SMC Corporation of America
Elite Part Number Search
Search Results "VHS50-10A-S"

5A 5A 15A 10A 10A Compressor input 180/200W 50/60Hz 385/440W 50/60Hz Heater input 220W 420W Note 6) Nominal filtration rating 0.01m (99.9% filtration efficiencyNote 6) Buili-in filter specifications Cleanliness of the filter outlet side Particles of 0.3m or more: 3.5 particles/L(ANR)or less Note 6) Protective Overcurrent protection Overload relay devices Heater overheat prevention Thermostat

-2 VVQZ2000-10A-2 VVQZ3000-10A-2 This is used when removing the valve for maintenance, or reserving a valve mounting space on the manifold for future use.

C S S Motor Type S AC Servo motor Cable Content AC Cable Length (L) [m] SSCNET Cable S 0.15m L 0.3m K 0.5m J 1m 1 3m 3 c I/O Connector (For LECSS-S/LECSS2-T)-CS Driver Type LECSS S *LE-CSNS is 10126-3000PE (Connector)/ 10320-52F0-008 Shell kit of Sumitomo 3M Limited or equivalent goods.

Station Address MECHATROLINK-III Communication Baud Rate 100 Mpbs Transmission Cycle 125 s, 250 s, 500 s, 750 s, and 1.0 ms to 4.0 ms (increments of 0.5 ms) Number of Transmission Bytes 16, 32, or 48 bytes per station Use the DIP switch S3 to select the number of words.

Setting (byte) 1 to 65535 10 Pn80A 1st Linear Acceleration Constant 1 2 100 reference units/s2 its/s 1 to 65535 10 Pn80B 2nd Linear Acceleration Constant 1 2 100 reference units/s2 its/s 0 to 65535 100 reference units/s Pn80C Acceleration Constant Switching Speed 1 2 0 1 to 65535 10 Pn80D 1st Linear Deceleration Constant 1 2 100 reference units/s2 its/s 1 to 65535 10 Pn80E 2nd Linear Deceleration

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Dimensions GC GC S + (2 x Stroke) ZZ + (2 x Stroke) ZZ + Stroke (A + B) S + Stroke (A + B) Stroke B Stroke A Bore size (mm) GC 29 33 33 41 41 S 169 181 197 233 253 ZZ 231 250 269 321 342 40 50 63 80 100 GC 29 33 33 41

Port S (10) remains pressurized and valve S (18) remains open.

Reed switch Type Solid state switch Leakage current 3 wire: 10A or less 2 wire: 1mA or less None 1ms or less Note2) Actuation time 1.2ms Impact resistance 1000m/s{102G} 300m/s{30.6G} Switch operating position (ON) 50M or more with a 500VDC megohmmeter (between lead wire & case) Insulation resistance 1500VAC for 1 minute Note 1) (between lead wire & case) 1000VAC for 1 minute (between lead

Step (1) Precautions on Model Selection Warning Find the maximum load speed: V (mm/s) from the load movement time: t (s) and the movement distance: st (mm). 1.

LEHZ/LEHZJ: 5 to 50 mm/s LEHF10: 5 to 20 mm/s LEHF20/32/40: 5 to 30 mm/s LEHS: 5 to 50 mm/s Operation at the speed outside of the range can get the lead screw caught and cause operation failure. 9. Self-lock mechanism The product keeps a gripping force due to the self-lock mechanism in the lead screw.

S [S ] 2.S [S ] S S 1 () (0 ) (+) (+) 1 + mm (-) (-) 1 mm 1 mm/s 1 mm/s 2 1 INP mm 1 31 - mm 0mm M (0mm) 100mm 1 M (100mm) (+)(-) 1 1 +(++) 12 2 (+) SW SW SW 12 1. 2. W W 1 1 W W 2 2 1 1 11 11 12 12 1 32 - 7.3 () 12 1.CW [CW] 2.CCW [CCW] 12 1. [] 2.

(Example) Find the upper limit of rod end load when an air cylinder of 63 is operated at 500 mm/s.

P & S P A 0 1 1 3 43 y. qB siB s/B s/g 9a SP & SPA 0114 54 B B B B sP & sPA 0115 45 S s 2 MTNG HOLES I .FOOTPRINT' CLASS 1 SUB.PLATE MOUNTED 'SWAY VATVES '49 i.'8 (?

rod extension rod retraction OFF OFF OFF Locked stop SOL.A SOL.C SOL.B 0.5 s or more 0 to 0.5 s W ON OFF OFF Unlocked ON OFF ON Backward SOL.C SOL.B 2) [Vertical] Load in the direction of Load in the direction of SOL.B rod extension rod retraction SOL.A SOL.C W W SOL.A Note) The basic circuit examples are for spring locking (exhaust locking).