SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-31-03-M3"

Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 URL http://www.smcworld.com 2009 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 1st printing LY printing NX 12200SZ Printed in Japan.

Air consumption (per unit) 0.058 m3/min (ANR) 0.085 m3/min (ANR) J (= Unit of conversion of A) Air consumption (for total operation) 6,525 m3/year 95,625 m3/year K = J x 60 x I Power consumption 2 0.19 kW 0.27 kW L (Theoretical value obtained from A and B) Power consumption cost per year 5,344 yen/year 75,938 yen/year M = C x I x L 1 Adsorption time is the time in a cycle when the ejector

(Fixed SI unit [(l/min, or l, m3 or m3 x 103)] will be set for switch type without the unit switching function.) Note 3) The high flow rate type is CE marked; however, the linearity with applied noise is 5% F.S. or less. Note 4) Switch output and accumulated pulse output selections are made using the button controls.

Av = Q (8) P Av : Flow coefficient [m2] Q : Flow rate [m3/s] P : Pressure difference [Pa] : Fluid density [kg/m3] (3) Formula of flow rate It is described by the practical units. Also, the flow-rate characteristics are shown in Graph (2).

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com YA 03 YA-03 YA-05 10 12 6.5 6.5 42 50 6 8 16 20 6.8 9 18 20 Applicable air cylinder bore Bore size (mm) 32, 40 50, 63 W V U Weight (g) Part No. 03 05 32, 40 50, 63 Mounting bracket YA-03 YA-05 55 100 56 67 18 22 6 8

Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105 JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan. 1st printing April, 1998 D-SMC.L.A. P-67.5 (YG)

Av = Q (8) P Av : Flow coefficient [m2] Q : Flow rate [m3/s] P : Pressure difference [Pa] : Fluid density [kg/m3] (3) Formula of flow rate It is described by the practical units. Also, the flow-rate characteristics are shown in Graph (2).

Av = Q .(8) $P Av : Flow coefficient [m2] Q : Flow rate [m3/s] $P : Pressure differential [Pa] : Fluid density [kg/m3] (3) Formula for flow rate Described by the practical units. Also, the flow-rate characteristics are shown in Graph (2).

Drain guide 1/4 Note 4) AFM30, 40 Rc NPT G Nil C AFM20 to 40 1/8 1/4 3/8 1/2 3/4 01 02 03 04 06 R Flow direction: Right to left AFM20 to 40 N Note 1) Float type auto drain (N.O.)

A leakage current breaker having Ig of 15[mA] is used with the NV-SP/SW/CP/CW/HW series. 11 31 11. OPTIONS AND AUXILIARY EQUIPMENT 11.9 EMC filter (recommended) For compliance with the EMC directive of the EN Standard, it is recommended to use the following filter.

Note 1) Sampling air flow rate: Number of particles contained in 75l of air Note 2) Actuator: 1 million cycles Solenoid valve: 2 million cycles Particle generation characteristics of CM2 Particle generation characteristics of CXSL Particle generation characteristics of CY1B 106 106 106 Particle concentration (particles/m3) Particle concentration (particles/m3) Particle concentration (particles

Note 1) Sampling air flow rate: Number of particles contained in 75l of air Note 2) Actuator: 1 million cycles Solenoid valve: 2 million cycles Particle generation characteristics of CM2 Particle generation characteristics of CXSL Particle generation characteristics of CY1B 106 106 106 Particle concentration (particles/m3) Particle concentration (particles/m3) Particle concentration (particles

(VY1A01 only) M5 external pilot port Foot (Option) Port 1 (P), 2 (A), 3 (R) 3 x M5 VEXA-18-3A Hexagon socket head cap screw M3 L = 8 (2 pcs.) (With spring washer) ( ) 2 x 4.5 Mounting hole VEXA-18-2A Bracket (Option) Hexagon socket head cap screw M3 L = 8 (2 pcs.)

x 0.5 thread depth 3.5 10 9 + Stroke 2.7 8 6.7 2-M3 x 0.5 thread depth 3.5 (Piping port) 20 20.5 5.5 Stroke 42 + Stroke 5.5 4.5 13.4 32 + Stroke 5 + Stroke 12 2.75 11 1.2 M3 x 0.5 x 3 L (Hexagon socket head set screw) M8 x 1.25 x 7.5 L (Bolt holder) 0.5 25 0.2 25 0.2 5.3 5.3 16 32 31 2-M3 x 0.5 through 3.4 through 6.5 counterbore with depth 5 (Opposite side: Same) 5.5 2-M3 x 0.5 through

Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2002 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.

Pass the auto switch mounting screw (M3) supplied with the auto switch mounting band from the through-hole side of the auto switch mounting band and engage it with the M3 female thread of the auto switch mounting band through the through-hole in the switch bracket. 5. Tighten the auto switch mounting screw with the specified tightening torque (0.6 to 0.7 Nm). 6.

VXE2320-03 VXE2230-03 VXE2330-03 VXE2240-03 VXE2340-03 VXE2250-03 VXE2350-03 VXE2260-03 VXE2360-03 VXE2260-04 VXE2360-04 Non-leak/ Medium vacuum 106 Pam3/sec or less Note) 1/8 (6A) Air 300 NBR, FKM 1 cm3/min or less Note) Value for V and M options (Non-leak/Medium vacuum) 470 620 300 470 620 470 620 560 700 560 700 470 620 470 620 470 620 560 700 560 700 560 700 3 0.45 0.33 3.0 4.5 2.3 0.46

It may not be possible to connect the tubing, or leakage or disconnection may occur after connection. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2000 SMC CORPORATION All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.

VBA VBAT AP100 841 Series ITV009 Dimensions Manifold 27.5 40 40 27.5 4 x M3 x 0.5 thread depth 3.5 Mounting hole 11 11 25 L1 L2 Port Location z x c 8 No.

G 28 58 5H9 +0.030 0 depth 5 (5.5) 10 D-M4 x 0.7 (for work piece mounting) 10.5 12 2-M3 thread depth 5 (3.5) 6 4-8 50 18.5 10 20 17.5 22 25 35 (5) 62 72 12 (15) (6) 8 1 0.2 31 5H9 +0.030 0 depth 5 Photo micro sensor wire (300mm) 10 13 1.5 [5.5] 6 25 (4) 30.5 10 (39.5) E Motor wire (300mm) Stroke + 135 The dimension inside [ ] shows the location at which the home position switch operates