Principal Parts Material Body C3604BD, Flame resistant PBT (UL-94 standard V-0) C3604BD (Thread portion) Stainless steel 304 Stainless steel 304, Flame resistant PBT (UL-94 standard V-0) POM Stud Chuck Guide Collet Release button Seal, O-ring Flame resistant PBT, Flame resistant CR (UL-94 standard V-0) Cover (Option) Flame resistant PBT (UL-94 standard V-0) NBR 15-3-1 2 Series KR Model Male
New Products Guide 2 Air Preparation Equipment, Modular F. R. L., Air Tanks Fittings and Tubing Flow Control Equipment, Exhaust Filters Switches/Sensors Process Valves High Vacuum Equipment Temperature Control Equipment Pneumatic Instrumentation Process Gas Equipment Equipment CAT.E00-7A INDEX New Products Guide 2 Air Preparation Equipment/ Modular F. R. L./Air Tanks Refrigerated Air Dryer
M1 M2 M3 Cp, Cy Cr 0.046 0.040 0.049 28.3 5 0.046 0.040 0.049 28.3 10 Caution 0.061 0.053 0.062 31.5 15 MXU6 7.5 1. Do not place your fingers in the clearance between the table and the cylinder tube. Your fingers could get caught between the table and the cylinder tube when the piston rod retracts.
Flame resistant PBT (UL standard V-0) Flame resistant type Cover Flame resistant CR Knob: 2 port valve: Gray 3 port valve: Blue 2/3 port valve: Red (Option) Cam ring POM POM Stem Flame resistant CR (UL standard V-0) For flame resistant type with cover only Spring guide 3(R) Exhaust 3(R) Exhaust Stainless steel Spring NBR Packing, O-ring, Valve 5-8-1 Series VHK How to Order 2 VHK R L 02S 02S
Material Body material 316L SS secondary remelt Ni-Cr-Mo alloy 2) Seat material Code Surface finish S H Code Material PCTFE (Standard) Polyimide 3) Surface finish Ra max Code No code VS 2) Special export controls apply to Ni-Cr-Mo alloy body with 1/2 inch or greater size connection. 15 in. (0.4 m) Standard 10 in. (0.25 m) No code M 3) Not available with H material.
LECSB Positioning unit 24 VDC Note 2) Note 4) CN1 QD75D (Manufactured by Mitsubishi Electric) Note 4) 21 DICOM CN1 Failure Note 3) DICOM 20 48 ALM RA1 CLEARCOM 14 DOCOM 46 Zero speed detection 23 ZSP RA2 CLEAR 13 CR 41 Torque limiting RDYCOM 12 25 TLC RA3 Positioning completion READY 11 RD 49 24 INP RA4 PULSE F+ 15 PP 10 PULSE F 16 PG 11 10 m or less NP 35 PULSE R+ 17 S/S NG 36 PULSE R 18
(Example) Bolt M5 x 110 L (Two bolts are necessary per cylinder) Rod side mounting Head side mounting CH CR Flat washer for RZQB D D C 50, 63 Note) Use the attached washer when inserting the bolt from the rod side. RZQB Mounting Bolt CH CR C D Cylinder model Mounting bolt size No. of bolts Attached flat washer part no.
TB TN Td TE TF TH TT TR 3.2 3.2 4.5 4.5 6 8 11 12 8 10 12 14 16 18 18 22 CG-020-24A CG-025-24A CG-032-24A CG-040-24A CG-050-24A CG-063-24A CG-080-24A CG-100-24A 20 25 32 40 50 63 80 100 25 30 35 40 50 60 55 65 36 43 50 58 70 82 73 90 (29.3) (33.1) (40.4) (49.2) (60.4) (74.6) 28 01 13 15 17 21 24 26 36 50 10 10 10 10 20 20 5.5 5.5 6.6 6.6 9 11 11 13.5 CR CN CD SLOT CC(20mm-40mm) 03 32 01
Example) AF30-03BD-CR-A q r t w e q Symbol 20 30 40 Body size Description Nil N Note 1) Rc NPT G F Note 2) Thread type w + 01 02 03 04 06 1/8 1/4 3/8 1/2 3/4 Port size e + Nil B Note 3) Mounting a Without mounting option With bracket Option Semi-standard + r Nil C Note 4) D Note 5) Float type auto drain b Without auto drain N.C.
DICOM 1 Failure Note 3) 9 ALM RA1 N OPC 2 12 MBR RA2 Electromagnetic brake interlock DOCOM 13 S/S Y000 PP 23 COM1 Y010 NP 25 10 m or less COM3 15 LA A phase pulse detector (Differential line driver) Y004 CR 5 16 LAR COM2 17 LB B phase pulse detector (Differential line driver) 18 LBR Xmmm INP 10 19 LZ Z phase pulse detector (Differential line driver) 20 LZR Xmmm Control common 14 LG RD 11
LECSB Positioning unit QD75D (Manufactured by Mitsubishi Electric) 24 VDC Note 2) Note 4) Note 4) CN1 21 DICOM CN1 Failure Note 3) DICOM 20 48 ALM RA1 Zero speed detection CLEARCOM 14 DOCOM 46 23 ZSP RA2 CLEAR 13 CR 41 Torque limiting RDYCOM 12 25 TLC RA3 Positioning completion READY 11 RD 49 24 INP RA4 PULSE F+ 15 PP 10 PULSE F 16 PG 11 10 m or less NP 35 17 PULSE R+ PULSE R S/S NG 36 4
Material: S (Body: 316L SS Secondary Remelt; Poppet: Ni-Cr-Mo Alloy; Diaphragm: Ni-Cr-Mo Alloy; Nozzle: 316L SS), Surface Finish: M [10 μin. (0.25 μm)], Ports: 2PW [2 Ports (1-In; 2-Out)], Connections, Inlet: MV4 (1/4 Inch Face Seal, Male), Connections, Outlet: MV4 (1/4 Inch Face Seal, Male), Gauge Port, Inlet: No Gauge Port, Gauge Port, Outlet: No Gauge Port, Pressure Gauge Unit: psig/
Material: S (Body: 316 SS; Poppet: Ni-Cr-Mo Alloy; Diaphragm: Ni-Cr-Mo Alloy; Nozzle: 316 SS), Ports: 3P, Connections, Inlet: 8 (NPT 1/2 inch), Connections, Outlet: 8 (NPT 1/2 inch), Gauge Port, Extra Bottom Outlet: 2 [0 to 200 psig (0 to 1.4 MPa)], Gauge Port, Inlet: No Gauge Port, Gauge Port, Outlet: No Gauge Port, Pressure Gauge Unit: psig/bar (or None in the Case of No Gauge), Seat Material
CR Clear When this is turned ON, droop pulse is eliminated.
DOGDOGOFF Z (CR) () DOG LECSS2T [Pr. PA10] DOGDOG DOG DOG DOG LECSS2T ([Pr. PA09]) 1( ) [Pr. PA10] X1 8 63 8.
Data is "P+0" (CR) or "P-0" (CR) when the number of revolutions is zero. 2. The revolution range is "-32768" to "+32767". When this range is exceeded, the data changes from "+32767" to "-32678" or from "-32678" to "+32767". When changing multiturn limit, the range changes. For details, refer to 4.7.5 Multiturn Limit Setting.
Data is "P+0" (CR) or "P-0" (CR) when the number of revolutions is zero. 2. The revolution range is "-32768" to "+32767". When this range is exceeded, the data changes from "+32767" to "-32678" or from "-32678" to "+32767". When changing multiturn limit, the range changes. For details, refer to 4.7.5 Multiturn Limit Setting.
50 63 71 7 10 10 10 12 14.5 17 22 22 28 34 40 73 82.5 90 97.5 110 120 95 106.5 122 129.5 150 160 12 16 16 20 20 25 12 16 16 20 20 25 50 63 75 90 110 132 49 58 71 87 110 136 64 72 90 100 126 150 79 90 110 120 153 178 50 55 70 80 100 120 32 40 50 63 80 100 6-12-8 Series C95 ISO/VDMA Cylinder: Standard Type Double Acting, Single/Double Rod Dimensions: Cylinder Mounting Accessory C, D, E and CR
Auto switch Without auto switch (Built-in magnet) Nil Action D S C Double acting Single acting (Normally open) Single acting (Normally closed) Dust cover material Nil F S Chloroprene rubber (CR) Fluororubber (FKM) Silicon rubber (Si) Finger material Nil 1 Carbon steel Stainless steel Applicable Auto Switch/Refer to pages 761 to 809 for further information on auto switches.
89 41 5 25 10 55 20 20 11 12 115 110 60 Mounting type E Bore d2 CK S5 K1 K2 l3 G1 l1 G2 EM G3 CA H6 R1 32 11 10 6.6 38 51 10 21 7 18 26 31 32 8 10 40 11 12 6.6 41 54 10 24 9 22 28 35 36 10 11 50 15 12 9 50 65 12 33 11 30 32 45 45 12 12 63 15 16 9 52 67 14 37 11 35 40 50 50 12 15 80 18 16 11 66 86 18 47 12.5 40 50 60 63 14 15 100 18 20 11 76 96 20 55 13.5 50 60 70 71 15 19 Mounting type CR