D C B E1 L1 MM H A A1 R1 U1 d NDH10 NX 40 50, 63 80 100 I-04 I-05 I-08 I-10 NT-04 NT-05 NT-08 NT-10 21 25.4 22 8 69 22 24 55 M14 X 1.5 15.5 20 M14 X 1.5 12 16 +0.070 0 0.1 0.3 26 31.2 27 11 74 27 28 60 M18 X 1.5 15.5 20 M18 X 1.5 12 16 +0.070 0 0.1 0.3 31 37.0 32 13 91 37 36 71 M22 X 1.5 22.5 26 M22 X 1.5 18 28 +0.070 0 0.1 0.3 39 47.3 41 16 37 40 83 M26 X 1.5 24.5 28 M26 X 1.5 105 20 30
Part No. 40 50, 63 80 100 D H B C A A1 E1 L1 MM R1 U1 d NDH10 NX 40 50, 63 80 100 I-04 I-05 I-08 I-10 NT-04 NT-05 NT-08 NT-10 +0.070 0 0.1 0.3 25.4 21 69 22 24 55 M14 X 1.5 15.5 20 M14 X 1.5 8 22 12 16 +0.070 0 0.1 0.3 74 M18 X 1.5 11 27 31.2 26 27 28 60 M18 X 1.5 15.5 20 12 16 +0.070 0 0.1 0.3 32 37.0 31 91 37 36 71 M22 X 1.5 22.5 26 M22 X 1.5 13 18 28 +0.084 0 0.1 0.3 39 16 41 47.3 105
Round head screw (M3 x 8), 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6), 2 pcs. Round head screw (M3 x 8), 4 pcs. (2)End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20), 1 pc. P tight screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4x20) with washer, 1 pc.
Applicable bore size (mm) d H1 B1 C D NT-02 20 M8 x 1.25 5 13 (15) 12.5 NT-03 25, 32 M10 x 1.25 6 17 (19.6) 16.5 NT-G04 40 M14 x 1.5 8 19 (21.9) 18 NT-05 50, 63 M18 x 1.5 11 27 (31.2) 26 NT-08 80 M22 x 1.5 13 32 (37.0) 31 NT-10 100 M26 x 1.5 16 41 (47.3) 39 D-X Technical Data 309 Air Cylinder: Standard Type Double Acting, Double Rod CG1W Series 20, 25, 32, 40, 50, 63, 80, 100 How to Order
Mounting dimension on side face Size Bolt Tap depth Size Bolt 05 M4X0.7 5 Body tap Body through hole 1 M5X0.8 6 05 M4X0.7 M3 1 M5X0.8 M4 Piping Fig. (4) and Table (8) show port position and size. A port A port B port B port Side port Front port Fig.4 Port position 24 - Table 8. Port size .
Size B d d C l 0.040 0.076 0.040 0.076 0.040 0.076 0.050 0.093 8 10 10 14 M10 X 1.25 19.6 21.9 25.4 31.2 16.5 18 21 26 25 32 40 50, 63 6 7 8 11 23 27 31 38 25 32 40 50, 63 17 19 22 27 7.6 9.6 9.6 13.4 18.2 22.2 26.2 32.2 CD-MU02 CD-MU03 CD-MU04 CD-MU05 NT-03 NT-MU03 NT-04 NT-05 M12 X 1.25 M14 X 1.5 M18 X 1.5 A nut is attached with rod end male thread as standard.
For DIN rail part no., refer to page 31. Note 2) When two or more symbols are specified, indicate them alphabetically.
Mount the sensor head using two M3 screws (not supplied with the product). Do not pull the cable connected to the sensor head. Pulling the cable with excessive force may cause sensor head breakage or wire breakage. 2) Installation of sensor amplifier Mount the sensor amplifier using two M3 screws (not supplied with the product). Do not pull the cable connected to the sensor amplifier.
31 31 31 B 104 124 149 174 199 MXW12 6 W 31 11 11 11 11 V 124 144 169 194 219 W V A 59.5 34.5 34.5 34.5 34.5 34.5 B 135.5 160.5 185.5 210.5 235.5 260.5 MXW16 8.5 W 39.5 14.5 14.5 14.5 14.5 14.5 V 155.5 180.5 205.5 230.5 225.5 280.5 A 68.5 43.5 43.5 43.5 43.5 43.5 43.5 B 168.5 193.5 218.5 243.5 268.5 293.5 318.5 MXW20 10 W 48.5 23.5 23.5 23.5 23.5 23.5 23.5 V 188.5 213.5
31 Series MGG Dimensions Front mounting flange style: MGGF 20 to 50 M N HR HN (MAX.)
Set each P1/P2 (set value), referring to the Accumulated output mode on page 31.
Air consumption (per unit) 0.058 m3/min (ANR) 0.085 m3/min (ANR) J (= Unit of conversion of A) Air consumption (for total operation) 6,525 m3/year 95,625 m3/year K = J x 60 x I Power consumption 2 0.19 kW 0.27 kW L (Theoretical value obtained from A and B) Power consumption cost per year 5,344 yen/year 75,938 yen/year M = C x I x L 1 Adsorption time is the time in a cycle when the ejector
Round head screw (M3 x 8), 4 pcs. EX600-ZMV2 (Specified for SY series) Enclosed parts: Round head screw (M4 x 6), 2 pcs. Round head screw (M3 x 8), 4 pcs. (2)End plate bracket EX600-ZMA2 Enclosed parts: Round head screw (M4 x 20), 1 pc. P tight screw (4 x 14), 2 pcs. EX600-ZMA3 (Specified for SY series) Enclosed parts: Round head screw (M4 x 20) with washer, 1 pc.
Panel cutout dimensions ITVX 28 SMC PVQ K P C U O S H L VY1 23 28 VBA VBAT Plate thickness: Max. 2.1 22 AP100 26 (Max. 28) 42 Through hole for M3 3.2 59.5 73.5 SMC 2 10.5 35 OUT IN 12 743 ARM10 Series Dimensions Panel cutout dimensions ARM10F1-06 08 28 4 x R1 or less 28 to 28.5 IN OUT 37 58 34 23 20 Plate thickness: Max. 2.1 22 5 15 34 14 31 SMC 62 Through hole for M3 3.2 SMC K P U C S O
Bracket Mounting Procedure
BA-06 BA-08 BA-10 D-B7/B80 D-B73C/B80C D-G79/K79 D-K79C BM1-01 BM1-02 BM1-32 BM1-04 BM1-05 BM1-06 Note) Two kinds of auto switch mounting brackets are used as a set.
Calle 18 69-05 Apart.
Function selection mode 31 Default setting 31 F 0 Differential pressure check mode, pressure range, display unit 33 F 1 Setting of OUT1 39 F 2 Setting of OUT2 42 F 3 Digital filter setting 44 F 4 Auto-preset function 45 F 6 Fine adjustment of display value 47 F10 Sub display setting 48 F11 Display resolution setting 54 F14 Zero cut-off setting 55 F80 Power saving mode 56 F81 Security code
B A 24.6 A B 38 48 14 12 5 3 1 B A 30 45 14 3 5 1 12 2-5.6 Mounting hole Manual override 2-5.6 Mounting hole 45 30 Manual override 14.5 27 30.5 32 41.5 91.5 129 79 PE X PE X 32 41.5 30.5 27 R1 R2 P R2 R1 14.5 P 19.5 19.5 (21) (21) Rc 1/8 External pilot port Rc 1/8 PE port Rc 1/8 PE port 19.5 (21) 19.5 (21) 31 31 5-Rc 1/4, 3/8 1(P), 4(A), 2(B), 5(R1), 3(R2) port 31 31 5-Rc 1/4, 3/8 1(P),
Part number Description Note ZS-40-A Lead wire with M8 connector Length: 3 m ZS-42-A Bracket With mounting screws for PFMC7501/7102 (M3 x 5, 2 pcs.) ZS-42-B Bracket With mounting screws for PFMC7202 (M3 x 5, 2 pcs.)