Valve Stations: 3 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations)
Valve Stations: 3 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations), CE Marked: None
Valve Stations: 3 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations)
Stations: 3 Stations, SUP/EXH Block Mounting: B (Both Sides 2~20 Stations)
Size: 4 (Size 425 Port Size 1/4,3/8,1/2 Flow 8000Nl/min), Pressure Setting: 2 (0.85MPa), Thread: Rc(PT), Port Size: 03 (3/8), Accessory: B (Bracket), Option: R (In-out Reversal)
Size: 30 (Size 3000, Flow 900Nl/min), Stations: 3 Stations, Piping Specification: B (IN: Individual), Thread: Rc(PT), Port Size: 03 (PT 3/8), Accessory: G1 (Pressure Gauge Back Face Thread)
Size: 30 (Size 3000, Flow 900Nl/min), Stations: 3 Stations, Piping Specification: B (IN: Individual), Thread: Rc(PT), Port Size: 03 (PT 3/8), Accessory: G2 (Pressure Gauge Vertical Face Thread)
Size: 30 (Size 3000, Flow 900Nl/min), Stations: 3 Stations, Piping Specification: B (IN: Individual), Thread: N (NPT), Port Size: 03 (PT 3/8), Accessory: G1 (Pressure Gauge Back Face Thread)
Size: 25 (Size 2500, Flow 750Nl/min), Stations: 3 Stations, Piping Specification: B (IN: Individual), Thread: N (NPT), Port Size: 02 (PT 1/4), Accessory: G2 (Pressure Gauge Vertical Face Thread)
Size: 25 (Size 2500, Flow 750Nl/min), Stations: 3 Stations, Piping Specification: B (IN: Individual), Thread: N (NPT), Port Size: 02 (PT 1/4)
Size: 30 (Size 3000, Flow 900Nl/min), Stations: 3 Stations, Piping Specification: B (IN: Individual), Thread: N (NPT), Port Size: 03 (PT 3/8)
Series: 544 (VP500), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: B (N.O., Normally Open)
Series: 744 (VP700), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC, 50/60Hz), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: B (N.O., Normally Open)
Series: 744 (VP700), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 2 (200VAC, 50/60Hz), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: D (Push-turn Locking Slotted Type), Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: B (N.O., Normally Open)
Series: 544 (VP500), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: B (N.O., Normally Open)
Series: 744 (VP700), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: B (N.O., Normally Open)
Series: 544 (VP500), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: B (N.O., Normally Open)
Series: 544 (VP500), Pilot Type: R (External Pilot), Pressure Specification: K (High-pressure Type, 1.0MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: B (N.O., Normally Open)
Series: 744 (VP700), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: B (N.O., Normally Open)
Series: 544 (VP500), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: L (L-type Plug Connector, 300mm Lead Wire Length), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 03 (3/8), Thread Type: Rc, Actuation Type: B (N.O., Normally Open)