l 151 to 200 h Bore size (mm) e f 1 to 50 25 25 25 25 25 25 51 to 100 37.5 37.5 37.5 37.5 37.5 37.5 101 to 150 50 50 50 50 50 50 201 to 300 100 100 100 100 100 100 301 to 400 125 125 125 125 125 125 401 to 500 150 150 150 150 501 to 600 175 175 601 to 700 187.5 187.5 701 to 750 73 81 89 89 101 101 1 to 50 86 94 102 102 114 114 51 to 100 98 106 114 114 126 126 101 to 150 111 119 127 127
Standard type 1.0 5 to 35 HRSH090 Inverter type 0.1 5 to 40 Indoor use (400 V as standard, 200 V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 (400 V as standard, 200 V as an option) (Only 200 V as an option) CH1 0.1 15 to 25 HRL Inverter dual type 26 kW Indoor use 19 kW 9 kW CH2 0.5 20 to 40 1.0 kW (Max. 1.5 kW) 322 Circulating Fluid
Standard type 1.0 5 to 35 V V HRSH090 Inverter type 0.1 5 to 40 V Indoor use (400 V as standard, 200 V as an option) (Only 200 V as an option) Outdoor installation IPX4 HRSH Inverter type 0.1 5 to 35 V V V V V (400 V as standard, 200 V as an option) (Only 200 V as an option) Indoor use Electrical box: IPX4 CH1 0.1 15 to 25 V HRLE Basic dual type V (CH1, 2 (CH1, 2 Scheduled to acquire UL
S n Auto switch Without auto switch (Built-in magnet) Nil Bore size (Stroke (mm)) For the applicable auto switch model, refer to the table below. 8 12 16 20 25 25, 50, 75, 100, 125, 150 50, 75, 100, 125, 150 75, 100, 125, 150, 175, 200 100, 125, 150, 175, 200, 225, 250 100, 125, 150, 175, 200, 225, 250, 275, 300 Option Nil Standard (with urethane bumper) With shock absorbers 2 pcs.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Bore size (Stroke (mm)) 8 12 16 20 25 25, 50, 75, 100, 125, 150 50, 75, 100, 125, 150 75, 100, 125, 150, 175, 200 100, 125, 150, 175, 200, 225, 250 100, 125, 150, 175, 200, 225, 250, 275, 300 Auto switch Nil Without
AI RLQ AM W Cutout window MLU View A-A' MLGP Mounting dimensions Standard Stroke ML1C (mm) A AA AB AG AH AI AJ AK AL AM AN AO AP B BP Note 3) BZ GC GD GK Bore size (mm) 20 25 32 40 Stroke range (mm) 75, 100, 125, 150, 200 94 12 13 134 150 92 108 9 9 75 140 M8 32 135 1/8 73.5 28 54 3.5 104 16 16 160 176 110 125 9 9 88 165 M8 37 160 1/8 86.5 29 62 4 75, 100, 125 150, 200, 250 300 104 16 16
, 175, 200, 250, 300, 350 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 RLQ Manufacture of Intermediate Stroke MLU ML1C Spacer installation type Spacers are installed in the standard stroke cylinders. 20 to 32: Stroke can be modified by the 1 mm interval. 40 to 100: Stroke can be modified by the 5 mm interval.
, 175, 200, 250, 300, 350 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 RLQ Manufacture of Intermediate Stroke MLU ML1C Spacer installation type Spacers are installed in the standard stroke cylinders. 20 to 32: Stroke can be modified by the 1 mm interval. 40 to 100: Stroke can be modified by the 5 mm interval.
(The motor full load current is 115 rated current.) 1000 1000 In operation In operation 100 100 Operation time [s] Operation time [s] In servo lock In servo lock 10 10 1 1 0.1 100 200 300 400 0 0.1 100 200 300 350 0 50 150 250 350 50 150 250 (Note 1, 2, 3) Load ratio [ ] (Note 1, 2) Load ratio [ ] LECSB-S5 LECSB-S7, LECSB-S8 Note 1.
Note 2) When the valve is a standard (dustprotected) specification, it is not compatible with 200 or 220 VAC.
16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Minimum Strokes for Auto Switch Mounting Refer to p.1.3-57.
170 (6.00) 240 (8.48) 300 (10.59) IDG30LM IDG50LM IDG60LM IDG75LM IDG100LM 50 (1.77) 100 (3.53) 150 (5.30) IDG60SM IDG75SM IDG100SM V type A regulator combined with the M type 25 (0.88) 50 (1.77) 100 (3.53) 200 (7.06) 300 (10.59) 500 (17.66) 600 (21.19) 750 (26.49) 1000 (35.31) IDG3V IDG5V IDG10V IDG20V IDG30V IDG50V IDG60V IDG75V IDG100V 25 (0.88) 50 (1.77) 100 (3.53) 200 (7.06) 300 (10.59
CC 25, 50, 75, 100 125, 150, 175, 200 M L MVGQ 80/100 RB Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.
, 200 20 25 32 40 50 63 80 100 20 25 32 40 50 63 80 100 1/8 Relief type Vacuum suction type 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 Non-lube Double acting, Up to 1500 25, 50, 75, 100, 125, 150, 200 Single rod (40 to 63) 1/8 25, 50, 75, 100, 125, 1/4 150, 200, 250, 300 3/8 1/2 Note 1) When exceeding the standard strokes above, the particle generation class may not be satisfied
5 300 200 LEY32 Motor mounting position: Top/Parallel 200 W /60 (Motor rotation speed) (3600 rpm) (2400 rpm) A 16 1000 640 B 8 500 320 C 4 250 160 LEY32D Motor mounting position: In-line 200 W /60 (Motor rotation speed) (3750 rpm) (2400 rpm) A 20 1000 800 600 500 B 10 500 400 300 250 C 5 250 200 150 125 LEY63 Motor mounting position: Top/Parallel, In-line 400 W /60 (Motor rotation speed
10, 20, 30, 40, 50, 75, 100 125, 150, 175, 200 For long strokes, it will be made-to-order.
Rod type / LEY Series 2.1 Specification LEY63 (Top/Parallel) LEY32 LEY32D Model LEY25 (Top/Parallel) / LEY25D(in-line) (Top/Parallel) (in-line) LEY63D (in-line) 30, 50, 100, 150, 200, 30, 50, 100, 150, 200, 30, 50, 100, 150, 200, 100, 200, 300, 400, 500, 600, 250, 250, 250, Stroke[mm] 700, 800 300, 350, 400, 500 300, 350, 400, 500 300, 350, 400 Horizontal Note 1) 18 50 50 30 60 60 30 60 60
Main circuit of switch MSM022P1A 200 Output Black lead wire 200/230 MSD023P1E 100/115 MR-C20A1 Mitsubishi Electric Corporation HC-PQ23 200 200/230 MR-C20A 100/115 SGDE-02BP 200 SGME-02BF12 Yaskawa Electric Corporation Blue lead wire 200/230 SGDE-02AP SGME-02AF12 H S For motor mounting dimensions, refer to the dimensions for series LJ1 30 on page 143 as a reference for mounting and design
200 250 0 0 50 100 150 200 Flow rate L/min (ANR) Flow rate L/min (ANR) ARM5AA1-308 (One-touch fittings: IN/OUT 6) Condition: Inlet pressure 0.7 MPa ARM5AA1-308-1 (One-touch fittings: IN/OUT 6) Condition: Inlet pressure 0.5 MPa 0.7 0.35 0.6 0.30 0.5 0.25 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0 0 50 100 150 200 250 0 0 50 100 150 200 250 Flow rate L/min (ANR) Flow rate L/min (ANR) ARM5AA1-309
Contents 150 NC1AKW150-PS 200 NC1AK200-PS-XC11 200 NC1AKW200-PS 250 NC1AKW250-PS