SMC Corporation of America
Elite Part Number Search
Search Results "PVQ13-5L-08-M5-A"

System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting), Bracket: B [One Bracket for Mounting

System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting), Bracket: w/o Option, Pump System PE

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual

System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

System: P (Vacuum Pump System, Single Unit), Valves: J (Supply Valve; N.C., Release Valve; None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting)

Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 08 (ø8), Sealant: S (with Sealant), Push lock: A (Push-lock)

Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 08 (ø8), Sealant: S (with Sealant), Push lock: A (Push-lock)

Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 08 (ø8), Sealant: S (with Sealant), Push lock: A (Push-lock)

Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 08 (ø8), Sealant: S (with Sealant), Push lock: A (Push-lock)

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FC (50 to 150 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 08 (ø8), Sealant: S (with Sealant), Push lock: A (Push-lock)

Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: G (G), Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 08 (ø8), Sealant: without Sealant, Push lock: A (Push-lock)

Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: G (G), Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 08 (ø8), Sealant: without Sealant, Push lock: A (Push-lock)

Size: 205 (1/4 Standard), Control Range: FC (50 to 150 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Tube Size: 08 (ø8), Push lock: A (Push-lock)

Size: 205 (1/4 Standard), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Tube Size: 08 (ø8), Push lock: A (Push-lock)

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / -14.5 to 14.5 (100 to -100) kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]

Fluid: 0 (Petroleum), Port Size Category: A (1/2, 3/4, 1), Std. T Dimension, mm: 1 (Port 1/2-1: 310, 1 1/4-2: 385, 2 1/2-3: 560), Filtration: 105μm, Port Size: 08 (1), Pressure Indicator: None, Connection: 0 (Companion Flange)

Fluid: 0 (Petroleum), Port Size Category: A (1/2, 3/4, 1), Std. T Dimension, mm: 4 (Port 1/2-1: 520, 1 1/4-2: 685, 2 1/2-3: 850), Filtration: 105μm, Port Size: 08 (1), Pressure Indicator: 1 (Differential Pressure Indicator), Connection: 4 (S-block Companion Flange), Air Breather: C (Cap)

Body Class: 3 (Orifice Dia. ø8), Valve Type: 0 (N.C.), Applicable Tubing Size: 08 (ø8mm), Port B (OUT) Different Dia. Size: Ports A & B Same Size, Pilot Port Thread Type: 2 (M5X0.8)

Body Class: 3 (Orifice Diameter ø8), Valve Type: 0 (Normally Closed), Applicable Tube OD: 08 (ø8), Port B OUT: Ports A & B Same Size, Pilot Port: N (Body Class 3, 4, 5, 6 - NPT 1/8")