ends) Note: Minimum impact velocity tor PM nlodels it 4 itr/*c. 9k**k &"bs*rbers Non-Adjustable Hydraulic Series 49rc.
K-F-X60 LJ1H202NAStroke K-F-X60 Without motor Specifications Combinations other than the above cannot be manufactured.
LTF8F-K Symbol 2H 3H 2V 3V Motor capacity 100W 200W 100W 200W 1) 1) 2) 2) Note 2) Be sure to use a regenerative absorption unit (LC7R-K1A) with this controller (with brake).
Ma = K Mmax Work piece mounting coefficient K: Fig. 3 Allowable moment coefficient : Graph 2 Max. allowable moment Mmax: Table 4 Mar = 36 Mrmax = 36 K = 1 = 1 ' = 0.39/36 = 0.011 May = 1 x 1 x 18=18 Mymax = 18 K = 1 = 1 = 0.39/18 = 0.022 Find the load factor of the static moment.
BS + Stroke (mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 D 12 14 16 20 20 B1 17 19 22 27 27 C 54 68 86 104 124 B 24 28 32 39 50 BY 7 8 9 9 12 AL 19.5 23.5 27 32 32 BX 9 6.5 8 10 11 ET A 22 26 30 35 35 BS 37 45 44 54 53 K 5.5 5.5 6 7 7 BT Model MUWB25 MUWB32 MUWB40 MUWB50 MUWB63 Stroke range (mm) 5 to 300 5 to 300 5 to 300 5 to 300 5 to 300 M5
BS + Stroke (mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 D 12 14 16 20 20 B1 17 19 22 27 27 C 54 68 86 104 124 B 24 28 32 39 50 BY 7 8 9 9 12 AL 19.5 23.5 27 32 32 BX 9 6.5 8 10 11 ET A 22 26 30 35 35 BS 37 45 44 54 53 K 5.5 5.5 6 7 7 BT Model MUWB25 MUWB32 MUWB40 MUWB50 MUWB63 Stroke range (mm) 5 to 300 5 to 300 5 to 300 5 to 300 5 to 300 M5
Switch for setting address X1 and X10 3 B RATE Communication speed The switch to set the communication speed of the controller IF communication line.
K 0.3m L 0.5m 1 1m 4 Terminating Resistor Termination on RS-485 Bus (120 Ohms) Recommended connector :XS2C-D4** [OMRON Corporation] 120 1/4W 5 RJ-45 connector dust cover Dust adhere when the RJ-45 connector is not connected with the CN1 or CN2 connector.
A)(B) 4 2 5 1 3 (EA)(P)(EB) Double solenoid (FG-D) (Metal) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Double solenoid (FG-D) (Rubber) (A)(B) 4 2 5 1 3 (EA)(P)(EB) 3-position Closed center (FHG-D) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Exhaust center (FJG-D) (A)(B) 4 2 5 1 3 (EA)(P)(EB) Pressure center (FIG-D) (A)(B) 4 2 5 1 3 (EA)(P)(EB) 6 Series VS R8 Rubber Seal S HOW TO ORDER VALVE VS R 8 6 FG S 3EZ V1 A03T X1
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series LTF (Incremental encoder) H Applicable actuators Compatible actuator models LTF6ELTF8FLTF6E-K LTF8F-K Symbol 2H 3H 2V 3V Motor capacity 100W 200W 100W 200W 1) 1) 2) 2) Note 2) Be sure to use a regenerative absorption unit (LC7R-K1A) with this controller
LTF8F-K Symbol 2H 3H 2V 3V Motor capacity 100W 200W 100W 200W 1) 1) 2) 2) Note 2) Be sure to use a regenerative absorption unit (LC7R-K1A) with this controller (with brake).
Function Content 10 Sets the position of station numbers 100 and 10 1->10, A->100, B->110, C->120 1 Sets the position of station number 1 Example: When station number is 120: set C to x10 and 0 to x1 When station number is 111: set B to x10 and 1 to x1 HOLD/CLEAR switch: Sets the output status when the fieldbus has a communication error or is in idling state.
With shock absorber (1 pc. on port side) TN TF 20, 25, 32 BS The adjusting bolt is installed even when B or BS is selected.(Except 10) Standard stroke (mm) Refer to Standard Stroke on page 1529.
Relay, PLC Diagnostic indicator ( 2 color) 24V Yes J79W F7BWV 2 wire 12V Rod end male thread M Water resistant (2 color) F7BA Grommet 3 wire (NPN) With timer F7NT 5V 12V IC With diagnostic output (2 color) Latch with diagnostic output (2 color) F79F 4wire (NPN) F7LF 0.5m (Example) 3mL A80C A80CL A80CZ A80CN 5mZ (Example) N Lead wire length Solid state switches marked with a K
For further details, refer to mounting positions under Replacement heaters/Part Nos. on page 46. 24 High Vacuum Angle Valve Series XLD, XLDV Dimensions (mm) 1in=25.4mm XLDV-25/With solenoid valve 11 C Fn (KF flange) Fb (K flange) C Port R (exhaust port) K K 2.5 41.5 Initial exhaust solenoid valve Main exhaust solenoid valve G A B 8 10.5 Port P (pressure port) A Max 10.5 (except connector
For further details, refer to mounting positions under Replacement heaters/Part Nos. on page 46. 24 High Vacuum Angle Valve Series XLD, XLDV Dimensions (mm) 1in=25.4mm XLDV-25/With solenoid valve 11 C Fn (KF flange) Fb (K flange) C Port R (exhaust port) K K 2.5 41.5 Initial exhaust solenoid valve Main exhaust solenoid valve G A B 8 10.5 Port P (pressure port) A Max 10.5 (except connector
SD RD 24 V OV VCAM FG CAM Vt BS+ BDH BDL BSFG 24 V 0 V 24 V 0 V +24V 24G DA DB DG FG Description Description Description LED LED LED PWR. Light ON with transmission power input, light Off without it Green light ON with circuit power input PWR.
SD RD 24 V OV VCAM FG CAM Vt BS+ BDH BDL BSFG 24 V 0 V 24 V 0 V +24V 24G DA DB DG FG Description Description Description LED LED LED PWR. Light ON with transmission power input, light Off without it Green light ON with circuit power input PWR.
Back pressure check valve A 4 (A) 4 (B) 2 Built-in Nil K None A 2 B SOL.b SOL.a 3 (R) 5 (R) 1 (P) Pilot specifications 4 position dual 3 port valve: N.O./N.O. External pilot Nil R Internal pilot (A) 4 (B) 2 B Dual 3 port valves are not available with external pilot specifications. SOL.b SOL.a 3 (R) 5 (R) 1 (P) 4 position dual 3 port valve: N.C./N.O.