5 C-14 6.2 x 3 x 1.6 23 4 When o and !
.: AMX-OMX0019-C PRODUCT NAME Mist Separator MODEL / Series / Product Number AM20-(F, N)01 ~ (F, N)02(B, C)(-2, 6, C, J, L, R, Z)-D AM30-(F, N)02 ~ (F, N)03(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D AM40-(F, N)02 ~ (F, N)04(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D Contents Page 1. Safety Instructions 2 to 7 2. Application 8 3. Standard specifications 8 4. How to order 9 5.
(ARBQ5000-00 A B C 1 5) q AXT632-25-6 (M4 x 114) 4 Valve + Interface regulator SQ w AXT632-66-1 (M4 x 64) 2 Not necessary when mounting the sub-plate.
4 C-9 MYM50-15AK0502 GMY50 MC-16 P44 C-4 C-11.2 MYM63-15AK0503 GMY63 MC-20 P53 C-4 C-14 GMY20 GMY16 GMY25 GMY32 MYB20-15-A7164 MYB16-15-A7163 RCS-8 RCS-10 P16 P12 TMY-25 TMY-32 5.1 x 3 x 1.05 4 x 1.8 x 1.1 7.15 x 3.75 x 1.7 8.3 x 4.5 x 1.9 7 x 4 x 1.5 7 x 4 x 1.5 C-6 C-7 MYMK-20-stroke Side seal assembly Polyurethane MYMK-16-stroke MYMK-40-stroke MYMK-25-stroke MYMK-32-stroke Note) Two
(For F, L, S, T kit) VVQ4000 3A 1 VVQ4000 2A 1 Electrical entry Electrical entry L F C L F C F , L, T, S kit F kit (Connector side) C kit (Plug lead type) F , L, T, S kit F kit (Connector side) C kit (Plug lead type) (1) (1) Option Option VQC Nil W CD SD Standard IP65 enclosure For exhaust cleaner mounting Direct exhaust with silencer box Nil W CU SU Standard IP65 enclosure For exhaust cleaner
Refer to section "4.1 (1-1-2) View (V)" for how to display the Teaching window. c) How to command a Return to Origin operation. c-1) To perform a Return to Origin for each axis Select the button for the axis to be operated. c-2) To perform a Return to Origin for all axes Select the All axes Return to Origin button. d) The Return to Origin operation is completed when SETON is turned on.
Refer to section "4.1 (1-1-2) View (V)" for how to display the Teaching window. c) How to command a Return to Origin operation. c-1) To perform a Return to Origin for each axis Select the button for the axis to be operated. c-2) To perform a Return to Origin for all axes Select the All axes Return to Origin button. d) The Return to Origin operation is completed when SETON is turned on.
Rc C2SF-2J-A G Rc C2SF-2-A G NPT C2SFN-2J(Z)-A NPT C2SF-2(Z)-A -11- Option symbol C Note 1) C Note 1) Semi-standard symbol 6 C 6C Semi-standard: "C" Standard Port thread type Part No. Semi-standard: "-" Standard Port thread Part No. type Rc AD27-C-D G Rc AD27-D G NPT AD27-C(Z)-D NPT AD27(-Z)-D Appearance and part No. Semi-standard: "6C" Standard Port thread type Part No.
B A Dimensions [mm] Model Port size P A B C D E VXB215A D 3/8 23 55 99.8 88.3 11.5 VXB215B E 1/2 27 65 106.8 90.8 13.5 VXB215C F 3/4 32 75 111.5 93.2 16 6 Series VXB For Steam Replacement Parts How to order maintenance kit Maintenance Kit Insulated Adapter (for Individual Parts) VXB021-20-1A (1 set) VXB215 KT * Valve body is not included.
Rc C2SF-2J-A G Rc C2SF-2-A G NPT C2SFN-2J(Z)-A NPT C2SF-2(Z)-A -11- Option symbol C Note 1) C Note 1) Semi-standard symbol 6 C 6C Semi-standard: "C" Standard Port thread type Part No. Semi-standard: "-" Standard Port thread Part No. type Rc AD27-C-D G Rc AD27-D G NPT AD27-C(Z)-D NPT AD27(-Z)-D Appearance and part No. Semi-standard: "6C" Standard Port thread type Part No.
Round shaft Round shaft Round shaft Single flat D D D C D D D Round shaft Single flat Single flat (mm) Size 10 15 20 30 40 C D 8 14 9 18 10 20 13 22 15 30 Note) Dimensions and tolerance of the shaft and single flat (a parallel key for size 40) are the same as the standard.
RESET input Alarm group C There is no change. There is no change.
Indicator 45 22.5 27 1/8 Pilot port 5 17 D E OUT IN E C B 2 x P Port size A A Dimensions [mm] Model Port size P A B C D E VXB215A D 3/8 23 55 99.8 88.3 11.5 VXB215B E 1/2 27 65 106.8 90.8 13.5 VXB215C F 3/4 32 75 111.5 93.2 16 6 VXB Series For Steam Replacement Parts How to order the maintenance kit Maintenance Kit Insulated Adapter (for Individual Parts) VXB021-20-1A (1 set) VXB215 KT *
2-A 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 1-C 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 2-B CE2 6 1/8, 1/4 1.5 500 0 1,000 2,000 3,000 ML2B Max. speed Vmax (mm/s) 6 1/4, 3/8 3 1000 Graph 3:25 ML1C 10 1/4, 3/8 20 (1/4) 4.5 1500 20 10 1/4, 3/8 REA Composed effective area So (mm2) Composed effective area So (
AW-OMS0038-C PRODUCT NAME FILTER REGULATOR MODEL/ Series AW20-(F,N)01(F,N)02(B,C,E,G,H,M)(-1,2,6,C,J,N,R,Z)-B AW30-(F,N)02(F,N)03(B,C,D,E,G,H,M)(-1,2,6,8,J,N,R,W,Z)-B AW40-(F,N)02(F,N)04(B,C,D,E,G,H,M)(-1,2,6,8,J,N,R,W,Z)-B AW40-(F,N)06(B,C,D,E,G,H,M)(-1,2,6,8,J,N,R,W,Z)-B AW60-(F,N)06(F,N)10(B,C,D,E,G,M)(-1,2,6,8,J,N,R,W,Z)-B Contents PAGE 1. SAFETY INSTRUCTIONS 16 2. APPLICATION 7 3.
For installation and removal, use an appropriate pair of pliers (Tool for installing a type C snap ring). 2.
AF-OMQ0004-C PRODUCT NAME AIR FILTER MODEL / Series / Product Number AF10-M5(C)(-2,6,R,Z)-A AF20-(F,N)01(F,N)02(B,C)(-2,6,C,J,R,Z)-A AF30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,R,W,Z)-A AF40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,R,W,Z)-A AF40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-A AF50-(F,N)06(F,N)10(B)(-2,6,8,J,R,W,Z)-A AF60-(F,N)10(B)(-2,6,8,J,R,W,Z)-A Contents Page 1. SAFETY INSTRUCTIONS 1-5 2.
u t o s w i t c h A u t o s w i t c h s p e c i f i c a t i o n A u t o s w i t c h i n s t a l l a t i o n A u t o s w i t c h s e t p o s i t i o n I n t e r n a l s t r u c t u r e a n d o p e r a t i o n p r i n c i p l e C u s h i o n s M a i n t e n a n c e I n s p e c t i o n P e r i o d i c i n s p e c t i o n D i sassem ble and reassem bl e C a u t i o n o f d i
C (+) () Lead wire color Lead wire color B () Reset 100 VAC, 200 VAC 100 VAC, 200 VAC AC Yellow Yellow Set Blue Red A A Single solenoid (AC) Latching solenoid (AC) A Set A Blue Red COM Blue Red SOL. C C SOL. SOL. C COM SOL. Gray Gray Reset Single B C B Reset Latching Note 1) Single: No polarity ON: Orange light lights. Note 2) Setting side energizing: Orange light lights.
WETTED MATERIALS Polysulfone, Silicone, Buna-N TEMPERATURE RANGE 40 150 F (4 66 C) REPEATABILITY < +/1% F.S.