PF2W504--1 PF2W520--1 PF2W540--1 PF2W511--1 PF2W504--2 PF2W520--2 PF2W540--2 PF2W511--2 4 0.5 4 0.5 16 2 16 2 40 5 40 5 100 10 100 10 19 Series PF2W For Water Digital Flow Switch to are terminal numbers.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4 16 100 40 03 04 06 10 3/8 1/2 3/4 1 PF2W504, PF2W520 PF2W520, PF2W540 PF2W540, PF2W511 PF2W511 Specifications PF2W504 PF2W520 PF2W540 PF2W511 Model Measured fluid Water Detection type Karman vortex 0.5 to 4 l/min 2 to 16 l/min 5 to 40 l/min 10 to
Roller Lever/VM121-01-01, VM131-01-01 VM121-01-01S, VM131-01-01S JIS Symbol 2 port 3 port 10N F.O.F. 0.5MPa supply 3.2mm P.T. 2.3mm O.T. 5.5mm T.T. One Way Roller Lever/VM121-01-02, VM131-01-02 VM121-01-02S, VM131-01-02S JIS Symbol 2 port 3 port 10N F.O.F. 0.5MPa supply 3.2mm P.T. 2.3mm O.T. 5.5mm T.T.
Default settings Item Default Setting Page [n_1] Input of the Set point 1 (OUT1) 50% of max. rated flow PF2A30: [ 5.0] L/min (PF2A510) PF2A31: [ 50] L/min (PF2A511) [F_1] [n_2] Input of the Set point 2 (OUT1) Input the Set value of Page 27 PF2W30: [2.00] L/min (PF2W504) [n_3] Input of the Set point 3 (OUT2) instantaneous output PF2W33: [ 50] L/min (PF2W511) PF2D30: [2.00] L/min (PF2D504
KFV-04 KFV-06 KFN-04 KFN-06 KFW-04 KFW-06 KFS-04 KFS-06 4/2.5 6/4 KFV-08U 8/5 KFV-08N 8/6 KFV-10U 10/6.5 KFV-10N 10/7.5 KFV-12U 12/8 KFV-12N 12/9 4 6 KFN-08 8 KFN-10 10 KFN-12 12 4/2.5 6/4 KFW-08U 8/5 KFW-08N 8/6 KFW-10U 10/6.5 KFW-10N 10/7.5 KFW-12U 12/8 KFW-12N 12/9 4 6 KFS-08 8 KFS-10 10 KFS-12 12 Precautions Be sure to read before handling.
KFN-04 KFN-06 KFW-04 KFW-06 KFV-04 KFV-06 KFS-04 KFS-06 4 6 KFN-08 8 KFN-10 10 KFN-12 12 4/2.5 6/4 KFW-08U 8/5 KFW-08N 8/6 KFW-10U 10/6.5 KFW-10N 10/7.5 KFW-12U 12/8 KFW-12N 12/9 4/2.5 6/4 KFV-08U 8/5 KFV-08N 8/6 KFV-10U 10/6.5 KFV-10N 10/7.5 KFV-12U 12/8 KFV-12N 12/9 4 6 KFS-08 8 KFS-10 10 KFS-12 12 Precautions Be sure to read before handling.
UP/DOWN On OFF SET )On/OFF MODE , SEL. , SET RIGHT LEFT UP DOWN RIGHTLEFTUPDOWN 10N 19 - 7-3 7-3-1 -7,999,999+7,999,999, F, (+8,000,000 ,F,-8,000,000 ,-F ,,F) 6 (-999,999+999,999),6 7-3-2 , 0 , ,RS-232C BCD ,,, 7-3-3 ,14 No. 2 1 1 OFF OFF 2 OFF ON 3 ON OFF 4 ON ON 7-3-4 No.
PF2W520 PF3W520 PF2W540 PF3W540 PF2W511 PF3W511 PF2W504 PF3W504 Function selection mode Safety Instructions Other functions Sensor connector Mounting and Installation PF2D2 series Lever Warning Installation or Channel scan function Peak / Bottom value display Key-lock function PF2D520 PF2D540 PF2D504 Do not disassemble, modify (including changing the printed circuit board) or repair.
Allowable external resistance Nominal size Allowable external resistance 16 10N 25 20N When the floating bracket is used Installation of a holding bolt. Install the pin and the conical spring washer in the slider with a holding bolt.
PF2A20 series 1 to 5 to 10 L/min type (PF2A510) 50 L/min type (PF2A550) [10L]: [50L]: [11L]: [21L]: [51L]: 10 to 20 to 50 to 100 L/min type (PF2A511) 200 L/min type (PF2A521) 500 L/min type (PF2A551) PF2W20 series 0.5 to 4 L/min type (PF2W504) (PF3W504) [04L]: [20L]: [40L]: [11L]: 2 to 5 to 16 L/min type (PF2W520) (PF3W520) 40 L/min type (PF2W540) (PF3W540) 10 to 100 L/min type (PF2W511)
Stroke (mm) Pulling force Bore size (mm) 40, 50, 63 80, 100 Thread size 3 10N M3 x 0.5 x 30l or more 3 24.5N M5 x 0.8 x 40lor more Remove the bolt for normal operation. It can cause lock malfunction or faulty release. Rubber cap wManual release lock type Push the M/O knob and turn it 90 counterclockwise.
Bore size (mm) 32 40, 50, 63 80, 100 Thread size M2.5 X 0.45 X 25 l M3 X 0.5 X 30 l M5 X 0.8 X 40 l Pulling force 4.9N 10N 24.5N Stroke (mm) 2 3 3 e Release lock when mounting or adjusting the cylinder. If mounting is done with lock engaged, lock mechanism may be damaged. * Remove bolt under normal operations.
Mass (Handle / Bonnet material) B (Aluminum) 92g 156g 301g 349g 630g (2) Double action type Model VHS2510 VHS3510 VHS4510 VHS4510-06 VHS5510 Fluid Air Ambient and fluid temperature -5 to 60oC (No freezing) Proof pressure 1.5MPa Operating pressure range 0.1 to 1.0MPa Color (Standard) Handle: Red Body: White Handle operation Pushing stroke 3.2mm 4.2mm Switching angle 90o Push force Note1) 10N
19.6 m/s2 Nominal size:16 5kg 1.25kg 10kg 2.5kg Maximum load weight NOTE2) Nominal size:25 20kg 5kg 10kg 2.5kg Acceleration and deceleration method Trapezoidal drive Moving direction Horizontal direction Positioning points Both ends (mechanical stoppers), 1 intermediate position Both ends 0.01mm Repeated Positioning stopping precision Intermediate stopping position 0.1mm Nominal size:16 10N
Sensor unit PF2A510 PF2A550 PF2A511 PF2A521 PF2A551 PF2A710 PF2A750 PF2A711 PF2A721 PF2A751 PF2A703H PF2A706H PF2A712H 1 to 10 5 to 50 10 to 100 20 to 200 50 to 500 150 to 3000 300 to 6000 600 to 12000 PF2A30 PF2A20 PF2A31 For Water For Water P. 15 Remote type Flow rate measurement range l/min Integrated type Display unit Display unit (4ch) Sensor unit PF2W504(T) PF2W520(T) PF2W540(T) PF2W511
For setting the holding force to be at least 20 times the work weight; Required holding force = 0.05kg X 20 X 9.8m/s2 = 10N min. 0 20 30 40 50 60 70 Holding point L (mm) When MHY2-16D is selected, the holding force is determined to be 13N according to the holding point distance (L = 35mm) and the pressure (0.6MPa).
Unit Remark Reference unit/s (default) 10n [reference unit/s] can be set. Reference unit/min 10n [reference unit/min] can be set. "%" of rated speed 10n [%] can be set. min1 (rpm) 10n [min1] can be set. Max. motor speed/40 (Hex.) Set "0" for common parameter 42. (2) Position The following units can be selected. Settings are made with common parameters 43 and 44.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4 16 100 40 03 04 06 10 3/8 1/2 3/4 1 PF2W504, PF2W520 PF2W520, PF2W540 PF2W540, PF2W511 PF2W511 Specifications PF2W504 PF2W520 PF2W540 PF2W511 Model Measured fluid Water Detection type Karman vortex 0.5 to 4 l/min 2 to 16 l/min 5 to 40 l/min 10 to
CL MLG Stroke (mm) Pulling force Bore size (mm) 20, 25, 32 40, 50, 63 80, 100 Thread size CNA 2 4.9N M2.5 X 25l 3 10N M3 X 3l CNG 3 24.5N M5 X 40l Bolt should be detached under normal operation, otherwise it may cause malfunction of the locking feature. MNB wThe lock piston is pushed further upward.
Use a finger only with a force of less than 10N. 7-3. Counter operation 7-3-1. Handling data range Data range of the counter inside is between-7,999,999 to + 7,999,999. If a value in the counter is out of the range, it displays F and stops counting (For over + 8,000,000, it displays F and displaysF for below-8,000,000. -F is displayed with the decimal point already set).