Note 2) For interface use, supply 24 VDC o10% 150 mA using an external source. Note 3) The failure (ALM) is ON during normal conditions.
/N.O. 10-SV3000 Double solenoid 102 2(B) 4(A) 2(B) 4(A) 3 position 110 Single solenoid 186 10-SV4000 Double solenoid 190 1(P) 5(EA) 3(EB) 5(EA) 3(EB) 1(P) 3 position 211 N.C./N.O. N.C./N.O.
The following graphs show overload protection characteristics. 1000 1000 Operating Operating Operating 100 100 Operation time [s] Operation time [s] Servo-lock Servo-lock 10 10 1 1 0.1 0.1 350 100 200 300 400 0 50 150 250 350 100 200 300 350 0 50 150 250 Load ratio [%] (Note 1, 2, 3) ) (Note 1, 2) Load ratio [%] LECSC2-T7, LECSC2-T8, LECSC2-T9 LECSC2-T5 Note1.
Note 2) For interface use, supply 24 VDC 10% 150 mA using an external source. Note 3) The failure (ALM) is ON during normal conditions.
Wn Y Y-axis Yn Z-axis Zn X-axis Xn X Wa 65 mm 0 mm 5 mm 0.88 kg 210 65 150 111 Z Wb 150 mm 0 mm 42.5 mm 4.35 kg Wc 150 mm 111 mm 42.5 mm 0.795 kg Wd 150 mm 210 mm 42.5 mm 0.5 kg Y 42.5 5 n = a, b, c, d 3.
ML2B C J G5-S CV MVGQ CC RB J D-X 20Data 10-14-3 4 Stainless Steel Cylinder Series CJ5-S 10, 16 How to Order Bore size Standard stroke (mm) 10 16 10 16 10 mm 16 mm 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes by the 1 mm interval are available without using spacers for stroke adjustment.
The spacing of the side support must be no more than the values shown in the graphs at right. 200 200 190 190 (2100) (2100) (2100) 180 180 170 170 160 160 m 150 150 140 140 (2400) (2400) (2400) (2400) (2400) 130 130 l (1800) (1800) (1800) 120 120 Weight m (kg) Weight m (kg) 110 110 MY1MW63 MY1MW63 100 100 (2000) (2000) (2000) (2000) (2000) 90 90 (1500) (1500) (1500) MY1CW63 MY1CW63 m 80 80
ML2B C J G5-S CV MVGQ CC RB J D-X 20Data 10-14-3 4 Stainless Steel Cylinder Series CJ5-S 10, 16 How to Order Bore size Standard stroke (mm) 10 16 10 16 10 mm 16 mm 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes by the 1 mm interval are available without using spacers for stroke adjustment.
Igm: Leakage current of the servo motor (Found from Table 13.4.) 120 120 100 100 Leakage current Leakage current 80 80 60 60 40 40 [mA] [mA] 20 20 0 2 0 14 100 5.5 38 2 3.5 8 1422 38 80 150 5.5 30 60 100 3.5 8 22 60 150 30 80 Cable size[mm2] Cable size[mm2] a. 200V class b. 400V class Fig. 13.4 Leakage current example (lg1, lg2) for CV cable run in metal conduit 13 26 13.
150 50 100 200 50 100 200 0 (1N = Approx. 0.102kgf) Load N (1N = Approx. 0.102kgf) Load N Load N (1N = Approx. 0.102kgf) 20 20 20 Lr = 160mm MXQ20-150 MXQ20-125 0.08 MXQ20-10 MXQ20-20 MXQ20-30 MXQ20-40 MXQ20-50 0.12 MXQ20-40 MXQ20-40 MXQ20-75 MXQ20-75 MXQ20-75 MXQ20-30 0.06 Table displacement mm Table displacement mm Table displacement mm 0.06 MXQ20-100 MXQ20-125 MXQ20-150 MXQ20-50 MXQ20
5 121 130 4 101 110 3 81 90 2 61 70 L1 L2 Insert plug with lead wire: VV5ZS2-51GStation 1Port size 2-4.5 mounting hole Manual override 2n-Rc 1/8, 1/4 Indicator light U side (n) (2) (1) Stations D side 2-C6, C8 A 2 B 10.7 31.5 (Port size: One-touch fitting type) (Electrical entry) n: Stations L Stations Formula 20n + 21 20n + 30 2 61 70 3 81 90 4 101 110 5 121 130 6 141 150 7 161 170 8 181
150 150 Long Stroke Slide Table MXW Series Dimensions MXW 20 Stoke: 150, 175, 200, 225, 250 (mm) Operating port 2-Rc (PT) 1/8 Width across hexagon socket hole 4 J 20 Scale: 20% 10 Width across flats 13 8-M5 x 0.8 thread depth 13 (Helisert) 6H9 +0.03 depth 5.5 6H9 +0.03 depth 5.5 0 0 7 72 98 48 Y Y 25 160 40 40 40 L 11 24 24 K A 60 50 32.5 Z A N-M6 x 1 thread depth 12 (N-1) x H G Bottom
6 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 RDP (8) (2) 150 RDN 7 7 7 7 7 7 8 8 8 8 8 8 6 6 6 (6) (6) (6) 1.
Internal wiring 1 3 5 6 01 C6 C8 VZ523MOZ-VZ3Applicable solenoid valve 100 VAC 50/60 Hz, 110 VAC 50/60 Hz, 24 VDC, 12 VDC Rated voltage Note) Withstand voltage specification of wiring unit part is equivalent to JIS C 0704 class 1.
70 40 50 12 5.5 190 185 50 63 50 25 12 170 16 20 190 40 80 9 90 70 16 10 100 120 80 50 63 14 6.5 215 210 63 80 63 30 16 190 16 20 210 50 100 12 110 90 16 12 126 153 100 60 100 120 75 35 16 205 14 20 140 25 230 110 60 20 75 16 6.5 230 220 71 14.5 150 178 120 6-13-10 10 Series CP95 ISO/VDMA Cylinder: Standard Type Double Acting w/ End of Stroke Cushioning Dimensions: Cylinder Mounting Accessory
40 50 12 5.5 190 185 50 63 50 25 12 170 16 20 190 40 80 9 90 70 80 16 10 100 120 50 63 14 6.5 215 210 63 80 63 30 16 190 16 20 210 50 100 12 110 90 100 16 12 126 153 60 100 120 75 35 16 205 14 20 140 25 230 110 60 120 20 75 16 6.5 230 220 71 14.5 150 178 6-13-10 10 Series CP95 ISO/VDMA Cylinder: Standard Type Double Acting w/ End of Stroke Cushioning Dimensions: Cylinder Mounting Accessory
-18-150 JA80-22-150 JA100-26-150 JA140-30-150 JA160-36-150 6 10 (CJ1) 10 (CZ1), 15 (CJ1) 15 (CZ1) 20 25, 32 40 50, 63 80 100 125, 140 160 3 4 5 6 8 10 14 18 22 26 30 36 0.5 0.7 0.8 1 1.25 1.25 1.5 1.5 1.5 1.5 1.5 1.5 15 17 23 23 30.5 34 38 47.5 56.5 68 94.5 112 23.2 26 34.5 34.5 44 49.5 60 74.5 89.5 110 152 178 7 9 12.5 12.5 17.5 19.5 20 25 29 35 42 52 8 10 14 14 45 55 12 12 16 16 21 24 31
Position loop P constant A 140 110 110 1 to 200 B 100 80 80 C 110 80 80 H 80 140 140 Sets the speed loop P constant. *Please perform the actuator operation after changing this parameter setting under the responsibility of the user. Speed loop P constant A 110 140 140 1 to 200 B 120 75 100 C 150 120 120 H 50 80 80 Sets the speed loop I constant.
Then, the charging time (T) for a 100l tank, V 10 T = t x = 110 x = 110(s). 10 10 T = t x = 49 x = 49(s). 10 10 V 10 T = t x = 12.4 x = 24(s). 100 10 V 10 1.13-2 VBA1110 to 4200 Size Selection Pulsation is decreased by using tank. If secondary capacity is undersized, pulsation may occur.
PF2A703H--28 PF2A703H--68 PF2A706H--28 PF2A706H--68 PF2A703H--29 PF2A703H--69 PF2A706H--29 PF2A706H--69 3000 150 3000 150 6000 300 6000 300 PF2A712H--28 PF2A712H--68 PF2A712H--29 PF2A712H--69 12000 600 12000 600 16-11-16 13 For details about certified products conforming to international standards, visit us at www.smcworld.com.