SMC Corporation of America
Elite Part Number Search
Search Results "ZSE10F-M5-B-GR"

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.  Up to 10 slave sensors can be set at once using the copy settings function.  Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., 2X, VACUUM SERIES, Auth/Grp: A/60, 645, ZSE30 VACUUM SWITCH

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.  Up to 10 slave sensors can be set at once using the copy settings function.  Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., PRESSURE SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X, OTHER

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X, OTHER NO SIZE RATING, 0.21671 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X, OTHER NO SIZE RATING, 0.21671 lb

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?, VACUUM SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X, OTHER

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A. Up to 10 slave sensors can be set at once using the copy settings function. Options include direct mount, panel mount or DIN rail mount, and a choice of 2 piping directions., VACUUM SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JC, ZSE30 1/

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, PRESSURE SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X, OTHER NO SIZE RATING, .11023 lb, ModelRated pressure rangeSet pressure range/Pressure display rangeWithstand pressureMinimum unit settingFluidPower supply voltageCurrent consumptionSwitch output--Repeat accuracyHysteresisAnalog outputDisplayDisplay

ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?, PRESSURE SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X, OTHER

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage)

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs)

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: A (NPN Open Collector 2 Outputs)

Pressure Range: F (-100.0 to 100kPa), Piping Specifications: 01 (R1/8 Piping Adapter, Side Ported), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage)

Pressure Range: -100.0 to 100kPa, Piping Specifications: M5 Female Thread/Rear Piping Port, Output Specifications: PNP Open Collector 1 Output+Analog Voltage, Unit Specifications: -, Lead Wire: -, Adapter: -, Calibration Certificate: -

Pressure Range: -100.0 to 100kPa, Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: NPN Open Collector 2 Outputs, Unit Specifications: -, Lead Wire: -, Adapter: -, Calibration Certificate: -

Pressure Range: -100.0 to 100kPa, Piping Specifications: R1/8 Piping Adapter, Side Ported, Output Specifications: PNP Open Collector 1 Output+Analog Voltage, Unit Specifications: -, Lead Wire: -, Adapter: -, Calibration Certificate: -

Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Analog Output Specification: -, Pipe Port Type: Female Thread, Plumbing Thread Type: M, Plumbing Thread Nominal: M5x0.8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 0.5, Operating Temperature Range(°C): -5~50, Operating Humidity Range(%): 35~85, Number

:GR-S-010(10g):GR-L-005(5g) 14 3-3. 2 (MHF2-8D2MHF2-12D20D) 1. 2. 8:12:R 1620:C ABC 3. (8:) (12 ) :GR-S-010(10g):GR-L-005(5g)GR-L-010(10g) 8 2 12 2.5 16 3 20 4 B C C 8 A 12 0.9 16 C MHF2-8D2 20 1.3 MHF2-12D* R MHF2-8D2 8 1.5 12 2 16 2.5 20 3 12 15 3-4. /1 MHF2-8DMHF2-8D1 1 16 2 17 3 18 4 19 5 20 NBR 6 21 NBR 7 8 A 9 B 10 C 11 12 13 14 15 MHF2-8D