0.5 1 5 10 20 50 0.5 1 5 10 20 50 Load (kN) Load (kN) Bore size 80 B rod C rod 2000 6 4 8 3 7 5 1 5 2 4 8 3 7 6 1 2 1000 Stroke (mm) 500 100 50 1 5 10 20 50 1 5 10 20 50 Load (kN) Load (kN) Bore size 100 B rod C rod 4 8 8 3 3 7 7 5 4 5 2000 6 6 1 2 1 2 1000 Stroke (mm) 500 100 50 1 5 10 20 50 100 1 5 10 20 50 100 Load (kN) Load (kN) 28 Series CH2E/CH2F/CH2G/CH2H Technical Data 3 Relationship
Insulation type Electrical entry Electrical option Class B G C D, T S Note) S L, Z 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) AC DC Note) Surge voltage suppressor is attached in the middle of a lead wire. 17-3-72 3 The VX series will be revised shortly.
02 FV4 MV4 TW4 FV6 MV6 TW6 No code P 06 10 1 to 60 psig (0.007 to 0.4 MPa) 2 to 100 psig (0.014 to 0.7 MPa) 5) Panel mounting hole: dia. 1.56 inch (39.6 mm).
R ZZM 06 06 R Multi-ejecter Common SUP port location Port and silencer location Series ZM Manifold Nil Both sides Number of stations R Right side L Left side B Both sides Right side Left side R L 01 1 station Right or left to the VAC port Right or left to the VAC port 05 5 stations Common EXH port size 10 10 stations (Max.) 04 06 1 2 3 4 Thread type S Silencer for ZZM (ZZM-SA) Nil Rc NPTF
Main Body Shape: Unit, Additional Function: Valves for Vacuum Generation / Vacuum Destructive Valve, Vacuum Port Connecting Port Shape: M5, Air Supply Port Connecting Shape: M5, Application: Manifolds, Suction Flow(l/min): 16, Electrical entry: L-type plug connector, Light/surge voltage suppressor: With light/surge voltage suppressor, Solenoid valve rated voltage: 24 V DC, Valve Type: N.C
for 3rd. value (0h) and then, perform (5).
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 8 Stations, Voltage: 5 (24 VDC)
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 9 Stations, Voltage: 5 (24 VDC)
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 1 Station, Voltage: 5 (24 VDC)
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 2 Stations, Voltage: 5 (24 VDC)
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 3 Stations, Voltage: 5 (24 VDC)
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 4 Stations, Voltage: 5 (24 VDC)
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 10 Stations, Voltage: 5 (24 VDC)
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 5 Stations, Voltage: 5 (24 VDC)
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 7 Stations, Voltage: 5 (24 VDC)
Main Body Shape: Unit, Additional Function: Valves for Vacuum Generation / Vacuum Destructive Valve, Vacuum Port Connecting Port Shape: M5, Air Supply Port Connecting Shape: M5, Application: Manifolds, Suction Flow(l/min): 16, Electrical entry: L-type plug connector, Light/surge voltage suppressor: With light/surge voltage suppressor, Solenoid valve rated voltage: 24 V DC, Valve Type: N.O
Main Body Shape: Unit, Additional Function: Valves for Vacuum Generation / Vacuum Destructive Valve, Vacuum Port Connecting Port Shape: M5, Air Supply Port Connecting Shape: M5, Application: Manifolds, Suction Flow(l/min): 16, Electrical entry: L-type plug connector, Light/surge voltage suppressor: With light/surge voltage suppressor, Solenoid valve rated voltage: 24 V DC, Valve Type: N.O
Main Body Shape: Unit, Additional Function: Valves for Vacuum Generation / Vacuum Destructive Valve, Vacuum Port Connecting Port Shape: M5, Air Supply Port Connecting Shape: M5, Application: Manifolds, Suction Flow(l/min): 16, Electrical entry: L-type plug connector, Light/surge voltage suppressor: With light/surge voltage suppressor, Solenoid valve rated voltage: 24 V DC, Valve Type: N.O
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 9 Stations, Voltage: 24 VDC, Electrical Entry: -, Blanking Plate: -, CE-compliant: -
Volume of Release Air Tank: V2: 0.8 cm³ (See Catalog for Calculation), Stations: 1 Station, Voltage: 24 VDC, Electrical Entry: -, Blanking Plate: -, CE-compliant: -