SMC Corporation of America
Elite Part Number Search
Search Results "AC20B-N01C-V-12Z-D"

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 12, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread type

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 12, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: G, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 12, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 12, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 12, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: Without auto switch, Lead Wire Length(

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 12, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: G, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 12, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 12, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Without magnet, Port thread type: Rc, Auto Switches: Without auto switch

SMCs new AC series of modular type F.R.L. unit is available in 4 sizes and is interchangeable with the existing modular type AC line. The element and bowl on the AW and AF series is now one-piece, making element replacement easier. Required maintenance space has been reduced by as much as 46% on the AF series, depending on the body size. Bowls on size 30 or more are now covered with a transparent

Flow direction OUT side IN side 1: Setting is only possible for models with the units selection function. 2: 1 to 5 V or 0 to 10 V can be selected when the analogue voltage output type is used. Analogue output free range function can be selected. 3: When Line name is selected, a suitable line name can be input.

distance IZD10-510 6 From the steepest line, 25mm, 30mm, 40mm, 50mm, 60mm, 70mm, 75mm of installation distance 5 Sensor output voltage V Installation distance 25mm 4 Installation distance 75mm 3 2 1 0 4 0 3 0 2 0 1 0 0 1 0 2 0 3 0 4 0 Charged potential kV 10 6-2.

In particular, if the voltage rise rate (dv/dt) at zero crossing exceeds 40 V/200 sec, it may cause a malfunction.

Doc. no.CG1-OM0001G PRODUCT NAME STAINLESS STEEL CYLINDER MODEL / Series / Product Number C*G5*N**SR / V-* C*G5*A**SR / V-* Contents Safety Instructions P2 1. Specifications P6 1-1. Specifications 2. Installation and Handling P7 2-1. Air supply 2-2. Design 2-3. Mounting and Installation 2-4. Environment 2-5. Speed control 2-6. Cushion 2-7. Control of direction 2-8. Auto switches 3.

Type, Vacuum Pressure Sensor: D (Digital Vacuum Pressure Switch), Output Specifications: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specifications: w/Unit Switching Function, Not for Use in Japan, Lead Wire Specifications: L (Lead Wire w/Connector, 2m)

Push Type, Vacuum Pressure Sensor: D (Digital Vacuum Pressure Switch), Output Specifications: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specifications: w/Unit Switching Function, Not for Use in Japan, Lead Wire Specifications: L (Lead Wire w/Connector, 2m)

Relief valve Petroleum Water-glycol, Emulsion Phosphoric ester 0 1 2 N W V The micromesh element is a made to order specification (X0). Note) N, W and V refer to the hydraulic fluid symbol indicated at the end of the element part number.