A A1 MM U1 L1 RR1 A1 L1 E1 MM RR1 U1 0.4 0.2 + 0.2 + 0 0.2 0.4 0.2 0.4 10 12 16 20 +0.002 0 5 6.4 8 10 0.2 0.4 0.1 0.3 0.2 0.4 0.2 0.4 +0.002 0 5 6.5 8 10 #8-32UNC 10 12 16 20 12 16 20 25 10 12 16 20 14.6 16.6 21 25.6 RCS-01 RCS-015 RCS-02 RCS-025 RCD-01 RCD-015 RCD-02 RCD-025 21.5 32 34 41 6 6 6 8 16 25 25 30 #8-32UNC #8-32UNC #10-32UNF 1/4-28UNF 6.3 12 10.3 18 7 14 11.5 14
1 station Rc Q CE-compliant Nil CE-compliant F N T G 20 20 stations NPT NPTF A port: M5 x 0.8 B port: M5 x 0.8 Note) Applicable only for DIN terminal type How to Order Type 41: Base mounted (A, B port side ported) Applicable solenoid valve VK3140-(-Q) VK334-(-Q) Type VK3140 VV5K3 M5 05 41 Type VK334 Solenoid direction Valve stations Applicable blanking plate assembly VK3000-7-1A 01 1 station
COIL NO. 6 7.8 8.5 12 14 5.4 7 7.7 11 13 3 3.8 4.4 6 7 5C-103-A24 5C-104-A24 5C-105-A24 5C-106-A24 5C-107-A24 5C-3-K24 5C-4-K24 5C-5-K24 5C-6-K24 5C-7-K24 18.5 24 32 39 45 17 22 29 35 41 9 12 16 20 23 5C-108-A24 5C-109-A24 5C-110A24 5C-111-A24 5C-112-A24 5C-8-K24 5C-9-K24 5C-10-K24 5C-11-K24 5C-12-K24 48 54 94 120 153 43 48 85 110 138 24 28 47 60 76 5C-113-A24 5C-114-A24 5C-115-A24 5C-116
VK300-82-2-01 VK300-82-2-03 110 VAC 110V 200 VAC 200V VK300-82-2-02 VK300-82-2-04 220 VAC 220V VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD 3-2-11
Terminal no.12 Switch Terminal no. 12 11 Recommended accessory cable dia. is 0.14 to 1.5mm2 9 10 Terminal no.1 Fig. 3-7 Wiring of contact for remote signal inputsExample 3.3 Installation HRS Series 3-12 HRX-OM-M090 Chapter 3 Transport and Setting Up 3. Plug the prepared connector in to the contact input/output connector that is on the back of the thermo-chiller.
Model AS1ll1FS-M5l AS2ll1FS-01 AS2ll1FS-02 AS3ll1FS AS4ll1FS Metric size 2 3.2 4 6 3.2 4 6 8 10 3.2 4 6 8 10 6 8 10 12 10 12 16 Tubing O.D.
Model AS1ll1FSGl-M5 AS2ll1FSGl-01 AS2ll1FSGl-02 AS3ll1FSGl AS4ll1FSGl Metric size 2 3.2 4 6 3.2 4 6 8 10 3.2 4 6 8 10 6 8 10 12 10 12 16 Tubing O.D.
Terminal no.12 Switch Terminal no. 12 11 Recommended accessory cable dia. is 0.14 to 1.5mm2 9 10 Terminal no.1 Fig. 3-8 Wiring of contact for remote signal inputsExample 3.3 Installation HRS Series 3-12 HRX-OM-R005 Chapter 3 Transport and Setting Up 3. Plug the prepared connector in to the contact input/output connector that is on the back of the thermo-chiller.
Terminal no.12 Switch Terminal no. 12 11 Recommended accessory cable dia. is 0.14 to 1.5mm2 9 10 Terminal no.1 Fig. 3-7 Wiring of contact for remote signal inputsExample 3.3 Installation HRS Series 3-12 HRX-OM-R016 Chapter 3 Transport and Setting Up 3. Plug the prepared connector in to the contact input/output connector that is on the back of the thermo-chiller.
Centigrade(oC) Fahrenheit(oF) 5.13 12 Changing pressure unit Pressure unit can be changed.
Centigrade(oC) Fahrenheit(oF) 5.13 12 Changing pressure unit Pressure unit can be changed.
Setting of the selected alarm Setting range: AL.01 to AL.51 to 63. Press the [MENU] key once. Returns to the main display (which shows the circulating fluid temperature).
C 1. ##0016 ## 00 01 1 02 2 03 3 04 4 05 5 06 6 07 7 08 8 09 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 2. **No. 3.
X A 2 10 24 1 P 3 R Manual override 34 41 3.5 (Lead wire length) 38.5 300 Cover diameter 1.4 Cross sectional area 0.2mm2 SMC 35.5 A port PE 16 12 7.5 7.5 14.5 7 7.5 1/8 NPTF P,A,R port M5 x 0.8 PE port L type plug connector (L): VQZ115(R)L -01T M type plug connector (M): VQZ115(R)M -01T 51.5 300 (Lead wire length) 60.5 300 (Lead wire length) Cover diameter 1.5 Cross sectional area 0.23mm2
Setting range: MT.01 to MT.05 (Initial value: MT.01) Contact output signal 3 Select function 21. Press the [] key. Displays screen for setting the function of the Contact output signal 3.
Choose Manitold Block desired. e.g. #12, #14 or #16. 4. To specily a valve mounted on a manilotd btock Insd manitold number into valve number i.e. NVSA 41 1 4-'l 1 N b a NVSA 41 1 4-0ON vatle mount , on a #11 block. 't1 '12 = Mouoled on siacking manilotd block r,, NPT side ports (2) '14 = Mounled on stacking manifold block 7."
For 20A/20B 25 5 1.5 4 x 2.6 Depth 7 or less Atmospheric vent port 30 20 30 20 Lead wire with connector M5 x 0.8 Thread depth 3.5 01 4 x 2.6 Depth 7 or less Atmospheric vent port 15.2 R1/8 7.2 N01 NPT1/8 A Piping specification Port size A 01 R1/8 Width across flats 10 N01 NPT1/8 Width across flats 12 20 ZSE20(F)/ISE20 Series Dimensions With bracket ZSE20(F) ISE20 Option 2 30 A1 25 20 Bracket
Valve model Port size VCW2 VCW20-12-01 1/8, 1/4 34 40 25 30 12.8 12.8 5 4.5 6 13 VCW30-12-02 1/4, 3/8 42 52 30 40 19 19 6 5.5 7 19 VCW3 VCW30-12-04 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-02 1/4, 3/8 42 52 30 40 23 23 6 5.5 7 19 VCW30-12-04 VCW4 1/2 48 56 36 44 23 23 6 5.5 7 23 VCW40-12-06 3/4 56 65 44 53 28.2 28.2 6 5.5 7 26 Bracket material: Stainless steel 3 Series VCW Dimensions (N.C
VK300-82-2-01 VK300-82-2-03 110 VAC 110V VK300-82-2-02 200 VAC 200V VK300-82-2-04 220 VAC 220V 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 DIN terminal type Indicator light (Built-in connector) Marking Circuit with indicator light AC circuit diagram 12 VDC or less circuit diagram 24 VDC or more circuit diagram