SMC Corporation of America
Elite Part Number Search
Search Results "RLQD50TN-75-BR"

<br>Note) The KK□ series S coupler cannot be used as a stop valve that requires zero leakage. Due to the specifications of the product, a certain amount of leakage is unavoidable.<br><br>

<br><br>Meter-in control is a control method in which the speed of the cylinder is controlled using the cylinder supply flow rate.<br>With meter-in control, the exhaust conditions do not affect operation, and the piston can start moving quickly. (Cylinder lurching can be prevented.)

<br>Be sure to check the specifications and precautions listed in the catalog of each type of tubing and fitting. <br>Note that LQ series piping requires a special tool. <br><br><br><br>Fittings and tubing catalogs can be found here.

<br>First, refer to the “Transport and Setting Up” section in the HRS series operation manual. <br>Wiring examples are shown in the “Wiring of remote operation signal input” and “Wiring of run/stop signal input・Remote signal input” sections. <br>Next, to enable remote signal input, change the communication mode from “LOCAL” to “DIO” mode.

<br>Please check the figure below. If the product is equipped with a control power supply, this control power supply circuit is provided. <br>If the operating power supply voltage is energized while the valve is open, it is acceptable not to drop it to the holding voltage.<br><br>

<br><br>・While it is possible to mount a G36-10-01 or G46-10-01 pressure gauge on a VEX113□/123□ series regulator, it will be larger than the width of the product body.<br>・It is also possible to mount a G46-10-01 pressure gauge on a VEX133 □ series regulator so long as it does not interfere with the piping.

<br>“VVFS2000-22A-1” is the plug-in type perfect spacer part number for the VFS2600.<br>And “VVFS2000-22A-2” is the non plug-in type perfect spacer part number for the VFS2610.<br>The “□” in the VVFS□000-22A-1 and VVFS□000-22A-2 part numbers is to indicate the series (VFS2000/3000/4000/5000 series).<br><br>

<br>Reference) The manifold specification (a VOA301 valve and a VVTA300 base) of the air operated VTA301 series valve can also be changed to from N.C to N.O. by turning over the switching plate in the same way.<br><br>

<br>VS4120, VS4130, and VS3135 series valves with a grommet have 2 lead wires.<br>Connections: For 100 VAC, there are 2 blue wires. For 200 VAC, there are 2 red wires. And for 24 VDC, there is 1 white wire and 1 pink wire.<br>VS4140 and VS3145 series valves have 3 lead wires for AC voltage types and 2 lead wires for DC voltage types.