ZS-46-A1)], Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B (ZS-46-A2)]
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation
Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (
Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: B [Panel Mount Adapter, (ZS-46
Manual: w/o Operation Manual, w/o Calibration Certificate
Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B (ZS-46-A2)], Operation Manual: -
Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: None, Operation Manual: Operation
Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A2 [Bracket B (ZS-46-A2)], Operation
(B),2 (C),(B)(A), () (B)(C) (A) BLEED (B) (C) OUT SUP SUP. 1 1 M Pa/ m ( B) m 2 N / m m m M Pa M Pa/ m m M Pa B m /N (A) ) ( N N m / N ( C) m 2 N ( A) m 2 N -5- 3. 1 SUP OUT 2 %F.S 3 4 R B(P36202028) G 2 3 Rc,F N IR2000G43-2-01 G43-P2-N01-X30 IR2010G43-4-01 G43-P4-N01-X30 IR2020G43-10-01 G43-P10-N01-X30 021/44 Rc NNPT FG 00.0050.2MPa 1: 0.010.4MPa 20.010.8MPa
Pa/ m M Pa/ ( S) () m 2 1 1 m N MPa M Pa N m (A) / N ( B) /N () m 2 ( A) m 2 N -5- 1 SUP OUT 2 %F.S. 3 , 4 R B(P36201023) G 2 3 Rc,F N IR1000G33-2-01 G33-P2-N01-X30 IR1010G33-4-01 G33-P4-N01-X30 IR1020G33-10-01 G33-P10-N01-X30 011/84 Rc NNPT FG 00.0050.2MPa 10.010.4MPa 20.010.8MPa PRECI SI O N REG U LATO R I R101BG M AX.
Pa/ ( S) N N m 1 1 M Pa/m ( ) m 2 M Pa M Pa (A) /N (B) / ( ) m 2 ( A ) m 2 5- I R 3 0 0 1 SUP OUT 2 3%F.S. 3 R B(P36203018) G 2 3 RcF N IR3000G43-2-01 G43-P2-N01-X30 IR3010G43-4-01 G43-P4-N01-X30 IR3020G43-10-01 G43-P10-N01-X30 02:1/4 03:3/8 04:1/2 Rc FG NNPT 00.010.2MPa 10.010.4MPa 20.010.8MPa PRECI SI O N REG U LATO R I R302BG No.
Displ m Displ m Block diagram spring Compd. spring Compd. m M Pa MPa (A) m/N (B) m/N Force N Diaph.(C) m2 Daiph.(A) m 2 Force N -6- 3. How to order (Note 1) In the standard mounting position, the product name plate is attached to the front and the bracket is mounted to the back when viewed with the SUP side on the left and OUT side on the right. (Note 2) Accuracy: 3%F.S.
Displ m Displ m Block diagram spring Compd. spring Compd. m M Pa MPa (A) m/N (B) m/N Force N Diaph.(C) m2 Daiph.(A) m 2 Force N -6- 3. How to order (Note 1) In the standard mounting position, the product name plate is attached to the front and the bracket is mounted to the back when viewed with the SUP side on the left and OUT side on the right. (Note 2) Accuracy: 3%F.S.
Displ m Displ m Block diagram spring Compd. spring Compd. m MPa MPa (A) m/N (B) m/N Force N Diaph.(C) m2 Daiph.(A) m 2 Force N -6- 3. How to order (Note 1) In the standard mounting position, the product name plate is attached to the front and the bracket is mounted to the back when viewed with the SUP side on the left and OUT side on the right. (Note 2) Accuracy: 3%F.S.
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -