Model: SV2000, Wiring: Double, Fitting: With One-touch Fitting for 5/32 in
Refer to back page 50 for Safety Instructions and pages 3 to 9 for 3/4/5 Port Solenoid Valve Precautions.
With(Wihtout light) Note) Standard lead wire length: 300mm Coil voltage 1 2 3 4 5 6 9 100VAC(50/60Hz) 200VAC(50/60Hz) 110VAC(50/60Hz) 220VAC(50/60Hz) 24VDC 12VDC Others 23 Series VQZ 3 Port Solenoid Valve Manifold Options Manifold Options Blank plate VVQZ100-10A-2 VVQZ200-10A-2 VVQZ300-10A-2 Used to reserve a valve mounting space on the manifold for future use.
Note) 2 position single 1 2 Note) 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC G: Grommet C kit single only.
OUT1: Green, OUT2: Red IP40 Operating/Stored: 35 to 85% RH (No condensation) 1000 VAC for 1 minute between live parts and enclosure 50 M or more between live parts and enclosure (at 500 VDC mega) 2% F.S.
SX5000-50-1AC4 C6 C8 SX3000-50-1A-C4 C6 1 Manifold block assembly P, R ports SY3000 8 One-touch fitting P, R ports SY5000 10 One-touch fitting 2 SUP/EXH block assembly SX5000-51-1A SX3000-51-1A 3 End block assembly R For D side SX5000-52-1A SX3000-52-1A 4 End block assembly L SX3000-53-1A SX5000-53-1A For U side 5 Connector box VZ3000-106-1A 24VDC only 6 Rail stopper Made by Kasuga Electronic
SX5000-50-1A-Q C4 C6 C8 SX3000-50-1A-Q C4 C6 1 Manifold block assembly P, R ports SY3000 8 One-touch fitting P, R ports SY5000 10 One-touch fitting 2 SUP/EXH block assembly SX3000-51-1A SX5000-51-1A 3 For D side End block assembly R SX3000-52-1A-Q SX5000-52-1A-Q 4 End block assembly L SX3000-53-1A-Q SX5000-53-1A-Q For U side 5 Connector box VZ3000-106-1A 24VDC only 6 Rail stopper Made by
assembly DXT031-38-1A Applicable individual EXH spacer assembly DXT155-17-1A Stations VV5F3 05 40 2 02 R port 02 2 stations P port 20 20 stations A, B port 3-4-25 26 Series VF3000 B Mount (Integrated type) Applicable solenoid valve Bottom ported/Individual EXH type Type 50 VV5F3 05 50 4 02 VF350Applicable blanking plate assembly DXT031-38-1A EXH (R) port (Valve body) Stations 02 2 stations
Coil voltage Configuration Note 2) VQ1000 VQ2000 1 2 3 4 5 6 VQ0 100V AC (50/60Hz) 2 position single 1 2 3 4 5 200V AC (50/60Hz) 2 position double (latching) 110V AC (50/60Hz) Electrical entry (2) (1) 3 position closed center 220V AC (50/60Hz) 24V DC 12V DC Grommet (Except for double (latching) and AC.)
denotes the bottom ported type. 3-6-12 13 Explosion Proof Solenoid Valve Series 50-VFE/50-VPE Specifications: 50-VFE3000/5000 Explosion proof solenoid valve 5 port/50-VFE3000, 5000 3 port/50-VPE500, 700 VK 50-VFE3000 50-VFE5000 Series VZ Fluid Air Quality of explosion proof spec.
, 400, 415 VAC (50 Hz) 380 to 420 VAC (60 Hz) 420, 440, 480 VAC (50 Hz) 420 to 520 VAC (60 Hz) 220 VAC (50 Hz) 220 to 240 VAC (60 Hz) 380, 400, 415 VAC (50 Hz) 380 to 400, 400 to 415, 415 to 440 VAC (60 Hz) 440, 460 VAC (50 Hz) 440 to 460, 460 to 500 VAC (60 Hz) Outlet voltage Symbol 500 1 500 VA 100 VAC (50 Hz) 100, 110 VAC (60 Hz) 1000 2 1 kVA Singlephase 2000 2 kVA 3 4 9 200 VAC (50 Hz
AL-196H 04 06 08 10 12 16 20 24 28 32 04 06 08 10 12 16 20 24 28 32 JIS B2401-1A-G70 JIS B2401-1A-G35 AL-197H JIS B2401-1A-G90 JIS B2401-1A-G45 JIS B2401-1A-G50 JIS B2401-1A-G105 JIS B2401-1A-G55 AL-198H JIS B2401-1A-G65 Petroleum, Emulsion, Water-glycol FHIA N W JIS B2401-1A-G125 JIS B2401-1A-G70 AL-199H JIS B2401-1A-G80 JIS B2401-1A-G145 JIS B2401-1A-G95 AL-200H JIS B2401-1A-G100 JIS B2401
Bore size Series CJ2 Pressure 0.5 MPa Load ratio 50% Stroke 60 mm Series CS1 Pressure 0.5 MPa Load ratio 50% Stroke 1000 mm Series MB, CA Pressure 0.5 MPa Load ratio 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load ratio 50% Stroke 300 mm Average speed (mm/s) Series 6 10 16 125 140 160 180 200 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Vertically upward Horizontal VQC1000
(Valve) SYJ5000-21-1A 1 pc. (Blank plate ass'y) PSS5YJ5-43-03-C4 1 pc. (Manifold base) SYJ5140-5LZ 1 pc. (Valve) SYJ5240-5LZ 1 pc. (Valve) SYJ5000-21-1A 1 pc.
/60 Hz 200 VAC, 50/60 Hz 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 6 24 VDC 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option Body Option Pilot type 0 1 Standard Direct manual override R Internal pilot External pilot Nil Option How to Order Pilot Valve Assembly Option SF4 F 1 22 Coil rated voltage 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC
/60 Hz 200 VAC, 50/60 Hz 110 to 120 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz 9 Other VFS VFR 4 5 6 VQ7 7 Option Body Option Pilot type 0 1 Standard Direct manual override Nil R Internal pilot External pilot Option Option How to Order Pilot Valve Assembly SF4 F 1 22 Coil rated voltage 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50
1A 1.9 180 50 or less 0.95 (0.43) center % 2.0 Pressure NVFR3500 NYFR3510 If. 2.2 180 50 or less 0.95 (0.43) center % 2.3 i!
block assembly (for RS): SX3000-51-5A 2 pcs 1 location EXH block disk: SX3000-77-1A SUP/EXH block assembly (Standard): SX3000-51-1A The following columns shall be filled in by SMC.
100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option 3-5-94 95 5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR6000 Cylinder Speed Chart Use as a guide for selection.
(W) [Current mA] DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Note) Inrush Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Refer to pages 3-3-24 to 3-3-27 for manifold use.