SMC Corporation of America
Elite Part Number Search
Search Results "S070B-VDC-M3"

D-P5DWL Auto switch model Applicable load 24 VDC relay, PLC Load voltage 24 VDC (20 to 28 VDC) Load current 6 to 40 mA or less Internal voltage drop 5 V or less Leakage current 1 mA or less at 24 VDC Operating time 40 ms or less Operating positionRed LED lights when ON. Optimum operating positionGreen LED lights when ON.

Please download it via our website, http://www.smcworld.com 16 Series HRS100/150 Standard Type Communication Function Contact Input/Output Item Specications Connector type M3 terminal block Insulation method Photocoupler Rated input voltage 24 VDC Operating voltage range 21.6 to 26.4 VDC Rated input current 5 mA TYP Input impedance 4.7 k Input signal Rated load voltage 48 VAC or less/30 VDC

3 x 7.2 (= 21.6) 8-M3 OUT2 NC Sensor 36 +0.5 0 8 Load 6.4 4 OUT1 Black 7 3 Load 1 2 3 4 Brown + 6 2 +0.5 0 Blue 19.4 5 1 12 to 24 VDC Series PF2D5 5 6 7 8 PF2D301-A(-M) Do not connect the white wire of the sensor to c of the display unit.

Proper use of the seal cap enables the enclosure to achieve IP67 specification. 25 EX## OMS1015-A Specification Specifications Model EX600-ED2EX600-ED3Power connector M12 (5 pin) Plug 7/8 inch (5 pin) Plug specifications Power Power supply (Control and input) 24 VDC, 10%, Class2, 2 A 24 VDC, 10%, 8 A Power supply (Output) 24 VDC, +10/-5%, Class2, 2 A 24 VDC, +10/-5%, 8 A Enclosure IP67 (With

35mm )2020 , M3 0.610.63 Nm , -7- , , , , ! ! 24 24 24 24VDC VDC VDC VDC Class Class Class Class2 2 2 2 UL UL UL UL Listing Listing Listing Listing ( ( ( ( ) ) ) ) D D D D ( ( ( ( ) ) ) ) ! 0~55 -8- NOx 0.1ppm a.0~55 b.35~65%RH c. d. e. f. g. h. i.() j. k. l. m. n. (IDF )(AF/AFF )(AFM/AM , -9- 4 4 4 4-2. 2. 2. 2. 4-2-1. D D 4-2-2.

DC EZ, TZ, DZ, YZ (100 VDC or more) EZ, TZ, DZ, YZ (100 VDC or more) Z EZ, TZ, DZ, YZ (24 VDC or less) Note) W/ surge voltage suppressor is available only for grommet type. 4-8-3 4 Series VP300/500/700 Precautions Be sure to read before handling. For Safety Instructions and Solenoid Valve Precautions, refer to page 4-18-2. Caution Change of Actuation Caution How to Use DIN Terminal 1.

Electrical entry Grommet Power supply voltage 12 to 24 VDC Current consumption 40 mA or less Output specification NPN open collector 2 outputs PNP open collector 2 outputs Load voltage 28 VDC or less Impact resistance 980 m/s2 Insulation resistance 50 M or more (500 VDC measured via megohmmeter) between lead wire and case Withstand voltage 1000 VAC for 1 minute (between lead wire and case

Incremental type 14.5 mT 10.8 to 13.2 VDC (Ripple less than 1%) 40 mA 0.1 mm/pulse 0.2 mm Note) (at 20C) NPN open collector (35 VDC, 80 mA) A/B phase difference output 500 VDC, 50 M or more (between case and 12E) 33.3 Hz, 2 hours at X, Y and 4 hours at Z JIS D 1601 as standard 30 G, 3 times at X, Y, Z IP50 (IEC standard) Maximum transmission distance Position detection method Magnetic field

Incremental type 14.5 mT 10.8 to 13.2 VDC (Ripple less than 1%) 40 mA 0.1 mm/pulse 0.2 mm Note) (at 20C) NPN open collector (35 VDC, 80 mA) A/B phase difference output 500 VDC, 50 M or more (between case and 12E) 33.3 Hz, 2 hours at X, Y and 4 hours at Z JIS D 1601 as standard 30 G, 3 times at X, Y, Z IP50 (IEC standard) Maximum transmission distance Position detection method Magnetic field

Yaw moment M3 = W4 x L2 YES L2 Is there any influence of noise? (Refer to Caution on Handling on pages 706 and 707.) Install a noise filter. NO M3 There is no particular problem in using the system.

Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 mA or less 2.5 to 40 mA Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less Leakage current 100 A or less at 24 VDC 0.8 mA or less Indicator light Operating range Red LED lights up.

Mist generation pressure differential (MPa) IC EX: How to obtain the mist generating pressure differential if the flow rate obtaine in 1. above is 35 m3/min and the line pressure (inlet pressure P1) is 0.7 MPa: Extend horizontally from the point at which the flow rate is 35 m3/min to obtain the point that intersects with P1 = 0.7 MPa.

LEF Auto switch model D-M9NV D-M9N D-M9B D-M9BV D-M9PV D-M9P Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular LEJ Wiring type 2-wire 3-wire NPN PNP Output type LEL Applicable load IC circuit, Relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) LEM Current consumption 10 mA or less Load voltage 24 VDC (10 to 28 VDC) 28

End Plate EX600-ED2-l EX600-ED3-l Power connector Model specification M12 (5-pin) plug 7/8 inch (5-pin) plug 24 VDC 10%, Class 2, 2 A 24 VDC 10%, 8 A Power supply (for Control/Input) Power supply (for Output) 24 VDC +10/5%, Class 2, 2 A 24 VDC +10/5%, 8 A Enclosure IP67 (Manifold assembly) Standards CE marking, UL (CSA), RoHS recognition Weight 0.4 lbs (170 g) 0.4 lbs (175 g) EX600-ED3-l

Note) 2 position single 1 2 Note) 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC G: Grommet C kit single only.

12 VDC 6 VDC 5 VDC 3 VDC ZH Output specifications (Vacuum switch) ZU Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com NPN open collector, single output Analog, no output, 3 turn setting 14 ZL Note 1) The serial transmission type is 5 (24 VDC) only.

2 1 + A DC circuit AC circuit 1 1 (+, ) Round head combination screw M3 Tightening torque 0.5 to 0.6 Nm SOL.

: 5 Pilot valve assembly VQZ111P: Coil rated voltage Example) 24 VDC: 5

Cable core wire colors Brown: 24 VDC (for solenoid valve) White: 0 V (for solenoid valve) Blue: 24 VDC (for control and input) Black: 0 V (for control and input) Gray: Not connected Terminal no.