Do not apply torque directly to the rod. Carbon steel Nickel plated Rod end nut !0 * NBR Rod seal !1 * NBR Piston seal !2 * NBR Tube gasket !3 Note 1) 12: Aluminum bearing alloy. Replacement Parts: Seal Kits Bore size (mm) Kit No. Contents CQSKB12-PS 12 CQSKB16-PS 16 Kits include items !1, !2 and !3 from the table above. CQSKB20-PS 20 CQSKB25-PS 25 *Seal kits consist of items !1, !
Caution Aluminum alloy cast (Steel tubing: Cast iron) Chromated (In case of aluminum alloy cast iron) Non-lube Piston Chromated (In case of aluminum alloy cast iron) Aluminum alloy cast (Steel tubing: Cast iron) Air-hydro Weight/Aluminum tube: Lube style (Non-lube style, Air-hydro style) (kg) Do not open the cushion valve excessively.
Adjust the opening/closing speed of the fingers with a speed controller so that they do not operate any faster than necessary. When fingers open and close faster than necessary, impact on the fingers and other parts increases, causing poor repeatability when gripping workpieces and danger of an adverse effect on the product's life. MRHQ25C P408080-3C 2.
Do NOT make upward piping. qFloat style auto drain (N.O.) 1)Use compressor with capacity more than 3.7kw{400L/min (ANR)}. 2)Set pressure more than 0.1MPa wFloat style auto drain (N.C.) 1)Compressor can be used even if energy is under 3.7kw. 2)Set pressure more than 0.15MPa wFloat style auto drain (N.C.) DO NOT pipe upwards. 1.4-13
The resulting impact cannot be absorbed easily, the stroke position cannot be maintained, and faulty operation may result. t Lubrication The bearing can be used in an oilless state, but when you are going to oil the bearings, do so by using a ball-cup so that no foreign matter will be mixed.
Do not over tighten the lock nut. 4.7-7 Series ML1 Basic Style Bottom side piping port size Mounting side should be processed according to the dimensions below.
Do not service machinery/equipment or attempt to remove component until safety is confirmed. 1) Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 4-17-4
Make sure that dust and/or other foreign materials do not enter the valve from the unused port (e.g. exhaust port). Also, since there is a breathing port for the armature in the manual override part, do not allow accumulation of dust and/or other foreign materials to block bleed port.
Do not use any sealing agent other than seal tape. Design Warning 1. Please contact SMC when fluids other than air are used. 2. Do not supply air pressure from 2(A) port. The air will leak out from 1(P) port. 3. Since the valve allows a small volume of air leakage, it may not be suitable for holding pressure in a pressure vessel.
Do not use the plug-in KQ Series with the KJ Series, it will not hold. 2. For combinations other than the plug-in KQs, they are interchangeable. Caution Installing of tube Cut the tube perpendicularly, using caution not to damage its surface. (Use tube cutter TK-1, TK-2 or TK-3. Do not cut the tube with cutting pliers, nippers, scissors, etc.)
Single vane Adjustment range of adjustment bolt (B) Adjustment range of adjustment bolt (A) 90 162 1 25 (S): 10 (S): 10 180 161 90 90 262 3 30 180 260 90 440 7 50 180 436 22.5 90 675 20 60 180 671 Positioning pin hole Allowable Load Adjustment bolt (A) Adjustment bolt (B) Do not permit the load and moment applied to the table to exceed the allowable values shown in the table below.
Adjust the opening/closing speed of the fingers with a speed controller so that they do not operate any faster than necessary. When fingers open and close faster than necessary, impact on the fingers and other parts increases, causing poor repeatability when gripping workpieces and danger of an adverse effect on the product's life.
Do not scratch or gouge the sliding portion of the piston rod and the guide rod. Damaged seals, etc. will result in leakage or malfunction. 2. Do not dent or scratch the mounting surface of a body and a plate. The flatness of the mounting surface may not be maintained, which would cause the sliding resistance to increase. 3.
for mounting attachment) 46 58 45 45 42 26H9 + 0.052 depth1.5 0 30 Positioning pin hole 60 18 5 86 30 107 Auto Switch Mounting Groove Dimensions M5 x 0.8 (Finger opening port) 14 24 M5 x 0.8 (Finger closing port) 42 8 3 4 3 MHY2-25D2 Opening/Closing direction through-hole type 4 x 5.5 through (Hole for mounting attachment) 12 -0.005 -0.025 6 12 22.5 (Limted area for mounting attachment) Do
Do not place your fingers in the clearance between the non-rotating plate and the cylinder tube. Your fingers could get caught between the table and the cylinder tube when the piston rod retracts. If fingers are caught in a cylinder, there is a danger of injury due to the strong cylinder output, and therefore caution must be exercised. Max. 0.15 mm 2.
Do NOT make upward piping. 2. Float type auto-drain (N.C.) DO NOT pipe upwards. (ANR)}. 2) Set pressure more than 0.1 MPa. 2. Float type auto-drain (N.C.) 1) Compressor can be used even if energy is under 3.7 kw. 2) Set pressure more than 0.15 MP 14-3-14
Do not use a screwdriver with a large grip or with a tip that does not fit into the trimmer groove because this could strip the groove.
Do not use any other agent except a seal tape. q Contact SMC if using fluids other than air. w Do not supply air pressure from 2(A) port. The air will leak to 1(P) port. e Since the valve may have slight air leakage, it may not be suitable for holding pressure in a pressure vessel.
Before piping and screwing in couplings, please make sure that sludge trom pipe threading and sealing materials do not go into the pipe. When seal tape is used, tape winding should be done so that 2 threads are left untaDed on the end.
Do not attempt to rotate, as it does not turn Cable connection threads RC(PT) 1/4 Exhaust porl EXH (3) Port size 4-M5 x 0 8 thread depth 6mm Mounting hole 2-RC(PT) 1/4, 3/8 SUP port, OUT porl rTl|z000/3000 tleflru-Pltotllnalic Re[ula 0imeffiiolt$ ITV3OtrT Cable connector (4 wire) Cable connector (4 wire) . Do not anempt to rotate. as it does not turn.