B L2 Q L1 H 1(P) 2(A) L3 L4 L5 L6 C D E F G J K 1(P) R 2(A) 2(A) R 3(R)* VHK-01S-M5 VHK-M5-M5 11 41 1.2 26 23 11 3.5 11 M5 M5 M5 18 29.1 16.5 VHK-B1A 29 29.1 44.5 14.5 1 27 22 16.5 26 61.6 58.2 2.0 2.0 54 51 1 8 11 41 8.6 1.2 13 3.5 18 32.6 16.5 13 VHK-B1A 44.5 14.5 1 27 22 16.5 26 VHK-01S-01S 1 8 1 8 30 32.6 65.2 57 VHK-02S-01S 18 41 71.6 39 32.6 39 78 16.5 3.5 11 9.0 9.7 1.2 39 13 47 62
B L2 Q L1 H 1(P) 2(A) L3 L4 L5 L6 C D E F G J K 1(P) R 2(A) 2(A) R 3(R)* VHK-01S-M5 VHK-M5-M5 11 41 1.2 26 23 11 3.5 11 M5 M5 M5 18 29.1 16.5 VHK-B1A 29 29.1 44.5 14.5 1 27 22 16.5 26 61.6 58.2 2.0 2.0 54 51 1 8 11 41 8.6 1.2 13 3.5 18 32.6 16.5 13 VHK-B1A 44.5 14.5 1 27 22 16.5 26 VHK-01S-01S 1 8 1 8 30 32.6 65.2 57 VHK-02S-01S 18 41 71.6 39 32.6 39 78 16.5 3.5 11 9.0 9.7 1.2 39 13 47 62
Specification for Option R 11 1 Safety instructions .11 1 11 2 Specifications .11 1 11 3 Power supply connection procedure .11 2 11 4 Cautions for handling the GFCI .11 3 11 5 Electric circuit .11 3 Chapter 12 Specification for Option S 12 1 Safety instructions . 12 1 12 2 Specifications . 12 1 12 3 Electric circuit . 12 1 Chapter 13 Specification for Option T 13 1 Safety instructions .
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge
Specification for Option R 11 1 Safety instructions . 11 1 11 2 Specifications . 11 1 11 3 Power supply connection procedure . 11 2 11 4 Cautions for handling the GFCI . 11 3 11 5 Electric circuit . 11 3 Chapter 12 Specification for Option S 12 1 Safety instructions . 12 1 12 2 Specifications . 12 1 12 3 Electric circuit . 12 1 Chapter 13 Specification for Option T 13 1 Safety instructions
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge temp. 4 High circulating fluid return temp. 5 High circulating
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge temp. drop 4 High circulating fluid return temp. 5 High circulating
Specification for Option M 11 1 Safety instructions . 11 1 11 2 Specifications . 11 2 11 3 Installation of motor type auto drain . 11 3 11 4 Electric circuit . 11 3 Chapter 12 Specification for Option R 12 1 Safety instructions . 12 1 12 2 Specifications . 12 1 12 3 Power supply connection procedure . 12 2 12 4 Cautions for handling the GFCI . 12 3 12 5 Electric circuit . 12 3 Chapter 13
Adjustment method 6 3.1 Vertical auto switch unit 6 Operating Range and Hysteresis 6 Auto Switch Mounting 7 Auto Switch Adjustment 10 3.2 Angle adjustment unit 11 Rotating angle with angle adjustment unit 11 Rotating Angle Adjustment Method 11 4.
/ mm mm mm c.p.m. mm(L1-L2) (L1) (L2) g MHL2-10D 60 20 56 76 280 MHL2-10D1 40 78 118 345 10 40 MHL2-10D2 60 96 156 425 MHL2-16D 60 30 68 98 585 MHL2-16D1 60 110 170 795 16 40 MHL2-16D2 80 130 210 935 MHL2-20D 60 40 82 122 1,025 MHL2-20D1 80 142 222 1,495 20 40 MHL2-20D2 100 162 262 1,690 MHL2-25D 60 50 100 150 1,690 MHL2-25D1 100 182 282 2,560 25 40 MHL2-25D2 120 200 320 2,775 MHL2-32D
Lock unit model Bolt Hexagon wrench size Tightening torque (Nm) MWB32 MWB40 MB-32-48-C1247 4 5.1 MWB50 MWB63 MB-32-48-C1249 5 11 Foot MB-80-48AC1251 MWB*80 6 25 MWB*100 Other MB-80-48BC1251 There is a vent hole on the element. If the ventilation is not adequate, there will be locking/ unlocking delay or operation failure. Install the cylinder so that the element is not covered.
200 300 400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Pressure Characteristics Conditions: Upstream pressure 0.7MPa Downstream pressure 0.2MPa Flow rate Q = 20l/min (ANR) 0.30 Downstream pressure MPa 0.25 Starting point 0.20 0.15 0.10 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Upstream pressure MPa Construction ARJ310
Using cylinders are beyond the limit may shorten the product service life or cause damage. 5st 10st 15st 20st 250 Load mass W (g) Operating pressure 0.3 MPa Operating pressure 0.5 MPa or more 200 10 150 L L 100 MGJ10 W W 1 Load mass (kg) 50 0 0 5 10 15 20 MGJ6 0.1 Eccentric distance L (mm) 0.01 0.1 1 10 100 Eccentric distance L (mm) Construction Parts list o!0!6 w i !4 !3 y u r !1 q t !
, 21-/22-: Lithium soap based grease 10-/21-: Class 4, 11-/22-: Class 3 685
Basic/Double-side bossed/Single foot/Double foot/Rod side flange/Head side 10-/11-: Fluorine grease, 21-/22-: Lithium soap based grease 10-/21-: Grade 2, 11-/22-: Grade 1 2 B
For clean type (11-) or secondary battery (25A-) type actuator Search without entering 11or 25A-, and select the actuator for which the part number after 11or 25Amatches. e.g.) For 11-LEFSH16A-100BR, enter "LEFS16A-100" and select LEFS16A-100.
Duplicate MAC ID Check Message Unconnected Explicit Message Explicit Message Applicable message MAC ID set range 0 to 63 Data rate 125 kbps 250 kbps 500 kbps Thick cable 500 m or less 250 m or less 100 m or less Max. length of the network Thin cable 100 m or less 156 m or less 78 m or less 39 m or less Total main and branch line length : Max. length of branch line is 6 m.