Ejector System, ø5/16" (Common PV)], Exhaust: 1 (Complex Exhaust), Wiring: N (No Wiring, No Valve), Bracket: w/o Option, Common Release Pressure Supply: w/o Option, Manifold Individual Supply: L (Manifold Individual Supply Specification)

Stations: 10, Systems, Port Combinations: AN [Ejector System, ø5/16" (Common PV)], Exhaust: 2 (Individual Exhaust), Wiring: N (No Wiring, No Valve), Bracket: w/o Option, Common Release Pressure Supply: w/o Option, Manifold Individual Supply: L (Manifold Individual Supply Specification)

Driver Type: AN (Pulse Input Type, NPN), I/O Cable Length, m: 3, Driver Mounting: D (DIN Rail Mounting), Table Accuracy: Basic, Size: 10, Max Rotating Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 3 (External Stopper: 90°)

Stations: 10, Systems, Port Combinations: AN [Ejector System, ø5/16" (Common PV)], Exhaust: Individual Exhaust, Wiring: D-sub Connector, Bracket: w/o Option, Common Release Pressure Supply: D [w/Common Release Pressure Supply (PD) Port], Manifold Individual Supply: w/o Option

For the current/voltage type, 10-bit digital input, and 16-point preset input type ITV1000/2000/3000 series electro-pneumatic regulator, the error contents are indicated in the operation manual.
Refer to the ITV standard type (refreshed product) operation manual. Although this product is a 0 to 5 VDC input signal type, error 1 occurs when an input signal exceeding 5 V is supplied.

The mechanically jointed rodless cylinders leaks air externally due to its seal construction. With a closed center valve, stop positions cannot be held due to the air leakage. To perform intermediate stops, use 2 3-way valves for double-sided pressurization or use a 3-position pressure center valve as a double-sided pressurization control circuit.
https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=actuators&fa_id=10099

The ZH□-□-X185 vacuum flow can be used to suction machining chips, particles, etc.
By simply supplying compressed air, large flow rate vacuum and blowing greater than the supply volume is possible.
The ZH□-□-X185 vacuum flow features a discharge flow 4 times the supply air volume and suction flow 3 times the supply air volume.
The ZH□-□-X185 catalog can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=vacuum-products&fa_id=10277

It is available via special order. For details, refer to the following.
① When there is no piping rotation stopper, the part numbers are as follows: IRV10-01/02□-X3 and IRV20-02/03/04□-X3.
② When there is a piping rotation stopper, the part numbers are as follows: IRV10-01/02□-X28 and IRV20-02/03/04□-X28.
The IRV10 series catalog can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=vacuum-products&fa_id=10278


6) Compressed air supply capacity: L/min (ANR)
Select an IDG series air dryer according to the “How to select model” section in the IDG series catalog.
Note that the purge air flow rate described in the catalog also includes the air flow rate that flows through the dew point indicator.