SMC Corporation of America
Elite Part Number Search
Search Results "VHS20-02-BS-R-D"

M TPH TPS A Connection threads R D Applicable tubing Applicable tubing O.D. mm H (width across flats) Weight g KPGH04-M5 KPGH04-01 KPGH04-02 KPGH06-M5 KPGH06-01 KPGH06-02 KPGH08-01 KPGH08-02 KPGH10-02 KPGH10-03 KPGH12-03 KPGH12-04 KPQH04-M5 KPQH04-01 KPQH04-02 KPQH06-M5 KPQH06-01 KPQH06-02 KPQH08-01 KPQH08-02 KPQH10-02 KPQH10-03 KPQH12-03 KPQH12-04 25.4 25.9 25.4 22.9 26.3 26.8 25.6 26.1

C1 Model (Stock item) Pressure range Note) Model Unit Connecting Note (kPa) GZ46-K-01 to 02 100 to 0 1 8 1 8 1 4 kPa R , kPa With covering assembly GZ46-K-01 to 02-C, C1 100 to 0 R ,1 4 1 8 1 4 kPa GZ46-K-01 to 02M 100 to 0 GZ46-K2K-01 to 02 100 to 200 R , M5 (Female thread) kPa GZ46E-K-01 to 02M 100 to 0 1 8 1 4 R , M5 (Female thread) R , 1 8 1 4 kPa Note) Do not apply pressure that exceeds

N02 NPT 1/4 NPT 3/8 Note 2) N03 N04 NPT 3/8 NPT 1/2 NPT 3/8 NPT 1/2 Note 1) AS220-02 Note 2) AS320-02 749 AS20-D Series Construction AS3200-02-D Meter-out M5 type U10/32 type Meter-in M5 type U10/32 type AS3210-02-D Component Parts No.

M a n i f o l d m o u n t e d v e r s i o n s o f t h e V YH y r e g a r e a v a i l a b l e .

Seal method: Sealant For R, NPT thread Indicator window direction: 0 Indicator window direction: 180 D3 W1 W2 X Y Applicable tubing O.D. d A L4 D1 L3 M L2 L1 T H (Width across flats) Metric Size [mm] Model d T (R, NPT) H D1 D3 L1 L2 L3 L4 Note 1) A Note 2) M W1 W2 X Y Weight [g] Unlocked Locked Unlocked Locked AS221FSG-01-23 (S) 3.2 7.2 13 (13) AS221FSG-01-04 (S) 4 8.2 AS221FSG-01-06 (S)

D side U side Stations 7 6 5 4 3 2 1 n [Communication connector D-sub] (DIN rail clamping screw) BUS OUT BUS R R R 76.7 76.7 62.5 BUS IN 58.7 3 3 3 X 12 X 12 X 12 40.5 B B B B B B B B PWR PWR P P P 25 1 1 1 A A A A A A A A A 18.5 9.5 7.5 56.9 13 20.5 (7.5) One-touch fitting [1(P), 3(R) port] 13.4 56.9 Applicable tube O.D.

(A) 2 (A) 1 (P) 3 (R) 2 (A) 2 (A) 3 (R) Model C[dm3/(s.bar)] b Cv C[dm3/(s.bar)] b Cv C[dm3/(s.bar)] b Cv C[dm3/(s.bar)] b Cv VEX312-01 VEX312-02 VEX332-02 VEX332-03 VEX332-04 VEX350-04 VEX322-01 VEX322-02 VEX342-02 VEX342-03 VEX342-04 1/8 1/4 1/4 3/8 1/2 1/2 1/8 1/4 1/4 3/8 1/2 2.4 3.5 4.1 8.7 9.8 24 3.3 4.1 8.1 12 13 0.19 0.35 0.36 0.29 0.37 0.32 0.34 0.28 0.34 0.26 0.20 0.59 0.89 1.1

AC (lZ) circuit DC (lU) circuit LED R NL R NL: Neon bulb R: Resistor LED: Light emitting diode, R: Resistor Note) The 24 VAC specifications are the same as those in the DC (lU) circuit diagram. DC (lZ) circuit + R D LED LED: Light emitting diode D: Protective diode R: Resistor Back page 3 Series VP Specific Product Precautions 4 Be sure to read before handling.

R port R port P port P port A, B port A, B port Type of connection Type of connection VV5Q11 VV5Q21 16 Series VQ1000/2000 Kit (D-sub connector) F VV5Q11 VV5Q21 D-sub connector reduces installation labor for electrical connections.

D Approx. 300 Q F G1/2 Width across flats H Width across flats H C E C E R R B A 2 x P Port size 2 x P Port size B A M M 2 x J thread depth K 2 x J thread depth K DIN terminal: D Conduit terminal: T S Q F 34 D Cable 6 to 12 (Q) F G1/2 D 25 Width across flats H Width across flats H T C M C R R E E (S) A 2 x P Port size A 2 x P Port size B B M 2 x J thread depth K G1/2 2 x J thread depth K

Connection thread 17 15.2 1 4 KGU08-02 18.5 8 15.2 3 8 KGU08-03 <R> 2-applicable tubing 1 4 KGU10-02 40 28.4 30 40 65 61 62 65 19 18.5 3 8 KGU10-03 21 10 18.5 1 2 KGU10-04 22 1 4 KGU12-02 64.5 65.5 68.5 57.4 45.4 32 40 65 3 8 KGU12-03 20.9 22 20.9 12 22 1 2 KGU12-04 Note) D: Max. diameter Reference dimensions after R thread installation.

Port size 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 4 ASD230F-M5 ASD330F-01 ASD430F-02 ASD530F-02 ASD530F-03 ASD630F-04 M5 x 0.8 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2 ASD230F-U10/32 ASD330F-N01 ASD430F-N02 ASD530F-N02 ASD530F-N03 ASD630F-N04 10-32 UNF NPT 1/8 NPT 1/4 NPT 1/4 NPT 3/8 NPT 1/2 Specifications Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1 MPa Min. operating pressure

1 2 KQ2D12-04S 45.1 48.5 63 MS D Reference dimensions after R thread installation.

0 q r !2 ASD q t AS y !3 r t AS-FE u w i KE i o AS-FG y !0 u AS-FP w e AS-FM Meter-in type Meter-out type !4 !1 Meter-in type Meter-out type AS-D Seal method: Sealant For R, NPT thread Seal method: Sealant For R, NPT thread AS-T e !1 ASP !0 o q r ASN !2 t AQ q w ASV r y AK u t VCHC i i ASR ASQ !

Elbow type Universal type Port size Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS121F-M5 AS131F-M5 M5 x 0.8 AS221F-01 AS231F-01 R 1/8 AS221F-02 AS231F-02 R 1/4 AS321F-02 AS331F-02 R 1/4 AS321F-03 AS331F-03 R 3/8 AS421F-04 AS431F-04 R 1/2 AS121F-U10/32 AS131F-U10/32 10-32 UNF AS221F-N01 AS231F-N01 NPT 1/8 AS221F-N02 AS231F-N02 NPT 1/4 AS321F-N02 AS331F-N02

: X port) + 58 [65] 54.5 42.6 VP 26 20 X S070 1/4, 1/8 (P, R port) 23 15 48 VQ VKF VQZ L plug connector (L): SYJ74-LM plug connector (M): SYJ74-M01 02 01 02 DIN terminal (D): SYJ74-D01 02 M8 connector (WO): SYJ74-WO01 02 VZ VS VFN Applicable cable O.D. 3.5 to 7 Approx. 300 (Lead wire length) 89.6 Max. 10 58 [65] 91.5 84 42.6 62.5 72.7 M8 x 1 45 69.1 [76.1] Approx. 300 (Lead wire length) Pg7

M plug connector 2 position double: VZS3250-M(Z)-01 02 3 position closed center: VZS3350-M(Z)-01 02 3 position exhaust center: VZS3450-M(Z)-01 02 3 position pressure center: VZS3550-M(Z)-01 02 DIN terminal 2 position double: VZS3250-D(Z)-01 02 3 position closed center: VZS3350-D(Z)-01 02 3 position exhaust center: VZS3450-D(Z)-01 02 3 position pressure center: VZS3550-D(Z)-01 02 164 (3 position