IRV 2 VEX 1(P) 3(R) 2(A) Simplified main circuit n SRH SRP 1 SRF 3(R) 2 ITV Simplified pilot circuit 1(P) 2(A) P2 P1 3(R) 1(P) IC 1(P) 2(A) n E-P HYREG Ease of handling ITVH Having the amplifier built into the electro-pneumatic pilot valve, only an external power supply and signal (voltage, current) need to be connected.

P2 = 1.5 x 0.5-0.024 x 15 = 0.39 MPa Retraction r RHC The above values are for cases where the maximum payload found by the selection method is loaded. 0.2 MK(2) 0.1 100 200 300 Speed adjustment RS Q G Max. speed (mm/s) The data below illustrates the strokes controlled by the respective speed controllers. Gradually increase from a low speed to the desired speed setting.

Replacement parts PAB-OM-C006-B P2 FLUID IN FLUID OUT P1 IN FLUID PT F E diaphragm set K T PA 3 3 1 S w itching valve assembly set K T PA 3 3 6 FLUID OUT P2 P1 4 . Maintenance 3 . How to use C aution Quality of supply air Place filter w ith filtration 5 m.

Replacement parts PAB-OM-C007-B P2 FLUID FLUID OUT IN P1 PT F E diaphragm set K T PA 5 3 1 S w itching valve assembly set K T PA 5 3 6 FLUID IN FLUID OUT P2 P1 4 . Maintenance 3 . How to use E xternal leakage of transported fluid F luid might leak externally due to life of diaphragm, and this could result in human injury or equipment damage. T ake measures against leakage.

Operate within the ranges of the maximum operat ing pressure and back pressure. -5- How to Order LVP 5 0 16A P2 W Valve type 0 1 2 Rubber material N.C. N.O. Type Symbol FKM EPDM Material Symbol Standard Low water hammer type Type Nil N Double acting Nil W Pilot port position (Refer to the figure above.)

Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow rate calculated with the about formula by a coefficient from the table below.

Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow rate calculated with the about formula by a coefficient from the table below.

Standard (with round type pressure gauge) (Pressure gauge port size) (Port size) Panel mounting dimensions Plate thickness AR20/30-D: Max.3.5 AR40-D: Max.5 Dimensions Optional specifications Standard specifications Round type pressure gauge (Semi-standard: Z) Round type pressure gauge (with color zone) Round type pressure gauge Model M281 P1 P2 J K J H J J AR20-D 1/8 40 66.8 26.5 21 21

How to Find the Flow Rate (at air temperature of 20 ) Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) S: Effective sectional area (mm 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow

Subsonic flow when (P2+0.100)/ (P1+0.100)>0.5 Q=240S P(P1+0.100) Sonic flow when (P2+0.100)/ (P1+0.100)0.5 Q=120S (P1+0.100) Q: Air flow ratedm 3 /min(ANR) 2 ) P: Differential pressure P1P2MPa P1: Upstream pressureMPa P2: Downstream pressureMPa Correction for different air temperatures Multiply the flow rate calculated with the about formula by a coefficient from the table below.

15 ARBQ4000-00-B A EA 18 40 40 Effective area at exhaust side (mm2) S at P2 = 0.5 MPa 0.7 Outlet pressure (MPa) 0.6 B EB 37 19 37 0.5 Note 1) Set the pressure within the operating pressure range of the solenoid valve.

Cylinder side pressure (P2) I N I N O UT O UT Specifications 0.8 MPa 0.15 MPa 5 to 50C 0.60 dm3/(sbar) 180 c.p.m Maximum operating pressure Minimum operating pressure Ambient and fluid temp.

Plug-in type Cylinder side pressure P2 (MPa) The combination of VZS2150, VZS2250 and a double check spacer can be used as prevention of falling at the stroke end but cannot hold the intermediate position of the cylinder.

(mm) D1 Note) A Weight (g) 6-applicable tubing D2 P2 L2 L3 M P1 L1 Model L1 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KQ2ZT04-01S 18.5 54.5 50.5 25 31 44 27 33 46 56 54 62 P2 14 KQ2ZT04-02S 10.4 13.4 21 16 13.4 10.4 4 21.5 57.5 51.5 KQ2ZT04-03S 17 23.5 59.5 53.5 L2 P1 P1 D1 KQ2ZT06-01S 18.5 54.5 50.5 14 6 KQ2ZT06-02S 21.5 57.5 51.5 12.8 13.4 22 17 13.4 12.8 KQ2ZT06-03S

= 0.5 MPa Flow rate (l/min(ANR)) P B 35 16 15 ARBQ4000-00-B A EA 18 40 40 Effective area at exhaust side (mm2) S at P2 = 0.5 MPa 0.7 Outlet pressure (MPa) 0.6 B EB 37 19 37 0.5 Note 1) Set the pressure within the operating pressure range of the solenoid valve.

Warning Warning Caution External Pilot Pilot port 12(P1) and 10(P2) piping P1 and P2 piping should be as follows according to the model. Installing a silencer to the exhaust port and the bleed port is recommended for noise reduction and for dust entry prevention. Caution Mounting 1. Do not apply external force to the coil section.

Conversion equation V0 = (P1 x V1 P2 x V1)/P0 V0: Discharge volume L P1: Tank initial pressure MPa (Absolute pressure) V1: Tank capacity L P2: Tank pressure after release MPa (Absolute pressure) P0: Atmospheric pressure MPa (Absolute pressure) Note 1) If the regulator or the restrictor is installed right before the IN side of the valve, the valve may oscillate when it is turned off.

Vertical Operation P2 W A P1 a (c) (b) P0 P0 a W A (1) Speed is controlled by meter-out circuit. Using concurrently the meter-in circuit can alleviate the stick-slip. (1) Speed is controlled by meter-out circuit.

3 kPa)1 l/min (ANR) or less (at P2 = 0.4 MPa)0.6 l/min (ANR) or less (at P2 = 0.2 MPa)1.4 l/min (ANR) or less (at P2 = 0.6 MPa)1/4?5 to 60C (No freezing)?5 to 50C (No freezing)Bleed type0.5

3 kPa)1 l/min (ANR) or less (at P2 = 0.4 MPa)0.6 l/min (ANR) or less (at P2 = 0.2 MPa)1.4 l/min (ANR) or less (at P2 = 0.6 MPa)1/4?5 to 60C (No freezing)?5 to 50C (No freezing)Bleed type0.5