Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the
Port plug mounting port G Nil A B None A port B port 121 Manifold Specification Sheet Series SQ2000/Plug-in Unit Date: / / Manifold Model F P J T L S Customer name Contact person D E SS5Q23 Specification sheet no. Purchase order no. Equipment name Quantity set(s) Required date (Circle to specify.) Specifications U side Indicate required stations with a ."
Applicable model 02 03 04 06 10 1/4 3/8 1/2 3/4 1 8 3 Pressure gauge 3 4 5 6 1 AMR300-02/03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 3 4 5 6 1 2 Nil E2 E3 E4 E6 E10 None None With pressure switch S Nil 4 3 1/4 3/8 1/2 3/4 1 Port size Adapter assembly Thread type Symbol Port size Nil N F Rc NPT G Thread type 02 03 04 06 10 1/4 3/8 1/2 3/4 1 The port size of adapter assembly is same as the
E 3 Auto drain Additional symbol Port size 1 None With auto drain 0 Flow direction: left to right MR unit Flow direction: right to left 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Applicable model AMR300-02 to 03 AMR400-02 to 04 AMR500-04 to 06 AMR600-10 R 3 4 5 6 Body size 3 4 5 6 Adapter ass'y port size (2 pcs.) 8 3 standard standard standard Pressure switch 1 2 E2 E3 E4 E6 E10 None With pressure
E 3 Auto-drain Pressure gauge mounting Port size 02 03 04 06 10 ARJ MR unit 1 None With auto drain 0 Flow direction: Right to left Nil Flow direction: Left to right Applicable model 1/4 3/8 1/2 3/4 1 Nil E2 E3 E4 E6 E10 R 3 4 5 6 AMR3 00-02 to 03 AMR4 00-02 to 04 AMR5 00-04 to 06 AMR6 00-10 AR425 to 935 Adapter assembly port size (2 pcs.)
How to Order Type 40 1(P) port Stations VV5Z3 05 40 2 M5 Rc 1/8 4(A), 2(B) port size 1(P), 3/5(R) port thread type 02 2 stations 3, 5(R) port M5 M5 x 0.8 Nil Rc 4(A), 2(B) port Rc 1/8 F G 20 20 stations M5 x 0.8 N NPT Z NPTE How to Order Type 41 VV5Z3 05 41 1 M5 Applicable solenoid valve Stations 4(A), 2(B) port size 1(P), 3/5(R) port thread type 3/5(R) port 02 2 stations G L M D G L M
Class Instance Attribute Description Value 01h (01) 01h (01) MAC ID (Node address) 0 to 63 03h 0: 125 kbps 1: 250 kbps 2: 500 kbps (DeviceNetTM) 01h (01) 02h (02) Baud_rate (Communication speed) : The address and communication speed set in SW mode will be kept even after the DeviceNetTM communication power supply to the SI unit is turned off.
(mm) 0. 3 0. 5 0. 7 21. 2 6 3 6.36 10.6 14.7 66 10 4 19.8 33 46.2 172 16 6 51.6 86 121 264 20 8 79.2 132 185 412 25 10 124 206 288 691 32 12 207 346 484 c) Spring retracted type [C(D)U(K)*-*S] (N ) Operating pressure Mpa Bore size (mm) Rod O.D. (mm) Operating direction Pressure receiving area (mm2) 7 0. 3 0. 5 0.
NTJ-015A NT-02 NT-04 NT-05 12 M5 X 0.8 4 8 9.2 7.8 H B 20 M8 X 1.25 5 13 15.0 12.5 32, 40 M14 X 1.5 8 22 25.4 21.0 50, 63 M18 X 1.5 11 27 31.2 26 Electrical Wiring Output style Input/Output The output signal of the stroke reading cylinder is A/B phase difference output (open collector output) as shown in the figure below.
Operating pressure (MPa) Bore size (mm) Operating direction Piston area (mm2) 0.2 10 8 23 17 40 30 63 47 98 72 161 121 251 188 0.4 20 15 45 34 80 60 126 94 196 143 322 241 502 377 0.3 15 11 34 25 60 45 94 71 147 107 241 181 377 283 0.7 35 26 79 59 141 105 220 165 343 251 563 422 879 659 0.6 30 22 68 50 121 90 188 141 294 215 482 362 754 565 0.5 25 19 57 42 101 75 157 118 245 179 402 302 628
N Backlash Manual unlocking Theoretical Output 12 16 20 40 Rear end only 125 211 29 53 82 329 1mm Non-locking type only Standard Strokes (N) Operating pressure (MPa) Bore size (mm) Operating direction Piston area (mm) Bore size (mm) Standard stroke (mm) 0.2 10 8 23 17 40 30 63 47 98 72 161 121 251 188 0.4 20 15 45 34 80 60 126 94 196 143 322 241 502 377 0.3 15 11 34 25 60 45 94 71 147 107
Mounting position U U side SY5000 SY3000 D D side Symbol Port size 4 One-touch fitting C4 Symbol Port size 4 One-touch fitting C4 6 One-touch fitting C6 Mixed M 6 One-touch fitting C6 Valve stations 8 One-touch fitting C8 Mixed M Stations Symbol Note Single wiring specifications (up to 16 solenoids are possible) Indicate mixed specifications separately on a manifold specification sheet. 02
Metric size*1 Inch size*1 Type 02 2*3 23 3.2*2 04 4 06 6 01 1/8" 03 5/32" 2 Elbow Control type*1 0 Meter-out 1 Meter-in *1 Metric size: Light gray Inch size: Orange *1 Meter-out and meter-in types can be visually identified by the color of the knob. Meter-out: Gray Meter-in: Light blue *2 Use 1/8" tubing. *3 Only polyurethane tubing is applicable for 2.
Applicable bore (mm) d H1 B1 C1 4T counterbore A' 6 10 16 20 25 32 NTP-006 NTP-010 NTJ-015A NT-015A NT-02 NT-03 M3 x 0.5 1.8 2.4 4 5 5 6 5.5 7 8 10 13 17 6.4 8.1 9.2 11.5 15.0 19.6 S + Stroke Auto switch M4 x 0.7 Z + Stroke M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.25 Bore size (mm) A A' B C D E GA GB H J K L MM NN P Q QA 6 10 16 20 25 32 7 10 11 12 15.5 19.5 10 10 11.5 12.5 13 12.5 12.5 14 18
377 283 10 8 23 17 40 30 63 47 98 72 161 121 251 188 50 37 113 84 201 150 314 235 490 358 804 603 1,256 942 8 Stud Bolt Part No. 12 Bore size (mm) Part no. 16 8 MT-S8 12 MT-S12 20 16 MT-S16 25 20 MT-S20 25 MT-S25 32 32 MT-S32 40 40 MT-S40 Replacement parts for rod end male thread.
Specifications Max. operating pressure Min. operating pressure
AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.
AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 2. Speed adjustment is possible with meter-in/meter-out type speed controllers, but it may not be possible to obtain the cushion effect (smooth start-up, soft stop). 3.
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.