This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FILTER REGULATOR, MODULAR, AIRLINE EQUIPMENT, AW MASS PRO, E6, AW MASS PRO 3/8 COPPER FREE, 1.10231 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, FILTER REGULATOR, MODULAR, AIRLINE EQUIPMENT, AW MASS PRO, EC, AW MASS PRO 3/8 MODULAR (NPT), 2.72331 lb
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. The modular design of the AR series connects with other SMC air preparation equipment.Modular type regulator, Optional embedded pressure gauge , Available with built-in backflow mechanism , Knob is
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units and
For applications requiring micro-mist separation up to 0.1 m with adjustable pressure regulation, the AWD offers these features built into one unit. This combination of products saves space and mounting hardware. Available with ports from 1/8 to 1/2 with NPT, Rc and G (PF) threads as standard. The many options available such as auto-drain, gauge, variety of bowl choices and regulation set
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MICRO MIST SEP REGULATOR, AIRLINE EQUIPMENT, AWD MASS PRO, EC, AWD MASS PRO 3/8 MODULAR NPT, 1.76000 lb
Combining a mist separator and regulator into one unit simplifies piping and installation. This combination controls the filtration to 0.3 m, for applications that require cleaner air than regular filtration, such as air blow off. As part of the family of modular air preparation units, the AWM can be combined with other similar sized products. This series is available with port sizes from
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation units and
Cost effective and clean looking, series AR regulators offer various pressure range settings to accommodate most applications. The locking adjustment knob prevents accidental setting changes. Options include a mounting bracket and set nuts for panel mounting, and a pressure gauge. The modular design of the AR series connects with other SMC air preparation equipment., REGULATOR MODULAR
Red ON Power source From US2 Installation Pin allocation of M12 4-pins (D-code) Socket for EX245-FPS3 The operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance.
4 JIS D1061 30G XYZ 3 IP65
D-P4DWL type is compatible with bore sizes 40 to 100. Only D-P4DW type is assembled when shipped. Lead wire length symbols: 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) J79CN Besides the models in the above catalog, there are some other auto switches that are applicable. For more information, refer to page 803.
Mini Free Mount Cylinder 4, 6, 8, 10 Series CUJ How to Order Bore size 4 6 8 10 4 mm 6 mm 8 mm 10 mm Made to Order Refer to pages 2 and 24 for details. 6 D 10 CUJ B D 10 F8N With auto switch CDUJ B 6 With auto switch (Built-in magnet) Number of auto switches 2 pcs. 1 pc. Nil S Mounting B Basic (Through-hole) M9: with 1 pc.
D-A9, M9, M9W, M9AL are shipped together, (but not assembled). (Switch mounting bracket is only assembled at the time of shipment.)
Refer to pages 17-6-3 to 17-6-10 for Safety Instructions and Solenoid Valve Precautions. 4 ' C ' C 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) ) D G C D, T S S L, Z 3 ) E E 3 0 ( 2 17-3-69 2 The VX series will be revised shortly. Series VXH Construction/Dimensions Material C3771 Note No.
N Body 2Yq 3-3/s s-Y4 6 1 A 1 y 2 9-2 B Brackel D Threaded draln poft (Female) except 220. Port slzo o2% o3-% 04-'/z 06 % to1 741'/z 20-2 Thread 1 Male 2fumale. ,NAMC220, 32O,520 only HowTo Select Flow Characteristics Supply prossure: 71 PSI Supply pressurei 71 tl 12 10.5 I 6 ! e E , q 1.5 8 1 2 1 6 2 0 Cylinder speed (in/sec.)
Accessory Dimensions 25.7 64 16 54 0.2 5 70 0.2 5 PWR (V) 40 BUS PWR 80 OUTPUT INPUT Cover view 2 x M4 Mounting hole OUTPUT INPUT COM D 60 COM C COM B COM A 1702
Thermo-chiller Series HRW Fluorinated Fluid Type SEMI How to Order 002 H HRW Fluorinated FluidType Option Cooling capacity Option Symbol Symbol 002 008 015 030 Cooling capacity None Nil C D N Z 2 kW Analog communication 8 kW DeviceNet communication 15 kW NPT fitting 30 kW Circulating fluid automatic recovery Pump inverter control Temperature range setting Pump inverter control None Applicable
D-A9V/M9V/M9WV/M9A(V) types cannot be mounted. Caution Since there are other applicable auto switches than listed, refer to page 406 for details. For details about auto switches with pre-wired connector, refer to pages 1784 and 1785. D-A9/M9/M9W auto switches are shipped together (not assembled). (Only switch mounting brackets are assembled at the time of shipment.)
A water-resistant type cylinder is recommended for use in an environment which requires water resistance. 21 m type lead wire is only applicable to D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.