SUP/EXH block Note 1) SSQ1000-PR-3-C8-(S) Back pressure check valve Note 2) SSQ1000-BP SUP block plate SSQ1000-B-P EXH block plate SSQ1000-B-R Port plug Note 3) P R A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B Note 4) C3 (N1) With 3.2 (1/8") One-touch fitting C4 (N3) With 4 (5/32") One-touch fitting C6 (N7) With 6 (1/4") One-touch fitting
-A B310L B410L Y30 Y40 189 Y30L Y40L 133 Y40T For ITV10, use a modular adapter (Refer to page 585 for details). eL-bracket Accessories (Option)/Part No. 178 [Bracket] qAF30-A wAFM30-A Part No.
0 B 101 kPa C 10.1 kPa Rated pressure range Range Analog output [mA] 5 20 Analog output [V] For vacuum For compound pressure 100 kPa to 100 kPa 100 kPa 100 kPa 0 to 1 MPa 0 1 MPa 0.1 MPa For positive pressure 0 to 500 kPa 0 500 kPa 50 kPa 1 0.6 4 ZSE ISE A C B A B Pressure Pressure ZSP Dimensions PS PSE56, PSE5601 02 N01 N02 ISA A 11.5 3025 37.5 24 5.5 30 24 PSE 14 B 5.1 20 5 IS ISG Air
Using a regulator on the secondary side When mounting a regulator on the secondary side (A port side), use a residual pressure relief regulator (AR2550 to 4050) or a check type regulator (AR2560 to 6060). With a standard regulator (AR1000 to 6000), the secondary side pressure may not be released when this valve is exhausted. 5.
bore 1/8 R 4-R 4-R 36.8 E 36.8 E R P VEX P D D AMR + + MADE IN JAPAN ITV MADE IN JAPAN SMC SMC IC VBA Model Port size A B C D E G H I VE K L M N P Q R AV2000-02-G AV2000-02-GS AV2000-02-D AV2000-02-DZ AV2000-02-Y AV2000-02-YZ AV3000-03-G AV3000-03-GS AV3000-03-D AV3000-03-DZ AV3000-03-Y AV3000-03-YZ AV4000-04-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000-G AV5000
K L M N P Q R AV2000-02-G AV2000-02-GS AV2000-02-D AV2000-02-DZ AV2000-02-Y AV2000-02-YZ AV3000-03-G AV3000-03-GS AV3000-03-D AV3000-03-DZ AV3000-03-Y AV3000-03-YZ AV4000-04-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000-G AV5000-GS AV5000-D AV5000-DZ AV5000-Y AV5000-YZ M4 x 0.7 Depth 4.5 22 29 0 38 40 31 105 93 66 1/4 47.5 23.5 65.5 6 M4 x 0.7 Depth 4.5 22 29
Recommended speed controller Model Elbow type 10-AS2201F-01-06-X214 10-AS2201F-02-06-X214 10-AS2201F-02-06-X214 10-AS3201F-02-08-X214 10-AS3201F-02-08-X214 Model Straight type 10-AS2301F-01-06-X214 10-AS2301F-02-06-X214 10-AS2301F-02-06-X214 10-AS3301F-02-08-X214 10-AS3301F-02-08-X214 In-line type 10-AS2001F-06-X214 10-AS2001F-06-X214 10-AS2001F-06-X214 10-AS3001F-08-X214 10-AS3001F-08-X214
Operation of the cylinder with its body fixed will damage the wear ring, resulting in increase of particle generation or malfunction. 12-REA40 10-AS2001F-06-X214 10-AS2201F-02-06-X214 10-AS2301F-02-06-X214 12-REA50 10-AS3001F-08-X214 10-AS3201F-02-08-X214 10-AS3301F-02-08-X214 12-REA63 10-AS3001F-08-X214 10-AS3201F-02-08-X214 10-AS3301F-02-08-X214 Although speed adjustment is possible with
Refrigerant R134a (HFC) IDU E Drainage is discharged by controlling a solenoid valve with a timer. A strainer for solenoid valve protection and a stop valve are also included. (The external dimensions are the same as the standard product.)
Use caution to the popping of a snap ring. When replacing rod seals and removing and mounting a snap ring, use a proper tool (snap ring plier: tool for installing a type C snap ring). Even if a proper tool is used, it is likely to inflict damage to a human body or peripheral equipment, as a snap ring may be flown out of the tip of a plier.
(Looked by double solenoid valve) (Looked by double solenoid valve) SOL. location B (*) B (*) B B A B A B A B A B A A A A B A B A SOL. location VQC 3 position 3 position Double Double Double Double SI unit Single Single SI unit Single Single SQ Stations 1 2 3 4 5 Stations 1 2 3 4 5 VQ0 The places of asterisk are not used.
8 1 2 2 x 3 4 2 x 1 1 8 3 x 3 x VNH1 -10A VNH2 -15A VNH3 -20A VNH4 -25A 2 x 2 x A B A B A B A B 60 80 100 115 235 (221) 264.5 (250.5) 300 (286) 319 (305) 60 77 96 113 46 60 76 85 34 40 50 60 24 36 41 50 135 164.5 200 219 50 60 79 90 77 95.5 111 119 1 8 VNC 1 4 1 4 VNH Note) ( ): CE compliant product (-Q) VND Model J K L M N O P Q R S T U V VNH1 -10A A B VNH2 -15A A B VNH3 -20A A B VNH4 -
Description B VNH1 VNH2 VNH3 VNH4 VNH1-16 VNH2-16 VNH3-16 VNH4-16 Bracket (with bolt and washer) 4.2-30 VNH Specifications 3 port valve 2 port valve A B A B VNH311 20A A B VNH411 25A A B VNH113 10A A B VNH213 15A A B VNH313 20A A B VNH413 25A A B VNH133 10A A B VNH233 15A A B VNH333 20A A B VNH433 25A A B VNH111 10A VNH211 15A Model Operating fluid pressure Fluid Operation 0 to 7.0MPa 0 to
[5m ] A B-1 2 L A A-1 1 B B-2 6 1 1.5m B A-2 5 COM-A/COM B-3 3 3 3m COM-B/ A-3 4 5 5m Shield Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6 B B-6 S 9 B A-6 8 3 14.2 2 1 (8) 14 18 B1 A1 17.7 5 6 2 1 A6 B6 15 16 11 30.7 112 [820m] A B-1 2 A A-1 1 L B B-2 6 8 8m B A-2 5 COM-A/COM B-3 3 A 10m COM-B/ A-3 4 B 15m Shield C 20m Vcc B-4 12 GND A-4 13 A B-5 7 A A-5 6
D-B5/B64 D-G5/K59 D-G5W/K59W (A set of band and screw) BA-02 BA-01 (A set of band and screw) BA-32 (A set of band and screw) BA-04 (A set of band and screw) BA-05 (A set of band and screw) BA-06 (A set of band and screw) BA-08 (A set of band and screw) BA-10 (A set of band and screw) Note) Since the switch bracket (made from nylon) are affected in an environment where alcohol, chloroform,
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
A A A A A Speed Home position A B C Speed no. Time Two pattern combination example (A five point movement of absolute move A and incremental move B) Acceleration no.
Operate the piston within a range such that collision damage will not occur at the end of the stroke. When a cylinder is used in a clamping mechanism, there is a danger of work pieces dropping if there is a decrease in clamping force due to a drop in circuit pressure caused by a power outage, etc.
This can cause a loss of holding force and malfunction. AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.
This can cause a loss of holding force and malfunction. AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.