[N] Bore size [mm] 6 8 12 16 20 25 Piping port size M5 x 0.8 Fluid Air Action Double acting Operating pressure 0.15 to 0.7 MPa*1 (End lock: 0.35 to 0.7 MPa)*1 Bore size [mm] Rod size [mm] Operating direction Piston area [mm2] Operating pressure [MPa] 0.2 0.3 0.4 0.5 0.6 0.7 6 3 OUT 57 11 17 23 29 34 40 IN 42 8 13 17 21 25 29 Proof pressure 1.05 MPa 8 4 OUT 101 20 30 40 51 61 71 Ambient and

Pressure Sensor Series PSE530 How to Order PSE53 0 M5 Sensor range Option None 0 1 2 3 Positive pressure [0 to 1 MPa] Vacuum [0 to 101 kPa] Low pressure [0 to 101 kPa] Compound pressure [101 to 101 kPa] Nil Port size Sensor cable (3 m) M5 R06 R07 M5 x 0.8 6 reducer 1/4 inch reducer L ZSE ISE Option ZSP Connector for pressure sensor controller (1 pc.) + Sensor cable (3 m) Description Part

25 32 40 M8 x 1.25 5 28 41 8 57.5 18 13 M20 x 1.5 13 26 5 8 15 24 20 0 0.033 26 0 0.033 26 0 0.033 32 0 0.039 15.5 M10 x 1.25 5.5 33.5 45 10 63.5 22 13 M26 x 1.5 17 32 6 8 15 30 19.5 M10 x 1.25 5.5 37.5 45 12 68 22 13 M26 x 1.5 17 32 6 8 15 34.5 19.5 M14 x 1.5 7 46.5 50 14 76 24 16 M32 x 2 22 41 8 10 21.5 42.5 21 Dimensions by Stroke Single Acting/Spring Extend Stroke 1 to 50 51 to 100 101

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 20 1 10 30 31 100 101 200 300 1 10 30 31 100 101 200 300 Stroke (mm) Stroke (mm) MLGPL32 to 63 MLGPL32 to 63 30 30 50, 63 50, 63 Load weight m (kg) 50, 63 50, 63 50, 63 32, 40 32, 40 10 10 32, 40 32, 40 50, 63 32, 40 32, 40 5 10 50 51 100 101 5 10 50

PSE3 Applicable pressure sensor For compound For vacuum For low pressure For positive For low differential Rated pressure range -100 to 100 kPa 0 to -101 kPa 0 to 100 kPa 0 to 1 MPa 0 to 500 kPa 0 to 2 kPa Set pressure range 1 -101 to 101 kPa 10 to -101 kPa -10 to 100 kPa -0.1 to 1 MPa -50 to 500 kPa -0.2 to 2 kPa Set pressure resolution 0.2 kPa 0.1 kPa 0.1 kPa 0.001 MPa 1 kPa 0.01 kPa

(Refer to page 403 for details of the MK2T series.) 12, 16 20, 25 103 101 MK 102 (MK2T) Allowable moment of inertia [kgm2] Allowable moment of inertia [kgm2] 104 MK 103 105 16 Standard arm single unit 104 20, 25 Standard arm single unit 12 Standard arm single unit 106 105 50 100 200 50 100 200 Maximum piston speed [mm/s] Maximum piston speed [mm/s] 32, 40 50, 63 101 101 (MK2T) MK (MK2T) Allowable

Front matter 1 Model Selection Moment of Intertia 12, 16 20, 25 103 101 102 MK MK2T Allowable moment of intertia [kgm2] Allowable moment of intertia [kgm2] 104 MK2 103 MK 105 16 Standard arm single unit 104 20, 25 Standard arm single unit 12 Standard arm single unit 106 105 50 100 200 50 100 200 Maximum piston speed [mm/s] Maximum piston speed [mm/s] 32, 40 50, 63 101 101 MK2T MK2T MK2 Allowable

to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 600 601 to 700 701 to 800 801 to 900 901 to 1000 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 600 601 to 700 701 to 800 801 to 900 134 CP96 Series Dimensions Basic: CP96S (D) B C (JJ) W Bore size Stroke With rod boot at both ends PL 2 x EE port PL Cushion valve Width across flats SW Width across

Rated pressure range Rated pressure range Rated pressure range Rated pressure range Rated pressure range 100 kPa to 100 kPa 0 to 500 kPa 0 to 1 MPa 0 to 2 MPa 0 to 5 MPa 0 to 10 MPa 101 kPa to 0 100 kPa to 100 kPa 0 to 100 kPa 0 to 1 MPa 101 kPa to 0 100 kPa to 100 kPa 0 to 1 MPa 0 to 2 kPa 101 kPa to 0 100 kPa to 100 kPa 0 to 500 kPa 0 to 1 MPa C O N T E N T S How to Order p. 7 Internal

to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 600 601 to 700 701 to 800 801 to 900 901 to 1000 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 600 601 to 700 701 to 800 801 to 900 167 A ISO Standard (15552) Air Cylinder: Standard Type Double Acting, Single/Double Rod C96 Series Dimensions: With Mounting Bracket (Dimensions are common to single

111 115 138 144 194 214 222 267 279 101 111 115 138 144 202 222 230 276 288 Up to 500 Up to 600 Up to 600 Up to 750 Up to 750 1/4 Stroke 1/4 Stroke 1/4 Stroke 1/4 Stroke 1/4 Stroke 103 107 129 135 110 140 162 110 130 100 Do not disassemble the trunnion type.

bumper 2 g Option mass: Double clevis style 92 g Mass/Without Auto Switch (g) Cylinder stroke (mm) Bore size (mm) 250 300 200 175 150 125 25 100 15 20 30 35 40 50 75 10 5 45 12 312 279 246 213 56 180 42 49 63 93 100 113 147 36 29 107 16 397 355 313 271 73 229 56 64 82 128 145 187 47 119 38 136 201 g 20 627 562 498 434 101 114 127 370 88 153 178 306 75 140 63 166 25 794 952 715 636 557

to 150 50 50 50 50 50 50 201 to 300 100 100 100 100 100 100 301 to 400 125 125 125 125 125 125 401 to 500 150 150 150 150 501 to 600 175 175 601 to 700 187.5 187.5 701 to 750 73 81 89 89 101 101 1 to 50 86 94 102 102 114 114 51 to 100 98 106 114 114 126 126 101 to 150 111 119 127 127 139 139 201 to 300 161 169 177 177 189 189 301 to 400 186 194 202 202 214 214 401 to 500 227 227 239

Valve size 16 25 40 50 63 80 Bellows assembly u XL1A16-2-101 XL1A25-2-101 XL1A40-2-101 XL1A50-2-101 XL1A63-2-101 XL1A80-2-101 Nut assembly o XL1A16-10-1 XL1A25-10-1 XL1A40-10-1 XL1A50-10-1 XL1A80-10-1 Bellows assembly * Bellows assembly includes the valve seal 1 (Standard material: FKM).

Switching function of [F 0] Pressure range, display unit and switch output specifications Page 30 Item Default setting Connected sensor range -101 kPa Display units kPa Switch output specifications NPN/PNP : Depends on part number.

Refer to the outline dimension drawing (page 101) for mounting hole dimensions. The self tapping screws should not be re-used. Direct mounting (PF3W711/721) Mount using the self tapping screws (nominal size: 4.0 x 4 pcs.) for installation. The tightening torque must be 1.0 to 1.2 Nm. Refer to the outline dimension drawing (page 101) for mounting hole dimensions.

JIS symbol Theoretical Force Unit: N OUT IN Operating pressure (MPa) Rod diameter (mm) Piston area (mm 2) Bore size (mm) Operation 0.3 0.5 0.7 84.8 IN 25 42 59 12 6 CU 113 OUT 34 57 79 151 IN 45 75 106 16 CQS 8 201 OUT 60 101 141 236 IN 71 118 165 CQ2 20 10 314 OUT 94 157 220 MU 378 IN 113 189 264 25 12 491 OUT 147 245 344 Intermediate Strokes Spacer is attached on standard stroke body.

screw 12 10 20 12 10 20 20 20 40 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 2 Horizontal 8 25 25 18 Standard motor 8 12 8 12 24 5 10 5 10 Vertical 32 10 12 10 20 10 12 10 20 40 High rigidity direct acting guide LJ1H 20 20 40 44 Horizontal 50 25 25 60 Non-standard motor 8 12 8 12 66 5 10 5 10 Vertical 74 10 10 82 Options Page 100 Made to Order 101

P Rated pressure range: 0.0 to 101.0 kPa 0 101 kPa Expanded pressure range for positive-pressure type to the vacuum range.