System: Q (Vacuum Pump System for Manifold), Valves: J (Supply Valve; N.C., Release Valve; None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: L2 (L-type Plug Connector Lead Wire w/Connector), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
System: Q (Vacuum Pump System for Manifold), Valves: J (Supply Valve; N.C., Release Valve; None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: E (Digital Pressure Switch for Vacuum, -100 to 100, NPN 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: L3 (L-type Plug Connector), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
System: Q (Vacuum Pump System for Manifold), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: L2 (L-type Plug Connector Lead Wire w/Connector), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: L2 (L-type Plug Connector Lead Wire w/Connector), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
System: Q (Vacuum Pump System for Manifold), Valves: J (Supply Valve; N.C., Release Valve; None), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
System: Q (Vacuum Pump System for Manifold), Valves: R (Supply Valve; Self-holding, Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting)
Size: 200 (1/8 Standard), Control Range: FSM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Tube Size: 07 (ø1/4)
Size: 100 (M5 Standard), Control Range: FSM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Tube Size: 07 (ø1/4)
Size: 205 (1/4 Standard), Control Range: FSM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Tube Size: 07 (ø1/4)