SMC Corporation of America
Elite Part Number Search
Search Results "VV5FR2-10-101-02T"

10 15 15 20 20 2 pcs. 5 10 15 10 20 15 Auto Switch Mounting Bracket Part Nos.

1.0 M3 x 8 0.63 M4 x 10 1.5 8 7.5 19 M4 x 0.7 7.5 46 30 3.7 11 42 NY M2.5 x 10 1.0 M3 x 8 0.63 M4 x 10 1.5 8 7.5 19 M3 x 0.5 5.5 45 30 5 11 38 NX M2.5 x 10 1.0 M3 x 8 0.63 M4 x 10 1.5 8 4.5 19 M4 x 0.7 7.5 46 30 3.7 11 42 NM1 M3 x 5 0.63 M3 x 8 0.63 M4 x 10 1.5 5 11.8 19 3.4 7.0 31 28 3.5 8.5 42 NM2 M2.5 x 10 1.0 M3 x 8 0.63 M4 x 10 1.5 6 48 19 3.4 7.0 31 28 3.5 8.5 42 25 NZ M3 x 12 1.5

List of Parameters.10-2 10.1 List of Parameters.10-2 10.1.1 Utility Functions.10-2 10.1.2 Parameters.10-3 10.1.3 MECHATROLINK-III Common Parameters.10-37 10.2 Parameter Recording Table.10-45 1.

B 9 18 () 22 10 SOL. A 23 6 () 11 Station 8 SOL.

12 16 5, 10, 15, 20 25, 30 7-4-20 20 25 5, 10, 15, 20 25, 30, 35, 40 45, 50 Series CQS 12, 16 20, 25 12 16 20 25 5, 10 7-4-12 Solid state switch D-M9N/M9NV D-M9P/M9PV D-M9B/M9BV D-F9NW/F9NWV D-F9PW/F9PWV D-F9BW/F9BWV D-F9BAL Series CQSK 12 16 5, 10, 15, 20 25, 30 7-4-28 20 25 5, 10, 15, 20 25, 30, 35, 40 45, 50 Series CQSS 12 16 5, 10, 15, 20 25, 30 (1) 7-4-36 20 25 5, 10, 15, 20 25, 30,

10 12 16 20 5 6.5 8 10 14 15 18 20 7 10 12 14 4 4 5 5 5 5 8 10 * Refer to P.2.3-18 for detail of the rod end nut and mounting brackets.

COM 10 LZR 9 6 LB B phase pulse detector (Differential line driver) LG 3 7 LBR Control common SD Plate 34 LG Control common 10 m or less Note 5) 33 OP Z phase pulse detector (Open collector) 1 P15R Plate SD 10 m or less 2 m or less Note 4) CN1 EMG Emergency stop 42 SON 15 Servo ON CN6 Note 4) RES 19 Reset 3 MO1 PC 17 Proportion control Analog monitor 1 10 VDC 1 LG TL 18 External torque limit

TdH9 TB +0.036 0 +0.036 0 +0.043 0 CLG-020-24 CLG-025-24 CLG-032-24 CLG-040-24 20 25 32 40 42 48 53 60 10 10 10 10 5.5 5.5 6.6 6.6 31 37 38.5 42.5 40 47 47 55 20 25 32 40 36 43 50 58 10 10 10 10 5.5 5.5 6.6 6.6 25 30 35 40 (29.3) (33.1) (40.4) (49.2) 8 10 12 14 8 10 12 +0.043 0 14 CG-020-24A CG-025-24A CG-032-24A CG-040-24A Applicable bore size (mm) Applicable bore size (mm) Part no.

TdH9 TB +0.036 0 +0.036 0 +0.043 0 CLG-020-24 CLG-025-24 CLG-032-24 CLG-040-24 20 25 32 40 42 48 53 60 10 10 10 10 5.5 5.5 6.6 6.6 31 37 38.5 42.5 40 47 47 55 20 25 32 40 36 43 50 58 10 10 10 10 5.5 5.5 6.6 6.6 25 30 35 40 (29.3) (33.1) (40.4) (49.2) 8 10 12 14 8 10 12 +0.043 0 14 CG-020-24A CG-025-24A CG-032-24A CG-040-24A Applicable bore size (mm) Applicable bore size (mm) Part no.

Purchasing order is available in units of 10 pieces. d d KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 4 6 8 10 5/32" 1/4" 5/16" 3/8" 16 18 32 35 39 43 16 18 32 35 39 43 6 8 10 12 6 8.5 10 20.5 22 20.5 22 11.5 Port plug VVQ1000-58A The plug is used to block the cylinder port.

535 1 5 10 20 50 1 5 10 20 50 16-11-13 10 For details about certified products conforming to international standards, visit us at www.smcworld.com.

Width across flat Effective area (mm2) Weight (g) L M d Model 2 x Applicable tubing H1 H2 I.D. 2.5 3 4 6 7.5 8 9 10 13 H1 H2 H2 4 4 6 8 10 10 12 12 16 KFG2H0425-00 KFG2H0403-00 KFG2H0604-00 KFG2H0806-00 KFG2H1075-00 KFG2H1008-00 KFG2H1209-00 KFG2H1210-00 KFG2H1613-00 1.8 2.3 3.3 5.3 6.8 7.3 8 9 12 7 11 25 43 42 44 42 71 1.6 2.6 6 17 30 35 45 57 101 8 8 21.8 5 d 10 14 10 14 24.8 28.6 5.8 6.6

Supply a voltage of 24 VDC 10% to the product. PWR: Green flashing Power supply voltage is abnormal. Check that a voltage of 24 VDC 10% is applied. Power supply voltage is abnormal. Check that a voltage of 24 VDC 10% is applied. ST: Green flashing Short circuit on input or output ports. Check for a short circuit on the devices connected to the Air Management Hub rear side.

Supply from one side 8 10 10 M5 x 0.8 Supply from both sides 10 12 12 Note) These values are obtained under the standard supply pressure.

1.5 M10 x 1.25 0 0.039 32 10 8 16 50 154 16 7 88 M32 x 2 14 24 41 Up to 300 22 21 84.5 46.5 29.8 42.5 21.5 M14 x 1.5 With Rod Boot (mm) l JW JH h B3 e f Bore size (mm) 1 to 50 1 to 50 51 to 100 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 (Reference) (Reference) 20 25 32 40 30 36 81 93 106 131 156 25 37.5 50 75 100

(Additional range) Relation between analog input and digital display Set value A B 0.002 0 kPa 2 kPa -0.1 0 kPa -101 kPa F0.1 -100 kPa 100 kPa 0.1 0 kPa 100 kPa 0.5 0 kPa 500 kPa 1 0 MPa 1 MPa 2 0 MPa 2 MPa 5 0 MPa 5 MPa 10 0 MPa 10 MPa 20 0 MPa 20 MPa 25 0 MPa 25 MPa USEr Input value (setting) Input value (setting) Available display unit and minimum set value Pressure range Rated pressure

PSE3 Applicable pressure sensor For compound For vacuum For low pressure For positive For low differential Rated pressure range -100 to 100 kPa 0 to -101 kPa 0 to 100 kPa 0 to 1 MPa 0 to 500 kPa 0 to 2 kPa Set pressure range 1 -101 to 101 kPa 10 to -101 kPa -10 to 100 kPa -0.1 to 1 MPa -50 to 500 kPa -0.2 to 2 kPa Set pressure resolution 0.2 kPa 0.1 kPa 0.1 kPa 0.001 MPa 1 kPa 0.01 kPa

VXA223 VXA224 VXA225 VXA226 VXA226 0.5 1.0 1.0 170 0.5 1.0 0.6 0.2 0.1 1.0 0.6 0.2 0.1 0.1 4.5 15 0.61 2.5 10.45 0.75 1 4 250 (8A) 26 41 46 15 26 41 58 58 1.1 1.7 1.9 0.61 1.1 1.7 2.4 2.4 3.3 6.4 8.8 2.5 3.3 6.4 11 11 0.50 0.40 0.40 0.45 0.50 0.40 0.38 0.38 1.1 1.8 2.3 0.75 1.1 1.8 2.8 2.8 6 8 1.5 0.4 340 10 4.5 6 8 250 1.0 3 8 (10A) 340 0.4 10 10 1 2 (15A) 420 Note) Refer to Glossary on