SMC Corporation of America
Elite Part Number Search
Search Results "VDW31-5G-1-P7-A-K-XF"

Default: Gain 9 Bit Bit 3, 2, 1, 0 Value Bit 3 2 1 0 Setting 0 0 0 0 Gain 0 0 0 0 1 Gain 1 0 0 1 0 Gain 2 0 0 1 1 Gain 3 0 1 0 0 Gain 4 0 1 0 1 Gain 5 0 1 1 0 Gain 6 0 1 1 1 Gain 7 1 0 0 0 Gain 8 1 0 0 1 Gain 9 * 1 0 1 0 Gain A 1 0 1 1 Gain B 1 1 0 0 Gain C 1 1 0 1 Gain D 1 1 1 0 Gain E 1 1 1 1 Gain F * indicates the initial shipping value. 16 - Parameter index 0x43 Parameter name Sensitivity

Tube with a piping internal diameter of 6.5 (1/4") or above and a length of 5 m (200 inch) or less. 8) Pipework for auto drain discharge which rises higher than the auto drain outlet should be avoided. It may cause the auto drain operation to fail. 5 - Air Source Warning 1) Use clean air.

Part No.: X L 1 A 2 1 0 1 Table 1. Valve size Table 2. Seal material option Applicable product No. Symbol Standard Nil Optional Refer to XLA/XLC-16-2 16 Table 3 XLA/XLC-25-2 25 XLA/XLC-40-2 40 XLA/XLC-50-2 50 XLA/XLC-63-2 63 XLA/XLC-80-2 80 Note 1) Bellows assembly contains the valve seal 1.

Tube with a piping internal diameter of 6.5 (1/4") or above and a length of 5 m (200 inch) or less. 8) Pipework for auto drain discharge which rises higher than the auto drain outlet should be avoided. It may cause the auto drain operation to fail. 5 - Air Source Warning 1) Use clean air.

PART NAME QTY AFF75A AFF125A AFF150A AFF220A 1 CASE 1 2 COVER 1 3 GASKET 1 AL-33S AL-34S AL-35S ELEMENT (for FILTRATION RATING Symbol Nil ) 1 EC700-003N EC800-003N EC900-003N 4 ELEMENT ( for FILTRATION RATING Symbol X13 ) 1 EC700-X30NX0 EC800-X30NX0 EC900-X30NX0 5 HEX.BOLT(M12) 12 6 SPRING WASHER 12 7 PLUG(1/4) 2 8 PLUG(1/4) 2 -6- FGX-OM-P003-A 3.Specifications 1How to Order Filtration rating

Tube with a piping internal diameter of 6.5 (1/4") or above and a length of 5 m (200 inch) or less. 8) Pipework for auto drain discharge which rises higher than the auto drain outlet should be avoided. It may cause the auto drain operation to fail. 5 - Air Source Warning 1) Use clean air.

VXF*-OML0001-A PRODUCT NAME Valve Controller MODEL / Series / Product Number VXFC06D VXFC10D VXFC06D-6 VXFC10D-6 Contents 1. Safety Instructions P2-5 2. Specifications P6 3. Name of Parts P7-8 4. Wiring P9 5. Description of operation P10-11 6. Cascade connection P12-13 7.

Setting of DIP switch for temporary stop. 1) DIP switch setting Change the DIP switch as shown below. 1 2 3 Operating conditions: OFF ON ON Temporary stop Fig. 20 II. How to Connect 1) Connect a switch with OUT1 on one side and with IN1 on the other. Fig. 21.

(Part 1: General requirements) ISO 10218: Manipulating industrial robots -Safety. etc. Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.

Danger indicates a hazard with a high level of risk which, if not avoided, indicates a hazard with a level of risk which, if not avoided, level of risk which, if not avoided, will result level of risk which, if not avoided, result Danger in death or or serious injury. Warning Warning 1.

Spare Parts List 290301 Diaphragm Assy NBR 1 Part number Part name Material Quantity 29038 Diaphragm NBR 1 29063#1 Valve NBR 1 JIS B 2401, P3 O ring NBR 2 JIS B 2401, P7 O ring NBR 1 JIS B 2401, P10 O ring NBR 1 JIS B 2401, P34 O ring NBR 1 -9- #1 -9-10-10- Revision A Format change and content review B Drawing update 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249

RY0F H ol d out put pressure 1 Set dependi ng on t he dat a of RY00RY0B 0 Set pressure i m m edi at el y bef ore com m uni cat i on abnorm al i t y Set t i ng w hen f act ory i s shi pped 1 2 1 2 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON ON 7 Pressure set t i ng and out put m oni t ori ng Pressure set t i ng can be done by sendi ng i nput dat a usi

(Part 1: General requirements) ISO 10218-1992: Manipulating industrial robots -Safety. etc. Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.

(RS2H50) -1-2.(RS2H63 -1-3.(RS2H80 2025 6 - -2-1. -2-2. 7 - 2-1 ,, 3. 3-1. AF ,AR , , , ,1 ISO VG32. 5 , 5 8 - 3-2. 1 B 1 3 3-3. 3-4. 9 - () 3-5. ,, (-)90 , 5.2 Nm A 10 - 3-6. ,,, RS2H5079Nm RS2H63801214Nm -5 3-7. M4 M41.5Nm -6 11 - 4. A GR-S-010(10g) -7 5. -8-9 -8 -9 12 - , 3 6. 6-1. 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13 - / 6-2.

G SD O ccupi ed area ( I nput /out put dat a) 1 w ord / 1 w ord Low er 2 bi t s of 7 byt es of di agnosi s area are f or di agnosi s i nf orm at i on.

Air supply port (AIR SUP) 5 port solenoid valve P1 P2 Discharge port (FLUID OUT) Pump chamber A Pump chamber B Check valve Actuating chamber B Suction port (FLUID IN) Diaphragm A Diaphragm B Actuating chamber A Actuating chamber A Actuating chamber B Actuating chamber A Actuating chamber B Discharge port Discharge port Pump chamber B Pump chamber B Pump chamber A Pump chamber A Suction port

Lock keys ( ref er t o P8) M i ni m um pressure ( F_1) adj ust i ng range M axi m um pressure ( F_2) adj ust i ng range 90% 100% 120% 100% 0% 0% 10% 20% 20m A 20m A 5V 10V 20m A 20m A 5V 10V 4 0 0 0 12 10 2. 5 5 4 0 0 0 12 10 2. 5 5 ( N ot e 1) : F_1 i s adj ust abl e i n a range f rom 20% t o 90% of t he rat ed val ue. ( D EFAU LT VALU E: 0% ) ( N ot e 2) : The pressure of l ess t han 0%

Air exhaust port (AIR EXH) Air supply port (AIR SUP) Discharge port (FLUID OUT) Pump chamber A Pump chamber B Check valve Actuating chamber B Suction port (FLUID IN) Diaphragm A Diaphragm B Actuating chamber A Actuating chamber A Actuating chamber A Actuating chamber B Actuating chamber B Discharge port Discharge port Pump chamber B Pump chamber B Pump chamber A Pump chamber A Suction port

Speci f i cat i ons I TV1010 I TV1030 I TV1050 I TV2010 I TV2030 I TV2050 I TV2090 M odel I TV3010 I TV3030 I TV3050 M i ni m um suppl y pressure Set pressure + 0. 1M Pa Set pressure 13. 3kPa M axi m um suppl y pressure 0. 2M Pa 1. 0M Pa 1. 0M Pa 101kPa Set pressure range 0. 0050. 1M Pa 0. 0050. 5M Pa 0. 0050. 9M Pa 1. 380kPa Vol t age D CV Pow er source Current consum pt i on A or l ess

FGDA(1 ) FGDB(2 ) 50mm Rc Rc 9/11 FGX-OM-L007-C 5. 1 1) 50mm 2) 0.02MPa 0.02MPa 3) 2 1) 2) 6. ,0.1MPa, 11 1) 2) oC 40 3) IN OUT 4) 5) 6) 7) *2 250mm 8) 21 1) 6 1 2) 3) 2 250mm * * 4) 5) *:FGDT/F 25NmFGDC/E 15Nm 10/11 FGX-OM-L007-C 3 1) 2) 7. 1 2 1 11/11 FGX-OM-L007-C Revision history A P6. 10 1 B P5. P6.1-2. P7.