16 No.ZL3-OM00801-A 7.2 1 (/) ZL3/ZL6 ZL3-JSY3140-5LZ -a 1 3) 2) DC24V 1) 300mm 300mm * *0.150.18Nm 2) D: E: 1 1 1 1 3) 1 1 2 X12 ZL3/ZL6 SY100-30-4A-6 1 2) / 1) 2) 300 4 DC24V 6 600 10 1000 15 1500 20 2000 25 2500 30 3000 50 5000 ZL3/ZL6 SY100-30-A *x2 17 No.ZL3-OM00801-A ZL3/ZL6 ZS-39-5G ZL3-LW1-N-A 1 1) N NPN P PNP 2 ZL3/ZL6 ZL3-EJ1-H-A 1 2) 1) M 0.35 MPa
The plug connector assembly part number is “SY100-30-□A-*.” (The “□” indicates the voltage, and the “*” indicates the lead wire length.)
Check the part number list below.
Ex.) For the DC type with a 300 mm lead wire, the part number will be “SY100-30-4A,” and for the DC type with a 2000 mm lead wire, the part number will be “SY100-30-4A-20.”
The part number is as follows: SY100-30-∗. (e.g., for a 300 mm DC lead wire: SY100-30-4A)
16 6.86 14.2 Bore size Standard stroke 6 15, 30, 45, 60 10 15, 30, 45, 60 16 15, 30, 45, 60, 75, 100, 125, 150 * 6 only Spring with secondary mounting load Spring with primary mounting load * Manufacture of intermediate strokes at 1 mm intervals is possible.
3) 86.1 One-touch fitting (SUP port, EXH port) Applicable tubing O.D. : 4, 5/32" : 6, 1/4" SY50M-M1SY50MN0 00 : 8, 5/16" (73.6) 2B 4A 1 P 86.1 2B 91.6 87.8
hole M5 x 0.8 [4 (A), 2 (B) port] 9.3 27.8 17.8 20.3 20.3 4A 2B P P P 55.5 4A 2B 4A 2B 4A 2B 4A 2B 4A 2B 34 17 6 10 8.2 (Not used.) 5 2 x 5.5 (For mounting) (Pitch) P=27.5 23.5 1/8 [4 (A), 2 (B) port] (Station 1) (Station n) 1/8 [Pilot port: Lateral (-P)] 61.5 43 25 EB EA EB EA 11 M5 x 0.8 [5 (EA), 3 (EB) port] 18 (Pitch) P=27.5 Dimensions (Common to Type 30 and Type 31) n: Stations 20 11
Port size VCB2 VCW20-12-01A 34 40 25 30 12.8 12.8 5 4.5 6 13 1/8, 1/4 VCW30-12-02A 42 52 30 40 19 19 6 5.5 7 19 1/4, 3/8 VCB3 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-02A 42 52 30 40 23 23 6 5.5 7 19 1/4, 3/8 VCB4 VCW30-12-04A Note 1) 48 56 36 44 23 23 6 5.5 7 23 1/2 VCW40-12-06A 56 65 44 53 28.2 28.2 6 5.5 7 26 3/4 2 mounting screws (for mounting bracket) are included
IDF37E-30 IDF55E-30 IDF75E-30 IDU22E-30 IDU37E-30 IDU55E-30 IDU75E-30 59 40 IDF15E1-20, IDF22E-20, IDF37E-20 IDU15E1-20 IDF22E-30, IDF37E-30 IDF55E-30 IDU22E-30, IDU37E-30, IDU55E-30 30 mA 25 46 125 10 A 60 39 200 V type 60 81 148 50 36 73 133 IDF75E-30, IDU75E-30 IDF100F IDF125F IDF150F IDF190D IDF240D IDF370D 15 A 74 151 46 50 122 146 30 A 60 60 55 148 36 70 73 166 50 A IDF100F to 150F
AXT661-13AL AXT661-13AL-6 AXT661-13AL-10 AXT661-13AL-20 AXT661-13AL-30 AXT661-13ANL AXT661-13ANL-6 AXT661-13ANL-10 AXT661-13ANL-20 AXT661-13ANL-30 AXT661-14AL AXT661-14AL-6 AXT661-14AL-10 AXT661-14AL-20 AXT661-14AL-30 AXT661-14ANL AXT661-14ANL-6 AXT661-14ANL-10 AXT661-14ANL-20 AXT661-14ANL-30 Note) When using the negative common specifications, use valves for negative common. 79 Plug Lead
VJ10-20-4A-6 2 pcs. 5A 10 ZS ZP (For DC) 4A 20 VJ10 6 Lead wire length ZCU Nil 30 50 0.6 m 3 m 5 m (For 100 VAC) 1A 36 VJ10 6 AMJ (For 110 VAC) Note) If ordering switch with 5 m lead wire, specify both switch and lead wire with connector part numbers. Ordering example) ZX100-K150Z-ECN1 pc. VJ10-20-4A-6 2 pcs. ZS-10-5A-50 1 pc. 3A 36 VJ10 6 Misc.
AXT661-12AL AXT661-12AL AXT661-14AL AXT661-14ANL AXT661-13ANL AXT661-13AL 300mm 300mm AXT661-14AL-6 AXT661-14ANL-6 AXT661-13ANL-6 AXT661-13AL-6 600mm 600mm AXT661-14AL-10 AXT661-14ANL-10 AXT661-13ANL-10 AXT661-13AL-10 1000mm 1000mm AXT661-14AL-20 AXT661-14ANL-20 AXT661-13ANL-20 AXT661-13AL-20 2000mm 2000mm AXT661-14AL-30 AXT661-14ANL-30 AXT661-13ANL-30 AXT661-13AL-30 3000mm 3000mm Note) When
For size 1 VVX021S 4A 4A 4A 4A F F F SMC SMC SMC SMC For size 2 VVX022S 4A 5 x Rc1/4 (Individual port) For size 3 VVX023S 4A Enter the products part number in order, counting the 1st station from the D side (left in the manifold arrangement, when viewing the individual port in front). DimensionsPage 35 13 Series VX21/22/23 Single Unit For Water This valve can also be used with air.
connectors, so switching from the F kit (D-sub connector) to the S kit (serial transmission) can be done simply by changing the kit section. 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 6 7 8 9 10 (Refer to the connector wiring diagram.)
6 mounting hole G3 30 Approx. 12 Approx. 6 G4 15 P C Applicable wire size: 0.2 mm2 to 2.5 mm2 (AWG 24 to 12) Tightening torque: 0.5 to 0.6 [Nm] 5 156 168 144 12 Mounting screw Screw size: M5 Tightening torque: 3.24 [Nm] TE1 Mass: 0.5 [kg] 6 1.6 6 99 Approx. 20 119 11 13 11.
Maximum stations are 18. 18 6 19 7 20 8 21 9 22 10 23 11 24 1.
9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A Station 2 Station 3 Station 4 Station 5 10A COM 10B Station 6 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B Station 7 Station 8 If alignment is not specified, the internal wiring will be double wiring (connected to SOL. a and SOL. b) regardless
F-4300-2 F-4300-5 F-4300-15 F-4300-30 F-4300-60 F-4300-100 .2 .5 .5 .5 .5 1 2 5 15 30 60 100 30 30 45 60 120 120 .1 .2 .4 .6 1.5 2.0 .2 .35 .6 1.0 2.5 3.5 3A 4A 4A 4A 4A 4A Wetted materials For special deadband or current requirements, contact factory See Appendix A F-4300BARBED FITTING SPECIAL OPTIONS RANGE (PSI) MOUNTING STYLE B80 = NYLON 1/16" ID B85 = NYLON 1/8" ID P80 = POLYSULFONE 1
How to Order Connector Assembly 80 A DXT170 Lead wire color Lead wire length Lead wire with socket Lead wire length L (mm) Symbol Note Symbol Nil 6 10 15 20 25 30 Nil Socket only (2 pcs.)
, so switching from the F kit (D-sub connector) to the S kit (serial transmission) can be done simply by changing the kit section. 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 6 7 8 9 10 (Refer to the connector wiring diagram.)