SMC Corporation of America
Elite Part Number Search
Search Results "VV5K3-42-03-C6"

SX VK L C3 (3.2) C4 (4) C6 (6) M5 (M5 thread) VZ C6 (6) kit VF VFR N1 (1/8) N3 (5/32) N7 (1/4) N7 (1/4) VP7

KFG2H0425-01 KFG2H0425-02 KFG2H0403-01 KFG2H0403-02 KFG2H0604-01 KFG2H0604-02 KFG2H0806-01 KFG2H0806-02 KFG2H0806-03 KFG2H1075-02 KFG2H1075-03 KFG2H1075-04 KFG2H1008-02 KFG2H1008-03 KFG2H1008-04 KFG2H1209-02 KFG2H1209-03 KFG2H1209-04 KFG2H1210-02 KFG2H1210-03 KFG2H1210-04 KFG2H1613-03 KFG2H1613-04 8 14 8 14 10 16 18 24 36 34 41 67 33 40 66 33 40 66 30 38 63 51 67 19.4 23.8 19.4 23.8 20.9

Use of CC-Link enables you to freely configure any system from a single-axis system to an up to 42-axis system. Set the following values to the point table.

(Example) SS3YJA7-41-03-01. 1 set SYJA714 . 2 sets SYJ700-10-2A . 1 set (Example) SS3YJA5-40-03-01. 1 set SYJA514 . 2 sets SYJ500-10-3A . 1 set The asterisk denotes the symbol for assembly.

YA 03 YA-03 YA-05 18 20 6.8 9 16 20 6 8 42 50 6.5 6.5 10 12 Applicable air cylinder bore Bore size (mm) 32, 40 50, 63 03 05 32, 40 50, 63 U V W Mass (g) Part No.

Blanking plate assembly VVQ4000-10A-1 Individual SUP spacer VVQ4000-P-1Individual EXH spacer VVQ4000-R-102 03 02 03 Throttle valve spacer VVQ4000-20A-1 SUP stop valve spacer VVQ4000-37A-1 SUP/EXH block plate VVQ4000-16A Interface regulator ARBQ4000-00-1 A B P < EXH blocking plate > < SUP blocking plate > For exhaust cleaner mounting [-C ](1) Release valve spacer VVQ4000-24A-1D (1, 2) Double

04 03 04 32 16 By mounting individual SUP spacers on a manifold block, it is possible to provide individual supply ports for each valve. 1 P 40.3 1(P) 4(A) 2(B) 03: 3/8 04: 1/2 1(P') 5(R1) 3(R2) Circuit diagram Plug-in type Plug lead type Individual EXH spacer 179 (plug-in type) 133 (plug lead type) VVQ5000-R-1T (Plug-in type) VVQ5000-R-5T (Plug lead type) 03 04 03 04 32 16 By mounting individual

) 3 5 1 38 (53) 23 (30) 32 (42) 1 23 (30) 1/8 14 port 3/8, 1/2, 3/4-2 port 3, 5 port 30 (42) 30 (42) 1/8 14 port 3/8, 1/2, 3/4-2 port 3, 5 port 30 (42) 30 (42) 3/8, 1/2, 3/4 1 port 3/8, 1/2, 3/4 1 port Dimension inside is for rubber seal.

2 3 4 5 6 7 8 9 U side VQC 3 m SQ SQ1000-10A-3 SQ1230-5-C6 SQ1230-5-C6 SQ1230-5-C6 VQ0 SQ1230-5-C6 SQ1130-5-C6 SQ1130-5-C6 SQ1130-5-C6 VQ4 SQ1130-5-C6 D-sub connector cable AXT100-DS25-030 VQ5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VQZ Cylinder port fitting

YA-03 Joint . YU-03 CQ2 RS RQ T2 V M W CQM Joint and Mounting Bracket (A and B Types) Part No.

VX3324-03 VX3234-03 VX3334-03 VX3244-03 VX3344-03 6 0.33 0.5 4 9 0.19 2.2 3.4 3 8 0.33 3 6 (10A) Option Material 0.5 4 9 No.

The life of battery is five years from the production date regardless of the connection. (2) Configuration Positioning module I/O module QD75 QX40 41 42 QY40 41 42 50 A1SD75 AX40 41 42 AY40 41 42 FX2N-1GP FX2N-10PG FX2N-10GM FX2N-20GM FX2N(c) series FX3U(c) series Programmable controller Servo amplifier PC or PLC...etc Driver QD75 etc.

Mounting bracket A type mounting bracket B type mounting bracket Joint YA YB YU 18 6.8 16 6 42 6.5 10 YA-03 32, 40 20 9 20 8 50 6.5 12 YA-05 50 Bore size (mm) U V W Weight (g) Part no.

21.7 21.7 Screw-in connection S type: White color L type: Black color (Mounting hole) B C D E F G H Model A 3 8 Rc3 8 Rc3 8 Rc3 8 ZH18DS-03-03-03 ZH18DL-03-03-03 ZH20DS-03-04-04 ZH20DL-03-04-04 Rc 133 52.45 42 19 3.5 19 20.95 20.95 133 52.45 42 19 3.5 19 151.1 60.95 47.7 19 3.5 24 26.75 151.1 60.95 47.7 19 3.5 24 26.75 I J K L M N O Model 3 8 Rc3 8 Rc3 8 Rc1 2 Rc1 2 ZH18DS-03-03-03 ZH18DL

Nijverheidsstraat 20 B-2160 Wommelgem Belguim TEL: 03-355-1464 FAX: 03-355-1466 TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd. 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN TEL: 03-322-3443 FAX: 03-322-3387 POLAND SMC Industrial Automation Polska Sp.z.o.o. ul.

KQ2 KFG2H0425-01 KFG2H0425-02 KFG2H0403-01 KFG2H0403-02 KFG2H0604-01 KFG2H0604-02 KFG2H0806-01 KFG2H0806-02 KFG2H0806-03 KFG2H1075-02 KFG2H1075-03 KFG2H1075-04 KFG2H1008-02 KFG2H1008-03 KFG2H1008-04 KFG2H1209-02 KFG2H1209-03 KFG2H1209-04 KFG2H1210-02 KFG2H1210-03 KFG2H1210-04 KFG2H1613-03 KFG2H1613-04 1/8 1/4 1/8 1/4 1/8 1/4 1/8 1/4 3/8 1/4 3/8 1/2 1/4 3/8 1/2 1/4 3/8 1/2 1/4 3/8 1/2 3/8

(42) AS32l1FG-02-12(S)A 12 18.5 29.7 40 34.5 17 43 (43) AS32l1FG-03-06(S)A 6 10.4 21.8 32.1 36.4 50 48.4 44.5 42.9 1/4 19 16.6 13.3 29 (30) AS32l1FG-03-08(S)A 8 13.2 22.7 33 14.2 AS32l1FG-03-10(S)A 10 15.9 26.7 37 28 15.6 30 (31) AS32l1FG-03-12(S)A 12 18.5 29.7 40 26.8 17 32 (33) AS42l1FG-04-10(S)A 10 1/2 24 (23.8) 10.4 21.8 32.1 28.7 42.3 40.7 37.1 35.5 3/8 19 16.6 15.9 18.8 27.4 40.3 (

04 03 04 32 16 By mounting individual SUP spacers on a manifold block, it is possible to provide individual supply ports for each valve. 1 P 40.3 1(P) 4(A) 2(B) 03: 3/8 04: 1/2 1(P') 5(R1) 3(R2) Circuit diagram Plug-in type Plug lead type Individual EXH spacer 179 (plug-in type) 133 (plug lead type) VVQ5000-R-1T (Plug-in type) VVQ5000-R-5T (Plug lead type) 03 04 03 04 32 16 By mounting individual

Temperature sensor Remote type 3-color display Digital flow monitor CAT.ES100-80C Series PF3W IP65 Digital Flow Switch for Water 40% 40% smaller than existing product Reducing piping space PF3W704-03 66.4 70 Shortened PF2W704-03 (Existing product) 30 50 Straight piping length PF3W704 42 PF2W704 Existing product requires a straight piping length at least 8 times the piping diameter.