Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Y (DC Low Wattage Type (0.5W), Power Supply Voltage: 5 (24VDC), Electrical Entry: LO (L Plug Connector w/o Connector, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P3 (Pressure Sensor, -100 to 100kPa, Accuracy
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: B (Locking Type), Suction Filter: F (Suction Filter), Pressure Sensor Specs: P3 (Pressure Sensor, -100 to 100kPa, Accuracy ±2% F.S.
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: N1 (Supply: Latching Negative Common, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: B (Locking Type), Suction Filter: F (Suction Filter), Pressure Sensor Specs: P3 (Pressure Sensor, -100 to 100kPa
Power supply is 1-Phase 200 VAC Trouble OFF ON RA MC Emergency stop MC SK (Note 6) Driver Servo motor Servo amplifier (Note 7) MCCB CNP1 MC NFB 1-phase 200 to 230VAC L1 CNP3 (Note 5) U L2 U Motor V L3 V [1] M W N W P3 P1 (Note 1) P2 P4 PE CNP2 P [2] [3] (Note 2) C D Encoder CN2 (Note 3) Encoder cable L11 L21 [1] Power supply input terminal: Supply specified power supply. [2] Connect the motor
Power supply is AC200V single phase (Note 4) Malfunction RA1 OFF ON MC MC SK EMG stop switch Driver Servo amplifier Servo motor MC (Note 7) MCCB CNP1 1-phase 200 V AC to 240 V AC (Note 11) L1 CNP3 (Note 6) U U L2 Motor V V L3 M [1] W NW P3 (Note 1) (Note 10) P4 CNP2 P+ [2] (Note 2) C [3] D (Note 11) (Note 3) Encoder CN2 Encoder L11 cable L21 (Note 8) Main circuit power supply CN3 EM2 24 V
P3 Synchronous communications enabled. Both synchronous and asynchronous commands can be used. 3 8-4 8 MECHATROLINK-II Commands 8.1.4 Terminology (1) Transmission Cycle and Communications Cycle Transmission Cycle: The transmission cycle is the cycle in the MAC (Media Access Control) layer. It is the communications cycle for physically sending data to the transmission path.
Q2 +COM 30.30.4 4 L L 5 DC24V LO L 6 DC12V M M 5 MO M 5 4300 5MMO 6 B 6() 9 - No.ZB-OM00301 / kPa / P1 0-101 15V2F.S.7 P3 -100100 15V2F.S.7 8 EA EAM SI 9 NPN2 EAP [psi] 8 0-101 8 EB EBM SI 9 PNP2 EBP [psi] 8 8 FA FAM SI 9 NPN2 FAP [psi] 8 -100100 8 FB FBM SI 9 PNP2 FBP [psi] 8 73m 8 9kPa G 2m V 10 11 12 C2 2 B C4 4 N1 1/8 N3 5/32 K 12 L2 2 L4 4
Domensions Plate thickness AR20M/30-MD: Max.3.5 AR40-D: Max.5 Dimensions Optional specifications Round type pressure gauge (Semi-standard:Z) Round type pressure gauge (with color zone) Standard specifications Round type pressure gauge Model P1 P2 P3 A BNote 1) C D F J K L1 H J H J H J AR20M-D 1/81/4 1/8 1/81/4 40 66.8 26.5 21 M28X1 26 2 9 37.5 62.5 37.5 63.5 37.5 63.5 AR30M-D 1/43/8 1/8 1
O PERATI O N M AN U AL E/P REGULATOR M O D EL N AM E ITV1000, ITV2000, ITV3000 series Seri es
Air leakage Air leakage to naighoring port more than allowable lekage(P3). 1) Galling of sliding part Replace the rotary joint. Refer Rotation failure above. Increased rotation resistance. This leads to wear out fixed O ring due to sleeve rotating. 2) Galling of sliding Replace the rotary joint. Refer Rotation failure above. part increased rotation resistance.
Step Step Step Step Step Step Preset output pressure 20 1 2 3 5 P4 P3 P2 P1 Analog signal Analog signal Controller Time Actuator Electropneumatic Actuator Electropneumatic pressure regulator pressure regulator PWR ERR 0-10VDC Series ITV 4-20mA Series IC Series IC Series IC Coming out in Coming out in July, July, 4 point pressure switch function 4 point pressure switch function 4 point pressure
SG Connector location P3: Not used for the maintenance purpose port D-sub 9 (Male receptacle) P2: Serial RS-485 D-sub 9 (Female receptacle) P1: Contact input/output D-sub 25 (Female receptacle) Power cable entry Rear side 116 Common Specifications Series HRW Operation Display Panel q Description No.
s [3 cP] or less) Note 1)Karman vortex10 to 100 L/min0 to 70oC (with no freezing and condensation)p3% F.S.p2% F.S.p5% F.S. (25oC reference)0 to 1 MPa Note 2)1 MPa45 kPa or less at the maximum flow1 sVoltage output: 1 to 5 V Output impedance: 1 k7Output current: 4 to 20 mA Max. load impedance: 300 7 for 12 VDC, 600 7 for 24 VDCFor power supply status, flow rate indicator (Blinking speed
.; Release Valve: N.C., Rated Voltage: 24VDC, Electrical Entry: L-Type Plug Connector w/Lead Wire, Manual Override: Non-Locking Push Type, Sensor/Switch Specifications: P3 [Pressure Sensor: -14.5 to 14.5 (-100 to 100); Output: 1 to 5V, Accuracy ±2% F.S. or Less], Pressure Switch Lead Wire: w/o Lead Wire w/Connector, Vacuum Port: Elbow ø1/8" One-Touch Fitting, Option: -
.; Release Valve: N.C., Rated Voltage: 24VDC, Electrical Entry: L-Type Plug Connector w/Lead Wire, Manual Override: Non-Locking Push Type, Sensor/Switch Specifications: P3 [Pressure Sensor: -14.5 to 14.5 (-100 to 100); Output: 1 to 5V, Accuracy ±2% F.S. or Less], Pressure Switch Lead Wire: w/o Lead Wire w/Connector, Vacuum Port: Straight ø5/32" One-Touch Fitting, Option: Screwdriver Handling
.; Release Valve: N.C., Rated Voltage: 24VDC, Electrical Entry: L-Type Plug Connector w/Lead Wire, Manual Override: Non-Locking Push Type, Sensor/Switch Specifications: P3 [Pressure Sensor: -14.5 to 14.5 (-100 to 100); Output: 1 to 5V, Accuracy ±2% F.S. or Less], Pressure Switch Lead Wire: w/o Lead Wire w/Connector, Vacuum Port: Straight ø4mm One-Touch Fitting, Option: Bracket for Single
.; Release Valve: N.C., Rated Voltage: 24VDC, Electrical Entry: L-Type Plug Connector w/Lead Wire, Manual Override: Non-Locking Push Type, Sensor/Switch Specifications: P3 [Pressure Sensor: -14.5 to 14.5 (-100 to 100); Output: 1 to 5V, Accuracy ±2% F.S. or Less], Pressure Switch Lead Wire: w/o Lead Wire w/Connector, Vacuum Port: Elbow ø1/8" One-Touch Fitting, Option: -
.; Release Valve: N.C., Rated Voltage: 24VDC, Electrical Entry: L-Type Plug Connector w/Lead Wire, Manual Override: Locking Type, Tool Required, Semi-Standard, Sensor/Switch Specifications: P3 [Pressure Sensor: -14.5 to 14.5 (-100 to 100); Output: 1 to 5V, Accuracy ±2% F.S. or Less], Pressure Switch Lead Wire: w/o Lead Wire w/Connector, Vacuum Port: Straight ø5/32" One-Touch Fitting, Option
.; Release Valve: N.C., Rated Voltage: 24VDC, Electrical Entry: L-Type Plug Connector w/Lead Wire, Manual Override: Non-Locking Push Type, Sensor/Switch Specifications: P3 [Pressure Sensor: -14.5 to 14.5 (-100 to 100); Output: 1 to 5V, Accuracy ±2% F.S. or Less], Pressure Switch Lead Wire: w/o Lead Wire w/Connector, Vacuum Port: Straight ø4mm One-Touch Fitting, Option: B+K
.; Release Valve: N.C., Rated Voltage: 24VDC, Electrical Entry: L-Type Plug Connector w/Lead Wire, Manual Override: Non-Locking Push Type, Sensor/Switch Specifications: P3 [Pressure Sensor: -14.5 to 14.5 (-100 to 100); Output: 1 to 5V, Accuracy ±2% F.S. or Less], Pressure Switch Lead Wire: w/o Lead Wire w/Connector, Vacuum Port: Straight ø1/8" One-Touch Fitting, Option: -