Magnet: D (Built-in), Series: A2 (Standard), Mounting: L (Axial Foot), Tube Material: Aluminum, Bore Size: 63mm, Port Thread: Rc, Stroke: 350mm, Rod Boot: None, Cushion: N (Rubber Bumper), Pivot Bracket: None, Rod End Bracket: W (Double Knuckle Joint)

Magnet: D (Built-in), Series: A2 (Standard), Mounting: L (Axial Foot), Tube Material: Aluminum, Bore Size: 63mm, Port Thread: TN (NPT), Stroke: 500mm, Rod Boot: None, Cushion: Air Cushion, Pivot Bracket: None, Rod End Bracket: W (Double Knuckle Joint)

Magnet: D (Built-in), Series: A2 (Standard), Mounting: L (Axial Foot), Tube Material: Aluminum, Bore Size: 40mm, Port Thread: TN (NPT), Stroke: 700mm, Rod Boot: None, Cushion: Air Cushion, Pivot Bracket: None, Rod End Bracket: V (Single Knuckle Joint)

Magnet: D (Built-in), Series: A2 (Standard), Mounting: L (Axial Foot), Tube Material: Aluminum, Bore Size: 63mm, Port Thread: TN (NPT), Stroke: 400mm, Rod Boot: None, Cushion: Air Cushion, Pivot Bracket: None, Rod End Bracket: W (Double Knuckle Joint)

Pressure Range: L (0~100kPa), Port Size: 01 (Single Unit Mounting R(PT) 1/8), Output Specification: 19 (NPN Open Collector 1 Output, w/Analog Output, 200° Setting), Wiring Specification: L (Grommet Lead Wire 3m)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

Style: Pressure Switch w/ T-Spacer, Body Size: 20 (AC20), Thread Type: Rc, Port Size: 01 (1/8), Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: L (3m), Pressure Unit of the Scale Plate: MPa

Style: Pressure Switch w/ T-Spacer, Body Size: 30 (AC30), Thread Type: Rc, Port Size: 01 (1/8), Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: L (3m), Pressure Unit of the Scale Plate: MPa

Style: Pressure Switch with Piping Adapter, Body Size: 20 (AC20), Thread Type: Rc, Port Size: 01 (1/8), Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: L (3m), Pressure Unit of the Scale Plate: MPa, Mounting: Right

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: 01 (R1/8), Connector Type: S (M12 Connector Type)

Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m)

Series: 350 [3 Port COM (Single Unit)], Voltage: 6 (12VDC), Electrical Entry: G (Grommet / Tape winding), Orifice: 3 [350 (3 Port) ø3], Port Size: 01 [1/8 (6A)], Thread: Rc, Material: L (Stainless Steel Body, FKM Seal, Class B Coil)