<br>Note) The accuracy will decline if IN side piping deviating from the recommended straight piping length or bore size is used.<br><br>
<br>The VX3 series catalog can be found here.<br><br>
<br>Be sure to check the specifications and precautions listed in the catalog of each type of tubing and fitting. <br>Note that LQ series piping requires a special tool. <br><br><br><br>Fittings and tubing catalogs can be found here.
<br>In this case, use the bypass piping set (optional accessory) to secure the flow rate. <br>Note) The temperature stability is as follows: ±2.0℃ for the HRSE, ±0.5℃ for the HRS090, and ±1.0℃ HRS100/150/200.<br><br>
<br>First, refer to the “Transport and Setting Up” section in the HRS series operation manual. <br>Wiring examples are shown in the “Wiring of remote operation signal input” and “Wiring of run/stop signal input・Remote signal input” sections. <br>Next, to enable remote signal input, change the communication mode from “LOCAL” to “DIO” mode.
<br>Please check the figure below. If the product is equipped with a control power supply, this control power supply circuit is provided. <br>If the operating power supply voltage is energized while the valve is open, it is acceptable not to drop it to the holding voltage.<br><br>
<br><br>・While it is possible to mount a G36-10-01 or G46-10-01 pressure gauge on a VEX113□/123□ series regulator, it will be larger than the width of the product body.<br>・It is also possible to mount a G46-10-01 pressure gauge on a VEX133 □ series regulator so long as it does not interfere with the piping.
<br>Note) The all side piping option was only added to the VH200 series (as described in ②) in 2016. The VH series catalog can be found here<br><br>
<br><br>For plug lead type manifolds:<br>The max. number of stations that can be increased depends on the wiring kit.
<br>“VVFS2000-22A-1” is the plug-in type perfect spacer part number for the VFS2600.<br>And “VVFS2000-22A-2” is the non plug-in type perfect spacer part number for the VFS2610.<br>The “□” in the VVFS□000-22A-1 and VVFS□000-22A-2 part numbers is to indicate the series (VFS2000/3000/4000/5000 series).<br><br>
<br>Note) A cylinder with a lock may be required depending on the operating conditions.
<br><br>Non plug-in type:<br>Electrical connection is made on the solenoid valve side. Electrical connection is required when replacing the solenoid valve.
<br>Reference) The manifold specification (a VOA301 valve and a VVTA300 base) of the air operated VTA301 series valve can also be changed to from N.C to N.O. by turning over the switching plate in the same way.<br><br>
<br>VS4120, VS4130, and VS3135 series valves with a grommet have 2 lead wires.<br>Connections: For 100 VAC, there are 2 blue wires. For 200 VAC, there are 2 red wires. And for 24 VDC, there is 1 white wire and 1 pink wire.<br>VS4140 and VS3145 series valves have 3 lead wires for AC voltage types and 2 lead wires for DC voltage types.
<br><br>The VSA4□20, VSA4□30, and VSA4□40 series catalogs can be found here.
<br>(They are matched to the individual component dimensions.)<br>Coils of VT317 (VO317) series valves, however, can be ordered, excluding CE-compliant products with the part number suffix “-Q.” Refer to the catalog for the coil assembly part numbers.<br>Do not use coils for DC in valves whose rated voltage is AC, and vice versa.
<br><br>
<br><br>For further details, refer to the catalog of each series.