(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) Note 2) This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32).

Solenoid Coil Specifications Note) The values are for an ambient temperature of 20C and at the rated voltage.

Note AXT100-DS25-015 AXT100-DS25-030 AXT100-DS25-050 1.5 m 3 m 5 m Conductor resistance /km, 20C 65 or less Cable 25 cores x 24AWG Withstand pressure V, 1 min, AC 1000 For other commercial connectors, use a 25 pins type with female connector conforming to MIL-C-24308. Insulation resistance Mkm, 20C 5 or less Note) The minimum bending radius for D-sub connector cables is 20 mm.

Burst pressure Burst pressure (MPa) Note) Min. bending radius (mm) 24 20C to 60C Operating temperature Material Nylon 12 Note) The value at temp. of 20C and with O.D. variable rate 10% max.

Membrane Dyer Series IDG Standard specifications/Single style (standard dew point 20C (4F)) Model Standard dew point 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters Range of operating conditions Standard performance conditions Inlet air pressure MPa (psi) 0.3 to 0.85 (43 to 123) 0.3 to 1.0 (43 to 145) Inlet air temperature C (F) Note

Membrane Dyer Series IDG Standard specifications/Single style (standard dew point 20C) Model Standard dew point 20C IDG5 IDG10 IDG20 IDG30 IDG50 Fluid Compressed air Macromolecular membrane dryers that act like filters Range of operating conditions Standard performance conditions Inlet air pressure MPa 0.3 to 0.85 0.3 to 1.0 Inlet air temperature C Note 1) 5 to 55 Ambient temperature C 5

Response Time Note) Based on JISB8375-1981 dynamic performance test (with coil temperature of 20C and at rated voltage).

Residence time of water at 20C is 5.5 x 10-6sec, whereas at 150C is 2.8 x 10-8 sec, or 200 times shorter.

Real-time switch output Hysteresis mode ON Flow rate conversion YES OFF P-1 P-2 Normal condition {0C, 101.3 kPa, Dry air} or standard condition (ANR) {20C, 101.3 kPa, 65% RH} can be selected.

Specifications Cleanliness class (ISO class) Class 3 Note 1) KPQ Series Brass (electroless nickel plated) Release button: Light gray Fluid Air Maximum operating pressure (20C) 1 MPa Note 2) Operating vacuum pressure 100 kPa Proof pressure (20C) 3 MPa 5C to 60C Ambient and fluid temperature Threads JIS B0203 (Taper thread for piping) Oil Fluorine-based grease Note 1) Refer to particle generation

TL TIL TLM TILM TD TID TH TIH 913 LQ3 Series Specifications Model Feature LQ310 LQ320 LQ330 LQ340 LQ350 LQ360 LQ370 Material New PFA Maximum operating pressure (at 20C) 1.0 MPa Refer to the withstand pressure and heat resistance performance data.

LLB Note 1) ANR indicates the flow rate converted to the value at 20C under the atmospheric pressure and the state of relative humidity 65%. Note 2) The accessories should be mounted by user.

0.27 0.29 0.47 (kg) AMG Float type (Normally open) Auto drain Port size Rc 3/8 Rc 1/2 Rc 3/4 Rc 1 AFF Hexagon nipple Accessory Symbol Weight 18 22 23 27 28 46 (kg) AM Body panel: White 1 Base: Gray 2 Coating color Refrigerated air dryer AMD EC Directive (with CE marking) Compliant standards Auto drain Note 1) Air flow capacity under the standard condition (ANR) [atmospheric pressure at 20C

(Coil temperature: 20C, at rated voltage, without surge voltage suppressor) Note 2) Impact resistance: No malfunction occurred when it was tested in the axial direction and at right angles to the main valve and armature in both energized and de-energized states once for each condition.

Note Conductor resistance /km, 20C 65 or less 1.5 m 3 m 5 m AXT100-DS25-015 Cable 25 cores x 24AWG AXT100-DS25-030 Withstand limit VAC, 1 minute 1000 AXT100-DS25-050 For other commercial connectors, use a 25 pin type with female connector conforming to MIL-C24308. Insulation resistance Mkm, 20C 5 or less Note) The minimum bending radius of the D-sub connector cable is 20 mm.

(Coil temperature: 20C, at rated voltage) 10-SY3000 10-SY7000 With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa) With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa) Actuation type Without light/surge voltage suppressor 12 or less Actuation type Without light/surge voltage suppressor 31 or less Type R, U Type S, Z 12 or less

(Coil temperature: 20C, at rated voltage, without surge voltage suppressor.) Note 2) Impact resistance: No malfunction occurred when it was tested in the axial direction and at right angles to the main valve and armature in both energized and de-energized states once for each condition.

The resistance of the solenoid valve is R 20 + 278 3% Ohm at 68F (20C). Do not bend or pull cables repeatedly. T4 Maximum surface temperature 275F (135C) Temperature class Hazardous Locations Specifications Terminal type (TT) L-type plug connector (L) LL-type plug connector (LL) Warning Electrical entry Note) 1.

Maximum Flow Capacity of the Compressor Intake Condition under Rated Conditions Model AFF70D AFF80D AFF90D Maximum flow capacity/Compressor intake condition*2 [m3/min] 7.3 11.5 15.1 *1 Flow at 20C, atmospheric pressure, and 65% of relative humidity *2 32C, flow rate when converted to atmospheric pressure *3 Filtration efficiency for the conditions below in addition to the rated conditions

Burst pressure Note) Min. bending radius (mm) 24 Burst pressure (MPa) Operating temperature Material 20C to 60C Nylon 12 Note) The value at temp. of 20C and with O.D. variable rate 10% max.